Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE FD 150/6
- Product Code
- 848118
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Wood adhesives
Uses advised against
For industrial use only.
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2,4-Dioxo-1,3-diazetidine-1,3-bis(methyl-m-phenylene) diisocyanate | 26747-90-0 | 1 - 5% | Yes |
| Alcohols, C16-18, ethoxylated 12EO | 68439-49-6 | 0.1 - 1% | Yes |
| acetone | 67-64-1 | 0.1 - 1% | Yes |
| Trimethylolpropane poly(oxypropylene)triamine 5-6PO | 39423-51-3 | 0.1 - 1% | Yes |
IDH number: 848118 Product name: AQUENCE FD 150/6
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.
Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures appropriate to local circumstances and the surrounding environment.
This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.
Keep unnecessary personnel away.
Firefighter Protection
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so.
Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling.
Do not freeze.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Will not occur.
Do not freeze.
Contact with water reactive materials (such as oleum) can cause exothermic reactions.
Oxides of carbon.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE FD 150/6?
The signal word is danger.
What is the physical form of AQUENCE FD 150/6?
AQUENCE FD 150/6 is a liquid with white color. It has neutral odor.
What is AQUENCE FD 150/6 used for?
Wood adhesives
What are the hazard statements for AQUENCE FD 150/6?
This substance has 5 hazard statements:
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H330: FATAL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H351: SUSPECTED OF CAUSING CANCER.
What is the melting point of AQUENCE FD 150/6?
The melting point is Not applicable, Product is a liquid and the boiling point is 100 °C (212°F) no method Aqueous solution.