Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Luchtverfrisser
Product Form
Mixture
Product Code
280415

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaners, liquids (all purpose cleaners, sanitary products, floor cleaners, glass cleaners, carpet cleaners, metal cleaners, air fresheners)

Uses advised against

No additional information available

Manufacturers & Suppliers

Boma B.V. logo

Boma B.V.

distributor

Molenbaan 4, 2908 LM Capelle aan den IJssel - Nederland

+31(0)77 306 18 78

http://www.boma.eu

Emergency Contacts

National Poisons Information Service (Birmingham Centre) City Hospital

0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P102 Keep out of reach of children.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ethanol EC: 200-578-6 64-17-5 15 - 25% Yes
Isopropyl alcohol EC: 200-661-7 67-63-0 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get medical advice/attention if you feel unwell.

Skin contact

If skin irritation or rash occurs: Get medical advice/attention.

Eye contact

If eye irritation persists: Get medical advice/attention.

Ingestion

Get medical advice/attention if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Foam. Carbon dioxide. Dry powder.

Specific hazards

No fire hazard.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Clean up any spills as soon as possible, using an absorbent material to collect it.

Environmental

Do not allow to enter drains or water courses.

Cleanup methods

Clean up any spills as soon as possible, using an absorbent material to collect it.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not eat, drink or smoke when using this product.

Storage

Store away from heat. Keep storage area clean. Ensure that there is a suitable ventilation system.

Hygiene

Do not eat, drink or smoke when using this product.

Fire prevention

Store away from heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

Protective gloves. Type: Disposable gloves, Material: Nitrile rubber (NBR), Permeation: 2 (> 30 minutes), Penetration: 2 (< 1.5), Standard: EN ISO 374

Eyes

Type: Safety glasses, Use: Droplet, Characteristics: With side shields, Standard: EN 166

Environmental

Carefully comply with the instructions for use. Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
white.
Colour Intensity
---
Form
---
Odor
perfumed.
Odor Threshold
No data available
Ph
6
Melting Point
No data available
Boiling Point
No data available
Flash Point
36 °C
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
---
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
0,99 g/cm³
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
completely soluble.
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
< 20 mPa·s
Kinematic Viscosity
< 20,202 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of use.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

Stable under normal conditions of use

Avoid

No additional information available

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Luchtverfrisser?

The signal word is no signal word.

What is the physical form of Luchtverfrisser?

Luchtverfrisser is a liquid with white. color. It has perfumed. odor.

What is the solubility of Luchtverfrisser?

completely soluble.

What is Luchtverfrisser used for?

Cleaners, liquids (all purpose cleaners, sanitary products, floor cleaners, glass cleaners, carpet cleaners, metal cleaners, air fresheners)

What is the melting point of Luchtverfrisser?

The melting point is No data available and the boiling point is No data available.