Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Extrol Neutral Cleaner
- Synonyms
- AP150
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
All-purpose cleaner
Manufacturers & Suppliers
Bio Productions Ltd
manufacturer
72 Victoria Road, Burgess Hill, RH15 9LH, United Kingdom
0044 (0) 1444 244000
Emergency Contacts
Emergency Contact
0044 (0) 1444 244000
office hours only
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propan-2-ol EC: 200-661-7 | 67-63-0 | 5% | Yes |
| Ethoxylated C9-C11 alcohols | 68439-45-2 | 5% | Yes |
| Perfume | --- | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If affected, remove to fresh air, keep warm and at rest. Obtain medical attention in severe cases.
Symptoms: Mist may cause irritation to the respiratory tract
Immediately remove all contaminated clothing. Wash skin with soap and water. In severe cases obtain medical help.
Symptoms: May cause irritation/allergic reaction
In case of contact, rinse immediately with plenty of water for at least 10-15 minutes. Obtain medical attention if irritation persists
Symptoms: May cause mild irritation
Do not give anything by mouth to an unconscious person. Wash out mouth with water and give copious amounts of water to drink. Do not induce vomiting. Obtain medical advice if patient unwell.
Symptoms: May cause irritation to the mouth, throat and digestive tract
Immediate Medical Attention
Obtain medical attention in severe cases (inhalation, skin contact), if irritation persists (eye contact), or if patient is unwell (ingestion).
Medical Treatment
Symptomatic treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, foam, sand, dry powder, or CO2
In combustion emits toxic fumes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark out the contaminated area with signs and prevent access to unauthorised personnel. Do not attempt to take action without suitable protective clothing – see section 8 of SDS
Small spills can be handled with a mop and water.
Large spills should be contained with sawdust and disposed of under local authority regulations
Do not discharge into drains or rivers. Contain the spillage using bunding.
mop and water
Related Products
Similar products with comparable safety profiles
Eclipse Neutral All Purpose Cleaner
---
EnviroStar Green All Purpose Neutralizer
---
EnviroStar Green All Purpose Neutralizer
---
FRAGOLTHERM® Cleaning Fluid 350
CAS: 61788-32-7
BONDERITE C-NE 225 NEUTRAL CLEANER known as P3 NEUTRACARE 225
---
BONDERITE C-NE 200 NEUTRAL CLEANER known as P3 NEUTRACARE 200
---
BONDERITE C-NE 5156 NEUTRAL CLEANER known as P3 NEUTRACARE 5156
---
Interflon Clean Special
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid eye contact and prolonged skin contact
Keep in original containers
Store away from sparks, naked flames or sources of ignition
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear protective gloves (Butyl rubber or Polyvinyl chloride)
Wear safety goggles
Not necessary under normal usage
Wear suitable protective overalls
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
Extremes of temperature
Strong oxidising/reducing agents
Burning produces Oxides of Carbon
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Extrol Neutral Cleaner known by?
Extrol Neutral Cleaner is also known as: AP150
What is the hazard signal word for Extrol Neutral Cleaner?
The signal word is no signal word.
What is the physical form of Extrol Neutral Cleaner?
Extrol Neutral Cleaner is a liquid with green color. It has floral odor.
What is Extrol Neutral Cleaner used for?
All-purpose cleaner
What is the melting point of Extrol Neutral Cleaner?
The melting point is <0 degrees celcius and the boiling point is >100 degrees celcius.