NextSDS Logo
Safety Data Sheet EN

AQUENCE FD 150/6

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AQUENCE FD 150/6
Product Code
848118

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Wood adhesives

Uses advised against

For industrial use only.

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Carc. Cat. 2
Acute Tox. Cat. 2
Eye Irrit. Cat. 2A
Resp. Sens. Cat. 1
Skin Sens. Cat. 1

GHS Pictograms

GHS06 - Acute toxicity

GHS06

GHS08 - Serious health hazard

GHS08

Hazard Statements

H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H330 FATAL IF INHALED.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
H351 SUSPECTED OF CAUSING CANCER.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P233 Keep container tightly closed.
P261 Do not breathe vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P284 [In case of inadequate ventilation] wear respiratory protection.
P304 + P341 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P310 Immediately call a POISON CENTER or physician.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P352 IF ON SKIN: Wash with plenty of water.
P363 Wash contaminated clothing before reuse.
P403 Store in a well-ventilated place.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2,4-Dioxo-1,3-diazetidine-1,3-bis(methyl-m-phenylene) diisocyanate 26747-90-0 1 - 5% Yes
Alcohols, C16-18, ethoxylated 12EO 68439-49-6 0.1 - 1% Yes
acetone 67-64-1 0.1 - 1% Yes
Trimethylolpropane poly(oxypropylene)triamine 5-6PO 39423-51-3 0.1 - 1% Yes

IDH number: 848118 Product name: AQUENCE FD 150/6

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.

Immediate Medical Attention

Get immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.

Instructions

Keep unnecessary personnel away.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling.

Storage

Do not freeze.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
White
Colour Intensity
---
Form
---
Odor
Neutral
Odor Threshold
Not available.
Ph
7 - 10
Melting Point
Not applicable, Product is a liquid
Boiling Point
100 °C (212°F) no method Aqueous solution
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Same as water.
Vapor Pressure
23.4 mbar (20 °C (68°F)) (aqueous solution)
Vapor Density
< 1 20 °C
Relative Density
1.03
Bulk Density
---
Density
---
Flammability
The product is not flammable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not determined
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
Miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Do not freeze.

Incompatible

Contact with water reactive materials (such as oleum) can cause exothermic reactions.

Decomposition

Oxides of carbon.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AQUENCE FD 150/6?

The signal word is danger.

What is the physical form of AQUENCE FD 150/6?

AQUENCE FD 150/6 is a liquid with white color. It has neutral odor.

What is AQUENCE FD 150/6 used for?

Wood adhesives

What are the hazard statements for AQUENCE FD 150/6?

This substance has 5 hazard statements:

  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H330: FATAL IF INHALED.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
  • H351: SUSPECTED OF CAUSING CANCER.

What is the melting point of AQUENCE FD 150/6?

The melting point is Not applicable, Product is a liquid and the boiling point is 100 °C (212°F) no method Aqueous solution.