Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PUR 3317 BR 12KG
- Product Code
- 3133389
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive for the graphic industry
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,3-Benzenedicarboxylic acid, polymer with 1,4-benzenedicarboxylic acid,2,2-dimethyl-1,3-propanediol, dodecanedioic acid, 1,2-ethane | --- | 80 - 100% | Yes |
| o-(p-Isocyanatobenzyl)phenyl isocyanate | 5873-54-1 | 1 - 5% | Yes |
| 2,2'-Methylenediphenyl diisocyanate | 2536-05-2 | 0.1 - 1% | Yes |
Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.
Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours.
Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.
Symptoms: Molten adhesive may cause severe burns.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
Seek immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Seek immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.
Sealed containers at elevated temperatures or contaminated with water may rupture explosively.
In case of fire, keep containers cool with water spray. Keep unnecessary personnel away.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
If product is spilled in the solid state, pick up and place in an appropriate waste disposal container. If product is spilled in the molten state, allow product to solidify before scraping up and disposing of in an appropriate waste disposal container.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always be careful around molten material. Avoid skin contact with molten resins. See Section 8 of the SDS for Personal Protective Equipment. Precaution - this product should only be heated to recommended temperatures. Hazards of pyrolysis products emitted are unknown and may be hazardous to health. If recommended temperature is exceeded, there is an increased possibility that MDI may be released. Use caution if using container unloading equipment that inverts product, in order to avoid dislodging product prematurely. Do not place wet or damp solid into melt tank.
Do not let moisture contaminate this material. Product reacts with water to release carbon dioxide, which could build up pressure in closed containers and lead to bursting. Do not reseal if moisture contamination is suspected. Store in original container until ready to use.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination. Local exhaust should be used to maintain levels below the TLV whenever MDI is processed, heated or spray applied. Standard reference sources regarding industrial ventilation (i.e., ACGIH Industrial Ventilation) should be consulted for guidance about adequate ventilation. Air monitoring: Monitoring of airborne isocyanates in the breathing zone of individuals should become part of the overall employee exposure characterization program. Medical Surveillance: Medical supervision of all employees who handle or come in contact with isocyanates is recommended. Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates. Once a person is diagnosed as sensitized to an isocyanate, no further exposure can be permitted.
Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.
Concentrations greater than the TLV can occur when MDI is sprayed, heated or used in a poorly ventilated area. Use NIOSH approved respirator if there is potential to exceed exposure limit(s). A positive pressure, supplied-air respirator or a self-contained breathing apparatus is recommended when: airborne concentrations of isocyanate are known to exceed 0.005 ppm; operations are performed in a confined space or area with limited ventilation; material is heated or sprayed. Do not inhale vapors and fumes. Observe OSHA regulations for respirator use (29 CFR 1910.134).
Insulated gloves and long sleeved clothing are strongly recommended when working with molten adhesive.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
MDI reacts slowly with water to form carbon dioxide gas.
Exothermic. Polymerization may occur at elevated temperature or in the presence of incompatible materials.
Avoid moisture. Container can be pressurised by carbon dioxide due to reaction with humid air and/or water. Extremes of temperature and direct sunlight. Contamination with water.
Water. Alcohols. Amines. Moisture. Strong acids and strong bases.
Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Hydrogen cyanide. Isocyanate vapors
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PUR 3317 BR 12KG?
The signal word is danger.
What is the physical form of TECHNOMELT PUR 3317 BR 12KG?
TECHNOMELT PUR 3317 BR 12KG is a crystalline with amber to yellowish color. It has acrylic odor.
What is the solubility of TECHNOMELT PUR 3317 BR 12KG?
Insoluble Water
What is TECHNOMELT PUR 3317 BR 12KG used for?
Adhesive for the graphic industry
What are the hazard statements for TECHNOMELT PUR 3317 BR 12KG?
This substance has 5 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of TECHNOMELT PUR 3317 BR 12KG?
The melting point is -40 - -10 °C (-40°F - 14°F) and the boiling point is > 300 °C (> 572°F)Decomposes before boiling point is reached.