01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Creatinine
Product Code
C4255
Chemical Name
Creatinine

Regulatory Identifiers

CAS Number
60-27-5 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich

manufacturer

M

Merck Life Science BV

distributor

Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
2-Imino-1-methylimidazolidin-4-one2-Imino-N-methylhydantoin2-Amino-1-methyl-2-imidazolin-4-one EC: 200-466-7 60-27-5 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most).

Immediate Medical Attention

Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water Foam Carbon dioxide (CO2) Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides, Nitrogen oxides (NOx). Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
---
Ph
7,0 - 9,0 at 50 g/l at 20 °C
Odor Threshold
---
Evaporation Rate
---
State Under Standard Conditions
---
Flammability
---
Physical State Data
solid
Molecular Weight
---
Colour Intensity
---
Auto Ignition Temperature
>360 °C
Solidification Point
---
Explosive Limits
---
Decomposition Temperature
305 °C
Upper Explosive Limit
---
Solubility
---
Freezing Point
---
Softening Point
---
Density
1,39 g/cm3 at 20,3 °C - OECD Test Guideline 109
Odor
odourless
Relative Evaporation Rate
---
Voc Content
---
Metal Corrosion
---
Lower Explosive Limit
---
Boiling Point
---
Cloud Point
---
Bulk Density
---
Flash Point
290 °C - closed cup - c.c.
Solubility In Fat
---
Partition Coefficient
log Pow: -1,76 - (Lit.), Bioaccumulation is not expected.
Form
---
Dynamic Viscosity
---
Crystallisation Point
---
Relative Density
1,39 at 20,3 °C - OECD Test Guideline 109
Physical State
powder
Properties Status
---
Melting Point
Melting point/ range: 295 °C
Solubility In Water
90 g/l at 20 °C
Vapor Pressure
---
Colour
white
Appearance
---
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical. The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Caution! In contact with nitrites, nitrates, nitrous acid possible liberation of nitrosamines! Violent reactions possible with: Strong oxidizing agents

Avoid

Strong heating.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Creatinine?

The signal word is no signal word.

What is the physical form of Creatinine?

Creatinine is a powder with white color. It has odourless odor.

What is Creatinine used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Creatinine?

The melting point is Melting point/ range: 295 °C .