NextSDS Logo
Safety Data Sheet EN

LOCTITE HHD 8540BK DC50ML PTA

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE HHD 8540BK DC50ML PTA
Product Code
2731591

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Acrylic Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2
Skin Irrit. Cat. 2
Eye Dam. Cat. 1
Skin Sens. Cat. 1
STOT SE Cat. 3

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H225 HIGHLY FLAMMABLE LIQUID AND VAPOR.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H318 CAUSES SERIOUS EYE DAMAGE.
H335 MAY CAUSE RESPIRATORY IRRITATION.

Precautionary Statements

P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P233 Keep container tightly closed.
P233 Keep container tightly closed.
P235 Keep cool.
P241 Use explosion-proof equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P261 Avoid breathing vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P273 No release into water.
P280 Wear protective gloves, eye protection, and face protection.
P304 + P341 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P312 Call a POISON CENTER or physician if you feel unwell.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P361 If on skin (or hair): Take off immediately all contaminated clothing.
P362 Take off contaminated clothing.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 Store in a well-ventilated place.
P403 Store in a well-ventilated place.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Methyl methacrylate 80-62-6 30 - 60% Yes
Methacrylate ester --- 10 - 30% Yes
methacrylic acid 79-41-4 5 - 10% Yes
Silica, amorphous, fumed, crystal-free 112945-52-5 1 - 5% Yes
Methacrylate ester --- 0.1 - 1% Yes
Triphenylphosphine 603-35-0 0.1 - 1% Yes
Carbon black 1333-86-4 0.1 - 1% Yes
Organophosphorus compound --- 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. If symptoms develop and persist, get medical attention.

Skin contact

Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, dry chemical or carbon dioxide.

Specific hazards

Vapors may accumulate in low or confined areas, travel considerable distance to source of ignition, and flash back. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. During use and until all vapors are gone: Keep area ventilated - do not smoke; extinguish all flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources of ignition. Keep container closed.

Storage

Store between 2 °C (35.6 °F) and 8 °C (46.4 °F). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight. Maintain head space in storage containers to support oxygen requirements of the inhibitor(s).

Fire prevention

Keep area ventilated - do not smoke; extinguish all flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources of ignition. Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Black
Colour Intensity
---
Form
---
Odor
Acrylic
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
< 23 °C (< 73.4 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
0.98
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
Not available.
Solubility In Fat
---
Molecular Weight
---
Voc Content
54.3 %
Metal Corrosion
---
Dynamic Viscosity
30,000 mPa.s
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Polymerization may occur at elevated temperatures or upon depletion of inhibitor.

Avoid

Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight. Loss of polymerization inhibitor. Loss of dissolved air. Do not mix in batches greater than 100 grams (0.22 pounds) unless you plan to use immediately.

Incompatible

Bases. Acids. Reducing agents. Oxidizing agents. Free radical initiators. Peroxides.

Decomposition

Oxides of carbon. Oxides of nitrogen. Hydrogen cyanide. Toxic fumes. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1133
Shipping Name
Adhesives
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE HHD 8540BK DC50ML PTA?

The signal word is danger.

What is the physical form of LOCTITE HHD 8540BK DC50ML PTA?

LOCTITE HHD 8540BK DC50ML PTA is a liquid with black color. It has acrylic odor.

What is LOCTITE HHD 8540BK DC50ML PTA used for?

Acrylic Adhesive

What are the hazard statements for LOCTITE HHD 8540BK DC50ML PTA?

This substance has 5 hazard statements:

  • H225: HIGHLY FLAMMABLE LIQUID AND VAPOR.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H318: CAUSES SERIOUS EYE DAMAGE.
  • H335: MAY CAUSE RESPIRATORY IRRITATION.

What is the melting point of LOCTITE HHD 8540BK DC50ML PTA?

The melting point is Not available. and the boiling point is Not available..