Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)
- Product Code
- 771993
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Conversion coating
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS06
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Chromium trioxide | 1333-82-0 | 30 - 60% | Yes |
| Potassium tetrafluoroborate | 14075-53-7 | 10 - 30% | Yes |
| Tripotassium hexacyanoferrate | 13746-66-2 | 10 - 30% | Yes |
| Sodium fluoride | 7681-49-4 | 5 - 10% | Yes |
| Dipotassium hexafluorozirconate | 16923-95-8 | 5 - 10% | Yes |
Notes
IDH number: 771993 Product name: BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air. If breathing is difficult, give oxygen. Trained personnel should administer 2.5% calcium gluconate through a nebulizer for 20 minutes. Do not use mouth-to-mouth method if victim ingested or inhaled the substance.
Symptoms: Delayed effects possible after inhalation.
Remove contaminated clothing and footwear while rinsing the affected area with large amounts of running water for at least 15 minutes. GET IMMEDIATE MEDICAL ATTENTION. If iced solution of 0.13% aqueous Benzalkonium Chloride (Zephiran) or 2.5% calcium gluconate gel is available, rinsing may be limited to 5 minutes, with the soak solution or gel applied as soon as the rinsing is stopped. If using calcium gluconate gel, it should be continuously re-applied and massaged into the affected area until pain has been relieved for at least 30 minutes. If Benzalkonium Chloride (Zephiran) or calcium gluconate gel is not available, rinsing must continue until medical treatment is provided. Launder contaminated clothing before reuse. Discard any shoes or clothing items that cannot be decontaminated.
Symptoms: Chromate scabs and skin ulcers.
Immediately flush affected eye with large amounts of gently flowing water or 0.9% sterile saline solution for at least 15 minutes. Hold eyelid wide open. Get immediate medical attention. Eye flushing should continue during transportation to a doctor.
Get immediate medical attention. Do not induce vomiting. Attempt immediate administration of a fluoride binding substance: milk, chewable calcium carbonate tablets or 4-8 ounces (120-240 ml) of milk of magnesia or a liquid antacid. Avoid large amounts of liquid as it may induce vomiting. Provide a glass of water to dilute the material in the stomach. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
GET IMMEDIATE MEDICAL ATTENTION.
Medical Treatment
Treatment of hypocalcemia associated with corrosive fluoride compounds exposure may be corrected by intravenous calcium gluconate or calcium chloride. Treatment of hypomagnesemia may be corrected by intravenous magnesium sulfate. Topical 10% EDTA ointment can be used to treat chromate scabs and skin ulcers. A 10% ascorbic acid solution may speed healing if applied promptly.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.
Spills should be cleaned immediately to prevent dispersion of airborne dusts. Do not allow product to enter sewer or waterways.
Related Products
Similar products with comparable safety profiles
BONDERITE M-CR 1200S AERO known as ALODINE 1200S
---
BONDERITE M-CR 1201 AERO known as ALODINE 1201
---
BONDERITE M-CR 1132 AERO known as ALODINE 1132
---
BONDERITE M-CR 1500 AERO known as ALODINE 1500
---
BONDERITE M-CR 1201 CHROMATE COATING known as ALODINE 1201 MTO
---
BONDERITE M-NT 4595 CONV C known as ALODINE 4595
---
BONDERITE M-CR 1201 AERO CHROMATE COATING known as ALODINE 1201
---
BONDERITE M-CR T5900 RTU AERO known as ALODINE T 5900 RTU NR
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Avoid breathing dust. Wash thoroughly after handling. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material. Do not take internally. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Oxidizing agent, may cause spontaneous ignition of combustible materials. Keep away from heat, ignition sources and incompatible materials.
This product may react with strong reducing agents. This product may react with strong acids, bases and oxidizing agents. This material will react with glass, concrete, certain metals, silica containing materials, rubber, leather, and many organics.
Chromium oxide. Hydrogen fluoride.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1463
- Shipping Name
- Chromium trioxide, anhydrous mixture
- Transport Class
- 5.1 (6.1, 8)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)?
The signal word is danger.
What is the physical form of BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)?
BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY) is a solid with orange color. It has neutral odor.
What is the solubility of BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)?
Appreciable Water
What is BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY) used for?
Conversion coating
What are the hazard statements for BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)?
This substance has 10 hazard statements:
- H272: MAY INTENSIFY FIRE; OXIDIZER.
- H301: TOXIC IF SWALLOWED.
- H310 + H330: FATAL IN CONTACT WITH SKIN OR IF INHALED.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H340: MAY CAUSE GENETIC DEFECTS.
- H350: MAY CAUSE CANCER.
- H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of BONDERITE M-CR 1200S (MH LAB ONLY) known as ALODINE 1200S (MH LAB ONLY)?
The melting point is Not available. and the boiling point is Not applicable.