Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lithium Ion Battery (Module)
- Synonyms
- Industrial Battery
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For use as a rechargeable battery (module)
Manufacturers & Suppliers
Hawker Powersource
manufacturer
9404 Ooltewah Industrial Drive, Ooltewah, TN 37363
423-238-5700
Emergency Contacts
HAWKER Environmental, Health & Safety Dept.
423-238-5700
CHEMTREC DOMESTIC
800-424-9300
CHEMTREC INT'L
703-527-3877
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Graphite | 7782-42-5 | 7 - 25% | No |
| Cobalt lithium manganese nickel oxide | 182442-95-1 | 5 - 40% | No |
| 1-Propene,1,1,2,3,3,3-hexafluoro-, polymer with 1,1-difluoroethene | 9011-17-0 | 3 - 15% | No |
| Lithium hexafluorophosphate | 21324-40-3 | 5% | No |
| Carbon black | 1333-86-4 | 2% | No |
| Diethyl carbonate | 105-58-8 | 15% | No |
| Dimethyl carbonate | 616-38-6 | 15% | No |
| Ethyl methyl carbonate | 623-53-0 | 15% | No |
| Propylene carbonate | 108-32-7 | 15% | No |
| Ethylene carbonate | 96-49-1 | 15% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air and seek medical attention. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Remove contaminated clothing and wash skin with soap and water. If a chemical burn occurs or if irritation persists, seek medical attention.
Symptoms: chemical burn
Flush immediately with large amounts of water for at least 15 minutes while lifting lids until no evidence of the chemical remains. Seek medical attention.
Symptoms: chemical burns
Seek medical attention immediately. Do not induce vomiting or give food or drink.
Immediate Medical Attention
Seek immediate attention if internal components come into contact with skin, eyes, or are ingested.
Medical Treatment
If ingested, treatment to prevent fluorosis may be required.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
excess of water spray, dry chemical, CO2 or foam.
Burning battery (module) and batteries may produce highly toxic carbon monoxide, suffocating carbon dioxide and toxic corrosive hydrogen fluoride gas. Fumes may cause dizziness or suffocation.
The cooling effect of water effectively impedes fire from spreading to battery cells which still have not reached the critical ignition temperature (thermal runaway)
Firefighter Protection
Wear self-contained breathing apparatus, protective clothing, gloves, face and eye protection
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective clothing, boots, gloves, and face shield. Ensure adequate ventilation.
Place material into suitable containers
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear protective clothing, eye and face protection when charging or handling of batteries (module). Do not touch eyes, nose, or mouth. Do not allow metallic materials to simultaneously contact positive and negative terminals of battery (module). Packaged batteries (modules) must be separated in a way to prevent short circuits or damage to terminals. Keep battery (module) away from incompatible materials (see Section 10). Use banding or stretch wrap to secure items for shipping.
Store battery (module) in cool, dry areas away from heat and incompatible materials (see Section 10). Cover the terminals with protective case when not in use. Avoid damage to containers. Keep away from fire, sparks and heat. Avoid excessive physical shock or vibration. Battery (module) should be stored at between 25% and 75% of full charge during long-term storage.
Do not touch eyes, nose, or mouth.
Keep away from fire, sparks and heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This product is stable under normal conditions at standard temperature.
Not considered reactive under normal conditions at ambient temperature.
Violent reaction may occur in contact with hot, concentrated acid, strong oxidizers, and water. Hazardous polymerization: Will not occur.
Avoid heat, sources of ignition, and contact with strong acids, strong oxidizers, and corrosive material.
Combustible materials, organic chemicals, strong acids (such as nitric, hydrochloric, or sulfuric acids), reducing substances, strong oxidizers (such as perchlorates, peroxides, permanganates, chlorates, and nitrates), and chemically active metals (such as potassium, sodium, magnesium, and zinc). If aluminum foil packaging is damaged, avoid contact with water or acid because these may damage the battery (module) or cause a short circuit. If the aluminum foil packaging is damaged, strong oxidizers, acids and high temperatures may cause hydrogen fluoride gas to be formed.
Not available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3480
- Shipping Name
- Lithium ion batteries
- Transport Class
- 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Lithium Ion Battery (Module) known by?
Lithium Ion Battery (Module) is also known as: Industrial Battery
What is the hazard signal word for Lithium Ion Battery (Module)?
The signal word is danger.
What is the physical form of Lithium Ion Battery (Module)?
Lithium Ion Battery (Module) is a solid appearing as battery (module) product. . It has none. odor.
What is the solubility of Lithium Ion Battery (Module)?
Not applicable.
What is Lithium Ion Battery (Module) used for?
For use as a rechargeable battery (module)
What are the hazard statements for Lithium Ion Battery (Module)?
This substance has 4 hazard statements:
- H225: Highly flammable liquid and vapor.
- H314: Causes severe skin burns and eye damage.
- H372: Causes damage to organs (teeth, bones) through prolonged or repeated exposure
- H400: Toxic to aquatic life.
What is the melting point of Lithium Ion Battery (Module)?
The melting point is Not applicable. and the boiling point is Not applicable..