Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Line Marking Paint Yellow
- Product Code
- LMY
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Linemarker Paint
Manufacturers & Suppliers
TYGRIS Ltd
manufacturer
31 Kyle Road, Irvine Industrial Estate, Irvine, North Ayrshire, KA12 8LE
+44 (0) 1294 311066
Emergency Contacts
Emergency Contact
+44 (0) 1294 311066
Monday to Friday: 07:30am to 16:15pm
NHS
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| PETROLEUM GASES, LIQUEFIED; PETROLEUM GAS EC: 270-704-2 | 68476-85-7 | 30 - 60% | Yes |
| ACETONE EC: 200-662-2 | 67-64-1 | 10 - 30% | Yes |
| Hydrocarbons, C9, aromatics EC: 918-668-5 | --- | 10 - 30% | Yes |
| Titanium dioxide (White colour) EC: 236-675-5 | 13463-67-7 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If spray/mist has been inhaled, proceed as follows. Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. If breathing stops, provide artificial respiration. Keep affected person warm and at rest. Get medical attention immediately.
Remove contaminated clothing immediately and wash skin with soap and water.
Rinse immediately with plenty of water. Remove any contact lenses and open eyelids wide apart. Continue to rinse for at least 15 minutes and get medical attention.
Rinse mouth thoroughly with water. Do not induce vomiting. Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Extinguish with foam, carbon dioxide, dry powder or water fog.
Containers can burst violently or explode when heated, due to excessive pressure build-up. Vapours are heavier than air and may spread near ground and travel a considerable distance to a source of ignition and flash back. Containers can burst violently or explode when heated, due to excessive pressure build-up. The product is extremely flammable. Forms explosive mixtures with air.
Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk. Use water to keep fire exposed containers cool and disperse vapours.
Firefighter Protection
Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of vapours.
Leave small quantities to evaporate, if safe to do so.
Avoid the spillage or runoff entering drains, sewers or watercourses.
Eliminate all sources of ignition. No smoking, sparks, flames or other sources of ignition near spillage. Provide adequate ventilation. Leave small quantities to evaporate, if safe to do so. Do not allow material to enter confined spaces, due to the risk of explosion. Absorb spillage with non-combustible, absorbent material.
Materials: non-combustible, absorbent material
Related Products
Similar products with comparable safety profiles
Oil Zone Marking Paint Interior/Exterior Yellow
---
MARKER PEN - Yellow
UFI: WAHY-R8SH-U00U-1JFG
COLORMARK LINEMARKER YELLOW 500 ML
---
edding Paint Marker-Ink (yellow)
---
Davidson Marking System Yellow Dye all sizes
CAS: 5468-75-7
Marking Chalk Blue
---
Pro-Line® HP Paint Markers
---
Linemarker Paint - All Colours
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Read and follow manufacturer's recommendations. Keep away from heat, sparks and open flame. Eliminate all sources of ignition. Do not spray on a naked flame or any incandescent material.
Store at moderate temperatures in dry, well ventilated area. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep away from heat, sparks and open flame. Eliminate all sources of ignition. Do not spray on a naked flame or any incandescent material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Avoid inhalation of vapours and spray/mists. Observe any occupational exposure limits for the product or ingredients.
Due to the packaging form, aerosol, risk of skin contact is small. Chemical-resistant, impervious gloves complying with an approved standard should be worn if a risk assessment indicates skin contact is possible. The most suitable glove should be chosen in consultation with the glove supplier/manufacturer, who can provide information about the breakthrough time of the glove material.
Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible. The following protection should be worn: Chemical splash goggles.
If ventilation is inadequate, suitable respiratory protection must be worn.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal ambient temperatures and when used as recommended.
Stable at normal ambient temperatures and when used as recommended.
Does not decompose when used and stored as recommended.
Heat, sparks, flames.
oxidising materials
Does not decompose when used and stored as recommended. Thermal decomposition or combustion products may include the following substances: Toxic and corrosive gases or vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not applicable.
EmS F-D, S-U
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Line Marking Paint Yellow?
The signal word is danger.
What is the physical form of Line Marking Paint Yellow?
Line Marking Paint Yellow is a aerosol. appearing as aerosol. with conforms to standard color. It has organic solvents. odor.
What is Line Marking Paint Yellow used for?
Linemarker Paint
What are the hazard statements for Line Marking Paint Yellow?
This substance has 5 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: may burst if heated.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.