NextSDS Logo
Safety Data Sheet EN

LOCTITE EDAG PF 021 150G E&C

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE EDAG PF 021 150G E&C
Product Code
2994928

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Conductive dry film product

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1
Eye Dam. Cat. 1
Skin Sens. Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H314 CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.

Precautionary Statements

P260 Do not breathe vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 If on skin (or hair): Take off immediately all contaminated clothing.
P304 + P340 + P310 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or physician.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Urethane acrylate oligomer~ --- 30 - 60% Yes
Isobornyl acrylate 5888-33-5 10 - 30% Yes
2-Propenoic acid, 2-carboxyethyl ester 24615-84-7 10 - 30% Yes
Acrylic acid 79-10-7 5 - 10% Yes
Benzophenone 119-61-9 0.1 - 1% Yes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. If vomiting occurs, prevent aspiration by keeping the patient's head below the knees. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area. Refer to Section 8 'Exposure Controls / Personal Protection' prior to clean up.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
Not available.
Dynamic Viscosity
11,000 mPa.s
Odor Threshold
Not available.
Molecular Weight
---
Metal Corrosion
---
Freezing Point
---
Vapor Pressure
< 1 hPa (20 °C (68°F))
Ph
Not applicable, Product is non-soluble (in water).
Relative Evaporation Rate
---
Bulk Density
---
Physical State Data
liquid
Properties Status
---
Odor
Characteristic
Solubility In Water
Insoluble
Vapor Density
---
Flammability
Not applicable
Auto Ignition Temperature
Not available.
State Under Standard Conditions
---
Crystallisation Point
---
Partition Coefficient
Not available.
Form
---
Evaporation Rate
1 (Butyl acetate = 1)
Kinematic Viscosity
> 5,000 mm2/s
Colour
Clear
Relative Density
1.103
Density
---
Cloud Point
---
Flash Point
> 93 °C (> 199.4 °F)
Explosive Limits
---
Physical State
Viscous, Liquid
Melting Point
Not applicable, Product is a liquid
Colour Intensity
---
Softening Point
---
Appearance
---
Solubility
Insoluble Water
Solubility In Fat
---
Voc Content
0 g/l
Decomposition Temperature
Not available.
Boiling Point
316 °C (600.8 °F)
Solidification Point
---
Lower Explosive Limit
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight.

Incompatible

Strong oxidizing agents. Strong acids and strong bases.

Decomposition

Oxides of carbon. Oxides of nitrogen. Toxic fumes. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (Isobornyl acrylate, 2-Carboxyethyl acrylate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE EDAG PF 021 150G E&C?

The signal word is danger.

What is the physical form of LOCTITE EDAG PF 021 150G E&C?

LOCTITE EDAG PF 021 150G E&C is a viscous, liquid with clear color. It has characteristic odor.

What is the solubility of LOCTITE EDAG PF 021 150G E&C?

Insoluble Water

What is LOCTITE EDAG PF 021 150G E&C used for?

Conductive dry film product

What are the hazard statements for LOCTITE EDAG PF 021 150G E&C?

This substance has 2 hazard statements:

  • H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.

What is the melting point of LOCTITE EDAG PF 021 150G E&C?

The melting point is Not applicable, Product is a liquid and the boiling point is 316 °C (600.8 °F).