Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- INTO FORTE
- Product Code
- 108539E
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Sanitary cleaner
Uses advised against
Reserved for industrial and professional use.
Manufacturers & Suppliers
Ecolab Ltd.
manufacturer
PO Box 11; Winnington Avenue, Northwich, Cheshire, United Kingdom CW8 4DX
+ 44 (0)1606 74488
Emergency Contacts
Emergency Contact
+441618841235
Trans-European
+32-(0)3-575-5555
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty alcohol ethoxylates > 5EO EC: 500-236-9 | 68920-66-1 | 2.5 - 5% | Yes |
| Phosphoric acid EC: 231-633-2 | 7664-38-2 | 30 - 50% | Yes |
| Alkylarylsulphonic acid EC: 287-494-3 | 85536-14-7 | 1 - 2.5% | Yes |
| iron(ii) sulfate heptahydrate EC: 231-753-5 | 7782-63-0 | 1 - 2.5% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 0.5 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Treat symptomatically. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. Use a mild soap if available. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.
Rinse mouth with water. Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention immediately.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
None known.
Not flammable or combustible.
In the event of fire and/or explosion do not breathe fumes.
Firefighter Protection
Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Ensure clean-up is conducted by trained personnel only.
dike spilled material or otherwise contain material to ensure runoff does not reach a waterway
Do not allow contact with soil, surface or ground water.
collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not ingest. Do not get in eyes, on skin, or on clothing. Do not breathe dust/fume/gas/mist/vapours/spray. Use only with adequate ventilation. Wash hands thoroughly after handling. Do not mix with bleach or other chlorinated products – will cause chlorine gas.
Keep container tightly closed. Store in suitable labeled containers. Keep only in original container.
Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Effective exhaust ventilation system. Maintain air concentrations below occupational exposure standards.
Recommended preventive skin protection Gloves Nitrile rubber butyl-rubber Breakthrough time: 1 – 4 hours Minimum thickness for butyl-rubber 0.7 mm for nitrile rubber 0.4 mm or equivalent (please refer to the gloves manufacturer/distributor for advise). Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.
Safety goggles Face-shield
None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, 89/686/EEC ), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.
Personal protective equipment comprising: suitable protective gloves, safety goggles and protective clothing
Consider the provision of containment around storage vessels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Do not mix with bleach or other chlorinated products – will cause chlorine gas.
None known.
bleach or other chlorinated products
chlorine gas
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1805
- Shipping Name
- PHOSPHORIC ACID SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for INTO FORTE?
The signal word is danger.
What is the physical form of INTO FORTE?
INTO FORTE is a liquid appearing as liquid with red color. It has perfumes, fragrances odor.
What is INTO FORTE used for?
Sanitary cleaner
What are the hazard statements for INTO FORTE?
This substance has 2 hazard statements:
- H290: May be corrosive to metals.
- H314: Causes severe skin burns and eye damage.
What is the melting point of INTO FORTE?