NextSDS Logo
Safety Data Sheet EN

Stearic acid for synthesis

CAS 57-11-4

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Stearic acid for synthesis
Product Code
8.00673
Chemical Name
Stearic acid

Regulatory Identifiers

CAS Number
57-11-4 Check regulations →
REACH No.
01-2119543894-28-XXXX

Identified Uses

Chemical for synthesis

Manufacturers & Suppliers

M

Merck Life Science BV

manufacturer

Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Notes

No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most).

Immediate Medical Attention

Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of vapours/aerosols or dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

No special precautionary measures necessary.

Cleanup methods

Observe possible material restrictions (see sections 7 and 10). Take up with suitable equipment. Dispose of properly. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Full contact Manufacturer : KCL 741 Dermatril® L Material : Nitrile rubber Break through time : 480 min Glove thickness : 0,11 mm Protective index : Splash contact Manufacturer : KCL 741 Dermatril® L Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts/vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type ABEK-P type: The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

No special precautionary measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
Wax like
Odor
mild
Odor Threshold
---
Ph
---
Melting Point
69,4 °C
Boiling Point
383 - 385,8 °C (1.013 hPa) (ECHA)
Flash Point
ca. 200 °C(1.013 hPa) Method: ASTM D 92, Cleveland open cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
ca. 400 - 500 kg/m³
Density
0,845 g/cm³
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
395 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
284,48 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
9,87 mPa.s (70 °C)
Kinematic Viscosity
12 mm²/s (70 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Risk of dust explosion. Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.

Hazardous reactions

Violent reactions possible with: - Strong oxidizing agents - Reducing agents - strong alkalis

Avoid

Strong heating.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Stearic acid for synthesis?

The signal word is no signal word.

What is the physical form of Stearic acid for synthesis?

Stearic acid for synthesis is a solid with white color. It has mild odor.

What is Stearic acid for synthesis used for?

Chemical for synthesis

What is the melting point of Stearic acid for synthesis?

The melting point is 69,4 °C and the boiling point is 383 - 385,8 °C (1.013 hPa) (ECHA).