Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE CD 318R
- Product Form
- Adhesive
- Product Code
- 747587
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Toluene | 108-88-3 | 1 - 5% | Yes |
| Zinc oxide | 1314-13-2 | 1 - 5% | Yes |
| Potassium hydroxide | 1310-58-3 | 0.1 - 1% | Yes |
| Diethanolamine | 111-42-2 | 0.1 - 1% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. Get immediate medical attention.
Wash affected area immediately with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get immediate medical attention.
Get immediate medical attention. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide.
Not available.
During emergency conditions, overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately apparent. Obtain medical attention.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Confine in small area; use absorbent to clean up.
Prevent further leakage or spillage if safe to do so. Prevent contamination of soil and water.
Confine in small area; use absorbent to clean up.
Materials: absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear suitable protective clothing, safety glasses and gloves. Avoid skin and eye contact. Avoid breathing vapors or mists of this product. Keep container closed. Wash hands before breaks and immediately after handling the product.
Not available.
Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Will not occur.
Freezing conditions.
Acids and bases.
Oxides of carbon. Oxides of zinc.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE CD 318R?
The signal word is danger.
What is the physical form of AQUENCE CD 318R?
AQUENCE CD 318R is a liquid with red color. It has mild odor.
What is the solubility of AQUENCE CD 318R?
Dispersible
What are the hazard statements for AQUENCE CD 318R?
This substance has 3 hazard statements:
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.
- H373: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of AQUENCE CD 318R?
The melting point is > 100.0 °C (> 212°F) and the boiling point is > 100.0 °C (> 212°F).