NextSDS Logo
Safety Data Sheet EN

Rat IFN-gamma DuoSet

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Rat IFN-gamma DuoSet
Product Code
DY585

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For Research Use Only

Manufacturers & Suppliers

R

R&D Systems Inc.

manufacturer

614 McKinley Place N.E., Minneapolis, MN 55413 USA

1-800-343-7475

Emergency Contacts

R&D Systems

(612) 379-2956

R&D Systems

(800)-343-7475

R&D Systems

+44(0)1235-529449

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P261 Avoid breathing mist.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P333 + P313 If skin irritation or rash occurs: get medical attention.
P363 Wash contaminated clothing before reuse.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Modified Alkyl Carboxylate --- 0.01% No
Mixture of 5-Cloro-2-Methyl-4-Isothiazolin-3-One (26172-55-4) and -Methyl-4-Isothiazolin-3-One (2682-20-4) 55965-84-9 0.01% No
Modified Glycol --- 1.6% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin contact

Immediately take off contaminated clothing or shoes. Wash with plenty of soap and water. Consult a physician.

Eye contact

Rinse thoroughly with water for at least 15 minutes and immediately consult a physician.

Ingestion

Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Immediately consult a physician.

Immediate Medical Attention

Immediately consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Firefighter Protection

Self contained breathing apparatus and full protective clothing must we worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas.

Environmental

Keep away from drains.

Cleanup methods

Soak up with inert absorbent material and dispose of as hazardous waste.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.

Storage

Store in a cool, dry place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Fire prevention

Use normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with protective gloves, plastic or rubber. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

Eyes

Wear approved safety goggles.

Respiratory

In case of inadequate ventilation, use a suitable respirator. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Wear suitable protective clothing as protection against splashing or contamination. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear Liquid
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
-40° C
Boiling Point
189° C
Flash Point
118° C - closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
1.03 g/cm³
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Incompatible

Strong oxidizing agents, reducing agents, Amines, Mercaptans

Decomposition

Hazardous decomposition products formed under fire conditions – Carbon oxides, nitrogen oxides (NOx), Sulphur oxides, Hydrogen chloride gas.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Rat IFN-gamma DuoSet?

The signal word is warning.

What is the physical form of Rat IFN-gamma DuoSet?

Rat IFN-gamma DuoSet is a liquid appearing as clear liquid .

What is Rat IFN-gamma DuoSet used for?

For Research Use Only

What are the hazard statements for Rat IFN-gamma DuoSet?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of Rat IFN-gamma DuoSet?

The melting point is -40° C and the boiling point is 189° C.