Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Schiff's reagent, for microscopy
- Product Code
- X900
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemical Laboratory and analytical use
Uses advised against
Do not use for products which come into contact with foodstuffs. Do not use for private purposes (household). Food, drink and animal feeding-stuffs.
Manufacturers & Suppliers
Carl Roth GmbH + Co. KG
manufacturer
Schoemperlenstr. 3-5, D-76185 Karlsruhe, Germany
+49 (0) 721 - 56 06 0
http://www.carlroth.de
Emergency Contacts
Giftzentrale München
+49/(0)89 19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice.
Rinse skin with water/shower.
Rinse cautiously with water for several minutes. In all cases of doubt, or when symptoms persist, seek medical advice.
In case of accident or unwellness, seek medical advice immediately (show directions for use or safety data sheet if possible).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
co-ordinate firefighting measures to the fire surroundings! water spray, alcohol resistant foam, dry extinguishing powder, BC-powder, carbon dioxide (CO₂)
water jet
Non-combustible.
Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Avoid contact with skin, eyes and clothes. Do not breathe vapour/spray.
Retain contaminated washing water and dispose of it.
Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents). Place in appropriate containers for disposal.
Materials: sand, diatomaceous earth, acid- or universal binding agents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provide adequate ventilation. Avoid exposure.
Keep container tightly closed in a cool place.
Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from measurements at 22°C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide. Type of material: NBR (Nitrile rubber). Material thickness: >0,11 mm. Breakthrough times of the glove material: >480 minutes (permeation: level 6).
Use safety goggle with side protection.
Respiratory protection necessary at: Aerosol or mist formation. Type: E (against acidic gases like sulphur dioxide or hydrogen chloride, colour code: Yellow). Observe the wear time limits according GefStoffV in combination with the rules for using respiratory protection apparatus (DGUV-Rule 112/190).
Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Substance or mixture corrosive to metals.
Violent reaction with: strong oxidiser, Strong alkali
There are no specific conditions known which have to be avoided.
different metals
Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1789
- Shipping Name
- HYDROCHLORIC ACID
- Transport Class
- 8
- Packing Group
- III
Provisions for dangerous goods (ADR) should be complied within the premises.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Schiff's reagent, for microscopy?
The signal word is danger.
What is the physical form of Schiff's reagent, for microscopy?
Schiff's reagent, for microscopy is a liquid with colourless color. It has stinging odor.
What is Schiff's reagent, for microscopy used for?
Laboratory chemical Laboratory and analytical use
What are the hazard statements for Schiff's reagent, for microscopy?
This substance has 2 hazard statements:
- H290: May be corrosive to metals
- H350: May cause cancer
What is the melting point of Schiff's reagent, for microscopy?
The melting point is not determined and the boiling point is ~ -100 °C.