NextSDS Logo
Safety Data Sheet EN

FLOOR & MAXI CLEANER

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FLOOR & MAXI CLEANER
Product Code
H100061 – H100062

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Floor cleaner - Cleaning material/ Detergent - All-purpose cleaner

Manufacturers & Suppliers

MULTITASK INDUSTRIES logo

MULTITASK INDUSTRIES

manufacturer

KARNEMELKSTRAAT 12 9060 ZELZATE / BELGIUM

+32 (0)9 282 43 61

http://www.multitaskindustries.be

Emergency Contacts

Poison control centre (Brussels)

+32 (0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash thoroughly after handling.
P280 Wear eye protection / face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Isotridecanol, ethoxylated (>5-20 EO) EC: 931-138-8 69011-36-5 2.5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

The product is not skin irritating.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

Ingestion

In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire fighting measures that suit the environment. Water.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow to enter drainage system, surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions necessary if used correctly.

Storage

Keep container tightly sealed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: > 0,5 mm / 240 min. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed safety glasses.

Respiratory

Not required.

Skin/Body

Wear protective clothing when using the pure liquid or if there is prolonged exposure to the liquid itself. For example in the case of refilling or leakage.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Yellowish.
Colour Intensity
---
Form
Fluid.
Odor
Pleasant.
Odor Threshold
Not determined.
Ph
10
Melting Point
Not determined.
Boiling Point
100°C
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
~ 1.07 g/cm³.
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
The product is not self igniting.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FLOOR & MAXI CLEANER?

The signal word is warning.

What is the physical form of FLOOR & MAXI CLEANER?

FLOOR & MAXI CLEANER is a fluid. with yellowish. color. It has pleasant. odor.

What is FLOOR & MAXI CLEANER used for?

Floor cleaner - Cleaning material/ Detergent - All-purpose cleaner

What are the hazard statements for FLOOR & MAXI CLEANER?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of FLOOR & MAXI CLEANER?

The melting point is Not determined. and the boiling point is 100°C.