NextSDS Logo
Safety Data Sheet EN

Roto-Inject Fluid Ndurance

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Roto-Inject Fluid Ndurance
Product Code
0017 5300 10

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Compressor Oil.

Manufacturers & Suppliers

A

Atlas Copco Airpower nv

manufacturer

Boomsesteenweg 957, 2610 Wilrijk, Belgium

+32 3 870 2111

A

Atlas Copco UK

distributor

+44 845 601 0001

Emergency Contacts

medical service of Atlas Copco Airpower

+32 3 870 2105

8am-5pm CET

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Highly refined mineral oils and additives The highly refined mineral oil contains <3% (w/w) DMSO extract, according to IP346.

Chemical Name CAS Number Concentration Hazardous
Interchangeable low viscosity base oil (<20,5 cSt @40°C) * --- 90% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.

Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas.

Eye contact

Flush eye with copious quantities of water. If persistent irritation occurs, obtain medical attention.

Ingestion

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.

Unsuitable media

Do not use water in a jet.

Specific hazards

Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide may be evolved if incomplete combustion occurs. Unidentified organic and inorganic compounds.

Instructions

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Proper protective equipment including breathing apparatus must be worn when approaching a fire in a confined space.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes.

Environmental

Use appropriate containment to avoid environmental contamination.

Cleanup methods

Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.

Materials: absorbent such as clay, sand or other suitable material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid prolonged or repeated contact with skin. Avoid inhaling vapour and/or mists. When handling product in drums, safety footwear should be worn and proper handling equipment should be used. Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.

Storage

Keep container tightly closed and in a cool, well-ventilated place. Store at ambient temperature.

Fire prevention

Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Define procedures for safe handling and maintenance of controls. Educate and train workers in the hazards and control measures relevant to normal activities associated with this product. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or for subsequent recycle.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with reference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same, but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended. Approved to EU Standard EN166.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [Type A/Type P boiling point > 65°C (149°F)] meeting EN14387 and EN143.

Skin/Body

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

Environmental

Take appropriate measures to fulfil the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Chapter 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Pow: > 6(based on information on similar products)
Freezing Point
---
Odor
Slight hydrocarbon
Physical State Data
liquid
Physical State
Liquid
Solubility In Fat
---
State Under Standard Conditions
---
Lower Explosive Limit
Typical 1 %(V)
Bulk Density
---
Colour Intensity
---
Density
870 kg/m3 (15,0 °C)
Solubility In Water
negligible
Crystallisation Point
---
Vapor Density
---
Metal Corrosion
---
Solubility
---
Boiling Point
> 280 °C estimated value(s)
Vapor Pressure
< 0,5 Pa (20 °C) estimated value(s)
Kinematic Viscosity
55 mm2/s (40,0 °C) Method: Unspecified
Molecular Weight
---
Form
---
Upper Explosive Limit
Typical 10 %(V)
Softening Point
---
Evaporation Rate
Data not available
Colour
light brown
Explosive Limits
---
Odor Threshold
Data not available
Ph
Not applicable.
Flash Point
250 °C Method: ASTM D92
Solidification Point
---
Dynamic Viscosity
Data not available
Appearance
Liquid at room temperature.
Decomposition Temperature
---
Relative Evaporation Rate
---
Relative Density
0,870 (15 °C)
Melting Point
---
Properties Status
---
Flammability
Data not available
Auto Ignition Temperature
> 320 °C
Cloud Point
---
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable. No hazardous reaction is expected when handled and stored according to provisions

Reactivity

The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.

Hazardous reactions

Reacts with strong oxidising agents.

Avoid

Extremes of temperature and direct sunlight.

Incompatible

Strong oxidising agents.

Decomposition

Hazardous decomposition products are not expected to form during normal storage.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Roto-Inject Fluid Ndurance?

The signal word is no signal word.

What is the physical form of Roto-Inject Fluid Ndurance?

Roto-Inject Fluid Ndurance is a liquid appearing as liquid at room temperature. with light brown color. It has slight hydrocarbon odor.

What is Roto-Inject Fluid Ndurance used for?

Compressor Oil.