NextSDS Logo
Safety Data Sheet EN

Intershield 300HS Aluminium Part A

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Intershield 300HS Aluminium Part A
Product Code
ENA381

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional application of coatings and inks

Uses advised against

All Other Uses

Manufacturers & Suppliers

I

International Paint Ltd.

manufacturer

Stoneygate Lane, Felling, Gateshead, Tyne and Wear, NE10 0JY UK

+44 (0)191 469 6111

S

Supplier

+44 (0)191 469 6111

Emergency Contacts

National advisory body/Poison Centre

+44 (0)844 892 0111

Supplier

+44 (0)191 469 6111

24H

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H226 Flammable liquid and vapour.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P235 Keep cool.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P282 Wear eye or face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower.
P362 + P364 IF ON SKIN: Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
reaction product: bisphenol-A- (epichlorhydrin); epoxy resin EC: 500-033-5 25068-38-6 25 - 50% Yes
Cashew, nutshell liq., oligomeric reaction products with 1-chloro- 2,3-epoxypropane EC: 500-210-7 68413-24-1 10% Yes
aromatic hydrocarbons, C9 128601-23-0 8% Yes
xylene EC: 215-535-7 1330-20-7 5% Yes
Solvent naphtha (petroleum), light arom. EC: 265-199-0 64742-95-6 3% Yes
butan-1-ol EC: 200-751-6 71-36-3 1.5% Yes
[3-(2,3-epoxypropoxy) propyl]trimethoxysilane EC: 219-784-2 2530-83-8 1% Yes
1,3-bis[12-hydroxy-octadecamide-N-methylene]-benzene EC: 423-300-7 --- 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms: No known significant effects or critical hazards. No specific data.

Skin contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser. Do NOT use solvents or thinners.

Symptoms: Causes skin irritation. May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness.

Eye contact

Remove contact lenses, irrigate copiously with clean, fresh water, holding the eyelids apart for at least 10 minutes and seek immediate medical advice.

Symptoms: Causes serious eye irritation. Adverse symptoms may include the following: pain or irritation, watering, redness.

Ingestion

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Symptoms: Irritating to mouth, throat and stomach.

Immediate Medical Attention

In all cases of doubt, or when symptoms persist, seek medical attention. Seek immediate medical advice for eye contact and ingestion.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapour. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Runoff to sewer may create fire or explosion hazard. This material is toxic to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

For non-emergency personnel : No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Collect spillage.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapour or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Use chemical resistant gloves classified under Standard EN 374: Protective gloves against chemicals and micro-organisms. Recommended: Viton® or Nitrile gloves. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment. NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Respiratory

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
1.4
Colour Intensity
---
Physical State
Liquid.
Physical State Data
liquid
Kinematic Viscosity
Kinematic (room temperature): 249.77 mm²/s
Auto Ignition Temperature
Not available.
Vapor Pressure
Not available.
Appearance
---
Solubility In Water
---
Bulk Density
---
Crystallisation Point
---
Vapor Density
Not available.
Solidification Point
---
Flash Point
Closed cup: 42°C
Flammability
Not available.
Odor
Solvent.
Freezing Point
---
Decomposition Temperature
Not available.
State Under Standard Conditions
---
Metal Corrosion
---
Cloud Point
---
Voc Content
---
Softening Point
---
Upper Explosive Limit
Not available.
Density
---
Explosive Limits
---
Form
---
Solubility
Insoluble in the following materials: cold water.
Partition Coefficient
Not available.
Ph
Not applicable.
Dynamic Viscosity
---
Boiling Point
Not available.
Solubility In Fat
---
Lower Explosive Limit
Not available.
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Colour
Metallic.
Odor Threshold
Not available.
Molecular Weight
---
Properties Status
---
Melting Point
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

oxidizing materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Intershield 300HS Aluminium Part A?

The signal word is warning.

What is the physical form of Intershield 300HS Aluminium Part A?

Intershield 300HS Aluminium Part A is a liquid. with metallic. color. It has solvent. odor.

What is the solubility of Intershield 300HS Aluminium Part A?

Insoluble in the following materials: cold water.

What is Intershield 300HS Aluminium Part A used for?

Professional application of coatings and inks

What are the hazard statements for Intershield 300HS Aluminium Part A?

This substance has 5 hazard statements:

  • H226: Flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Intershield 300HS Aluminium Part A?

The melting point is Not available. and the boiling point is Not available..