Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Roto-Inject Fluid Ndurance
- Product Code
- 0017 5300 10
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Compressor Oil.
Manufacturers & Suppliers
Atlas Copco Airpower nv
manufacturer
Boomsesteenweg 957, 2610 Wilrijk, Belgium
+32 3 870 2111
Atlas Copco UK
distributor
+44 845 601 0001
Emergency Contacts
medical service of Atlas Copco Airpower
+32 3 870 2105
8am-5pm CET
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Highly refined mineral oils and additives The highly refined mineral oil contains <3% (w/w) DMSO extract, according to IP346.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Interchangeable low viscosity base oil (<20,5 cSt @40°C) * | --- | 90% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.
Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.
Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas.
Flush eye with copious quantities of water. If persistent irritation occurs, obtain medical attention.
In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.
Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.
Do not use water in a jet.
Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide may be evolved if incomplete combustion occurs. Unidentified organic and inorganic compounds.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Firefighter Protection
Proper protective equipment including breathing apparatus must be worn when approaching a fire in a confined space.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin and eyes.
Use appropriate containment to avoid environmental contamination.
Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.
Materials: absorbent such as clay, sand or other suitable material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid prolonged or repeated contact with skin. Avoid inhaling vapour and/or mists. When handling product in drums, safety footwear should be worn and proper handling equipment should be used. Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.
Keep container tightly closed and in a cool, well-ventilated place. Store at ambient temperature.
Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Define procedures for safe handling and maintenance of controls. Educate and train workers in the hazards and control measures relevant to normal activities associated with this product. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or for subsequent recycle.
Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with reference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same, but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.
If material is handled such that it could be splashed into eyes, protective eyewear is recommended. Approved to EU Standard EN166.
No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [Type A/Type P boiling point > 65°C (149°F)] meeting EN14387 and EN143.
Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.
Take appropriate measures to fulfil the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Chapter 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable. No hazardous reaction is expected when handled and stored according to provisions
The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.
Reacts with strong oxidising agents.
Extremes of temperature and direct sunlight.
Strong oxidising agents.
Hazardous decomposition products are not expected to form during normal storage.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Roto-Inject Fluid Ndurance?
The signal word is no signal word.
What is the physical form of Roto-Inject Fluid Ndurance?
Roto-Inject Fluid Ndurance is a liquid appearing as liquid at room temperature. with light brown color. It has slight hydrocarbon odor.
What is Roto-Inject Fluid Ndurance used for?
Compressor Oil.