NextSDS Logo
Safety Data Sheet EN

Super C2 Sanitairreiniger

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Super C2 Sanitairreiniger

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial cleaner.

Manufacturers & Suppliers

Quaron Cleaning Systems B.V. logo

Quaron Cleaning Systems B.V.

manufacturer

Groot Mijdrechtstraat 52, 3641 RW Mijdrecht Nederland

+31-297-274390

http://www.quaron-cs.com

Emergency Contacts

Quaron Cleaning Systems B.V.

+31-(0)297-274390

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Regulation (CE) No. 648/2004 of 31 March 2004 on detergents: Contains : < 5% : - Anionic surfactants 5% - 15% : - Nonionic surfactants Perfumes Butylphenyl Methylpropional, Linalool, Citronellol, Hexyl Cinnamal, Limonene (D-).

Chemical Name CAS Number Concentration Hazardous
Sodium laurylethersulfate (2,2 E.O.) 68891-38-3 1 - 5% Yes
L-(+)-lactic acid EC: 201-196-2 79-33-4 15 - 30% Yes
Citric acid monohydrate EC: 201-069-1 5949-29-1 5 - 15% Yes
Fatty alcohol EO/PO 68154-97-2 5 - 15% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air.

Skin contact

Rinse immediately with plenty of water.

Eye contact

Flush eyes as soon as possible with running water for 15 minutes, while keeping the eyelids wide open.

Ingestion

Rinse mouth. Give water to drink.

Immediate Medical Attention

Seek medical attention if ill effect or irritation develops (for skin and eye contact). Seek medical attention immediately (for ingestion).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Not combustible. All extinguishing media can be used.

Firefighter Protection

No special requirements.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Prevent entry to sewers, ground and public waters.

Cleanup methods

Clean up any spills as soon as possible, using an absorbent material to collect the spill. Dilute residues and flush.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well-ventilated areas.

Storage

Store in dry, cool, well-ventilated area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Use rubber gloves.

Eyes

Safety glasses.

Respiratory

Not required.

Skin/Body

If skin contact or contamination of clothing is likely, protective clothing should be worn.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
---
Appearance
---
Relative Evaporation Rate
---
Solubility
---
Melting Point
---
Vapor Pressure
---
Auto Ignition Temperature
Not applicable.
Odor
Pleasant.
Solubility In Fat
---
Colour
Red.
Decomposition Temperature
---
Boiling Point
100 °C
Cloud Point
---
Evaporation Rate
---
Colour Intensity
---
Flammability
---
Physical State Data
liquid
Form
---
Ph
2.3
Lower Explosive Limit
Not applicable.
Vapor Density
---
Solidification Point
---
Relative Density
---
Explosive Limits
---
Freezing Point
---
Molecular Weight
---
Kinematic Viscosity
---
Dynamic Viscosity
<10 mPa.s
Density
1.06 g/cm3
Upper Explosive Limit
---
Softening Point
---
Odor Threshold
---
Properties Status
---
Crystallisation Point
---
Bulk Density
---
Metal Corrosion
---
Solubility In Water
Mixable in all proportions
Flash Point
---
Physical State
Liquid.
Voc Content
---
State Under Standard Conditions
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Hazardous reactions

Reacts violently with : Strong alkalis.

Incompatible

Strong alkalis. Bleach

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Super C2 Sanitairreiniger?

The signal word is na: r-phrases.

What is the physical form of Super C2 Sanitairreiniger?

Super C2 Sanitairreiniger is a liquid. with red. color. It has pleasant. odor.

What is Super C2 Sanitairreiniger used for?

Industrial cleaner.