Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Wall repair paste
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Wall repair.
Uses advised against
None.
Manufacturers & Suppliers
Shenzhen Shi Baochen Shidai Maoyi Youxian Gongsi
manufacturer
12D, Building B6, TCL Science Park, No. 1001 Zhongshanyuan Road, Shuguang Community, Xili Street, Nanshan District, Shenzhen
18682059139
Emergency Contacts
Emergency Contact
18682059139
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Barium sulfate EC: 231-784-4 | 7727-43-7 | 30% | No |
| Calcium carbonate EC: 207-439-9 | 471-34-1 | 30% | No |
| Water EC: 231-791-2 | 7732-18-5 | 20% | No |
| 2-Propenoic acid, polymer with ethenylbenzene EC: 607-532-8 | 25085-34-1 | 10% | No |
| Ethylene glycol EC: 203-473-3 | 107-21-1 | 3% | No |
| Dispersant EC: 203-916-0 | 111-86-4 | 3% | No |
| Hydroxyethyl Cellulose EC: 618-387-5 | 9004-62-0 | 2% | No |
| Fumed Silica EC: 601-216-3 | 112945-52-5 | 2% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move victim into fresh air. If breathing is difficult, give oxygen. Do not use mouth to mouth resuscitation if victim ingested or inhaled the substance. If not breathing, give artificial respiration and consult a physician immediately.
Take off contaminated clothing and shoes immediately. Wash off with plenty of soap and water for at least 15 minutes and consult a physician if feel uncomfortable.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician if feel uncomfortable.
Never give anything by mouth to an unconscious person. Call a physician or Poison Control Center immediately.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing media suitable for surrounding area.
There is no restriction on the type of extinguisher which may be used.
Development of hazardous combustion gases or vapor possible in the event of fire. Not considered a significant fire risk, however containers may burn.
Fight fire from a safe distance, with adequate cover.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus (MSHA/NIOSH approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Remove all sources of ignition. Take precautionary measures against static discharges. Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. Use personal protective equipment, do not breathe dust/fume. Prevent further leakage or spillage if safe to do so. Discharge into the environment must be avoided. Keep leaks in a ventilated place. Cut off the source of the leak as much as possible. Isolation of contaminated areas and restrictions on access. Collect the spill with a clean shovel and place it in a clean, dry, loosely closed container and move the container away from the leak.
Prevent further leakage or spillage if safe to do so. Discharge into the environment must be avoided.
Collect the spill with a clean shovel and place it in a clean, dry, loosely closed container and move the container away from the leak.
Materials: clean shovel, clean, dry, loosely closed container
Related Products
Similar products with comparable safety profiles
Plaster Wall Patch Dry Mix
---
Wallboard Joint Compound
---
Drydex Spackling Paste
---
Wallboard Joint Compound (Ready to Use)
---
Patching Plaster Ready To Use
---
Spackling Paste (Ready To Use)
---
Drydex Spackling Paste (RTU) Squeeze Tube
---
Perfax Heavy Duty Wallpaper Adhesive
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handling is performed in a well ventilated place. Wear suitable protective equipment. Avoid contact with skin and eyes. Keep away from heat/sparks/open flames/ hot surfaces.
Keep containers tightly closed. Keep containers in a dry, cool and well-ventilated place. Keep away from heat/sparks/open flames/hot surfaces. Store away from incompatible materials and foodstuff containers.
Keep away from heat/sparks/open flames/ hot surfaces.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under proper operation and storage conditions.
Contact with incompatible substances can cause decomposition or other chemical reactions.
In contact with oxidants causes severe reactions, and may cause a fire or explosion.
Incompatible materials, heat, flame and spark.
Oxidants, alkali metals, alkaline earth metals and aluminum.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
Chronic aquatic toxicity
Persistence and degradability
Persistence and degradability
Persistence and degradability
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Mobility in soil
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recommend the use of incineration disposal.
Refer to section waste chemicals and contaminated packaging.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Transport vehicles should be equipped with the appropriate variety and quantity of fire equipment and emergency equipment leakage during transport. Before transport, should be preceded by checking whether container integrity, sealing. The transport unit must be placarded and marked in accordance with relevant transporting requirements.
Transport vehicles should be equipped with the appropriate variety and quantity of fire equipment and emergency equipment leakage during transport. Before transport, should be preceded by checking whether container integrity, sealing. The transport unit must be placarded and marked in accordance with relevant transporting requirements.
Transport vehicles should be equipped with the appropriate variety and quantity of fire equipment and emergency equipment leakage during transport. Before transport, should be preceded by checking whether container integrity, sealing. The transport unit must be placarded and marked in accordance with relevant transporting requirements.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Wall repair paste?
The signal word is danger.
What is the physical form of Wall repair paste?
Wall repair paste is a white paste appearing as white paste with white color. It has odorless odor.
What is the solubility of Wall repair paste?
No information available
What is Wall repair paste used for?
Wall repair.
What are the hazard statements for Wall repair paste?
This substance has 2 hazard statements:
- H315: Causes skin irritation
- H318: Causes serious eye damage
What is the melting point of Wall repair paste?
The melting point is No information available and the boiling point is 100.5 °C.