NextSDS Logo
Safety Data Sheet EN

AQUENCE EPIX BC 6134CN 50KG

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AQUENCE EPIX BC 6134CN 50KG
Product Code
2916636

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

Wash affected area immediately with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

If material is ingested, immediately contact a physician or poison control center. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

If symptoms develop and persist, get medical attention.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Unsuitable media

Not available.

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

Keep unnecessary personnel away.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Small spill

Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers.

Large spill

For large spills dike ahead and collect liquid.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers. For large spills dike ahead and collect liquid.

Materials: vermiculite, clay or other suitable non-biodegradable absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash thoroughly after handling. Use only with adequate ventilation. Avoid contact with eyes, skin and clothing. Do not taste or swallow. Keep container closed. Do not breathe gas/fumes/vapor/spray.

Storage

Keep the container tightly closed and in a cool, well-ventilated place. Protect from freezing, freezing temperature is <=32F (<=0C).

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.

Hands

Use impermeable gloves

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists.

Respiratory

Use NIOSH approved respirator if there is potential to exceed exposure limit(s). Observe OSHA regulations for respirator use (29 CFR 1910.134).

Skin/Body

protective clothing as necessary to prevent skin contact.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Not available.
Form
---
Upper Explosive Limit
Not available.
Decomposition Temperature
Not available.
Cloud Point
---
Physical State
Liquid
Appearance
---
Bulk Density
---
Molecular Weight
---
Flammability
Not applicable
Relative Density
Not available.
Solubility In Fat
---
Partition Coefficient
Not available.
Colour
White
Density
---
Colour Intensity
---
Melting Point
Not applicable, Product is a liquid
Ph
4 - 5
Solidification Point
---
Evaporation Rate
Not determined
Relative Evaporation Rate
---
Properties Status
---
State Under Standard Conditions
---
Flash Point
Not applicable
Auto Ignition Temperature
Not applicable
Boiling Point
100 °C (212°F)
Odor
Specific
Softening Point
---
Kinematic Viscosity
> 20.5 mm2/s
Explosive Limits
---
Voc Content
Not available.
Solubility
Miscible Water
Metal Corrosion
---
Crystallisation Point
---
Physical State Data
liquid
Solubility In Water
---
Vapor Pressure
123.3 mbar (20 °C (68°F))
Vapor Density
---
Dynamic Viscosity
800 - 1,200 mPa.s
Lower Explosive Limit
Not available.
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Freezing conditions.

Incompatible

Avoid contact with materials that are water reactive.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Thermal decomposition can lead to release of irritating gases and vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AQUENCE EPIX BC 6134CN 50KG?

The signal word is no signal word.

What is the physical form of AQUENCE EPIX BC 6134CN 50KG?

AQUENCE EPIX BC 6134CN 50KG is a liquid with white color. It has specific odor.

What is the solubility of AQUENCE EPIX BC 6134CN 50KG?

Miscible Water

What is the melting point of AQUENCE EPIX BC 6134CN 50KG?

The melting point is Not applicable, Product is a liquid and the boiling point is 100 °C (212°F).