Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acetone
- Product Code
- 268310000; 268310010; 268310025
- Chemical Name
- Acetone
- Synonyms
- 2-Propanone
Regulatory Identifiers
- CAS Number
- 67-64-1 Check regulations →
- EC Number
- 200-662-2 Check regulations →
- REACH No.
- 01-2119471330-49
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetone EC: 200-662-2 | 67-64-1 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Symptoms: Difficulty in breathing.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam. Water mist may be used to cool closed containers.
Do not use water jetstream.
Flammable. Risk of ignition. Containers may explode when heated. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid ingestion and inhalation. Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Take precautionary measures against static discharges.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. All metal parts of the equipment must be grounded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Use explosion-proof electrical/ventilating/lighting equipment. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Butyl rubber: > 480 minutes, 0.5 mm, EN 374 Level 6 (As tested under EN374-3 Determination of Resistance to Permeation by Chemicals). Neoprene gloves: < 30 minutes, 0.45 mm.
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: low boiling organic solvent Type AX Brown conforming to EN371. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141. When RPE is used a face piece Fit Test should be conducted.
Long sleeved clothing.
Do not allow material to contaminate ground water system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous polymerization does not occur.
Heat, flames and sparks. Incompatible products. Keep away from open flames, hot surfaces and sources of ignition.
Strong oxidizing agents. Strong reducing agents. Strong bases. Peroxides. Halogenated compounds. Alkali metals. Amines.
Carbon monoxide (CO). Carbon dioxide (CO₂). Formaldehyde. Methanol.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1090
- Shipping Name
- ACETONE
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Acetone known by?
Acetone is also known as: 2-Propanone
What is the hazard signal word for Acetone?
The signal word is danger.
What is the physical form of Acetone?
Acetone is a liquid appearing as colorless . It has sweet odor.
What is Acetone used for?
Laboratory chemicals.
What are the hazard statements for Acetone?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapor
- H319: Causes serious eye irritation
- H336: May cause drowsiness or dizziness
What is the melting point of Acetone?
The melting point is -95 °C / -139 °F and the boiling point is 56 °C / 132.8 °F.