Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Desoximetasone Related Compound A
- Product Code
- 1173519
- Synonyms
- 1,2-Dihydro desoxymetasone
Regulatory Identifiers
- CAS Number
- 432-54-2 Check regulations →
Identified Uses
Specified quality tests and assay use only.
Uses advised against
Not for use as a drug. Not for administration to humans or animals.
Manufacturers & Suppliers
U. S. Pharmacopeia
manufacturer
12601 Twinbrook Parkway Rockville MD 20852-1790 United States
301-816-8129
www.usp.org
Emergency Contacts
CHEMTREC within US & Canada
1-800-424-9300
CHEMTREC outside US & Canada
+1 703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Desoximetasone Related Compound A | 432-54-2 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Rinse skin with water/shower. Get medical attention if irritation develops and persists.
Rinse with water. Get medical attention if irritation develops and persists.
Rinse mouth. If ingestion of a large amount does occur, call a poison control center immediately.
Immediate Medical Attention
Persons developing serious hypersensitivity (anaphylactic) reactions must receive immediate medical attention.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water. Foam. Dry chemical or CO2. Use fire-extinguishing media appropriate for surrounding materials.
None known.
No unusual fire or explosion hazards noted.
Use water spray to cool unopened containers. As with all fires, evacuate personnel to a safe area. Use standard firefighting procedures and consider the hazards of other involved materials.
Firefighter Protection
Wear suitable protective equipment. Firefighters should use self-contained breathing equipment and protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unnecessary personnel away. Wear appropriate personal protective equipment. Avoid inhalation of dust from the spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ensure adequate ventilation.
Avoid discharge into drains, water courses or onto the ground.
Sweep up or vacuum up spillage and collect in suitable container for disposal. Clean surface thoroughly to remove residual contamination.
Materials: suitable container
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
As a general rule, when handling USP Reference Standards, avoid all contact and inhalation of dust, mists, and/or vapors associated with the material. Clean equipment and work surfaces with suitable detergent or solvent after use. After removing gloves, wash hands and other exposed skin thoroughly. Select and use containment devices and personal protective equipment based on a risk assessment of material potency and exposure potential.
Store in tight container as defined in the USP-NF. This material should be handled and stored per label instructions to ensure product integrity.
After removing gloves, wash hands and other exposed skin thoroughly.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Control exposures to below the occupational exposure level (if available). Select and use containment devices and personal protective equipment based on a risk assessment of exposure potential. Cover all containers for solutions and slurries while being transferred. For laboratory operations, use approved ventilation or containment system (biological safety cabinet, ventilated balance enclosure, glovebox). No open handling.
Wear nitrile or other impervious gloves if skin contact is possible. When the material is dissolved or suspended in an organic solvent, wear gloves that provide protection against the solvent. Consider double gloves.
Wear safety glasses with side shields, chemical splash goggles, or full face shield, if necessary. Base the choice of protection on the job activity and potential for contact with eyes or face. An emergency eye wash station should be available.
Chose respiratory protection appropriate to the task and the level of existing engineering controls. Use a powered air-purifying respirator (PAPR) with HEPA filters, disposable outerware and head cover for spill cleanup.
Base the choice of skin protection on the job activity, potential for skin contact and solvents and reagents in use. Do not wear protective garments in common areas (e.g., cafeterias) or out-of-doors. Train employees in proper gowning and degowning practices. Wear disposable lab coat, disposable sleeve covers and two pair of gloves as appropriate for the task.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Contact with incompatible materials.
Strong oxidizing agents.
Irritating and/or toxic fumes or gases. Emits toxic fumes under fire conditions. F-.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Desoximetasone Related Compound A known by?
Desoximetasone Related Compound A is also known as: 1,2-Dihydro desoxymetasone
What is the hazard signal word for Desoximetasone Related Compound A?
The signal word is warning.
What is the physical form of Desoximetasone Related Compound A?
Desoximetasone Related Compound A is a solid. with off-white. beige. color. It has not available. odor.
What is Desoximetasone Related Compound A used for?
Specified quality tests and assay use only.
What are the hazard statements for Desoximetasone Related Compound A?
This substance has 2 hazard statements:
- H361: Suspected of damaging fertility or the unborn child.
- H372: May cause damage to organs (endocrine system) through prolonged or repeated exposure.
What is the melting point of Desoximetasone Related Compound A?
The melting point is 359.6 - 363.2 °F (182 - 184 °C) and the boiling point is Not available..