NextSDS Logo
Safety Data Sheet EN

HiTEC® 12210M Performance Additive

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 12210M Performance Additive
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A
UFI Code
WJ52-123S-FX6Y-2N5S

Identified Uses

Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional

Manufacturers & Suppliers

A

Afton Chemical Limited

manufacturer

Euro-Tech Centre Alma Court, 50 London Road, Bracknell, RG12 2UW, England

+44 1344 304141

A

Afton Chemical S.R.L. (Woluwe)

manufacturer

Lenneke Marelaan, 8 B-1932 St-Stevens-Woluwe Belgium

+32 2 715 2211

A

Afton Chemical SPRL (Feluy Plant)

manufacturer

Rue de Scoufflény, 50 B-7191 Ecaussinnes Lalaing, Belgium

+32 67 286211

Emergency Contacts

Emergency Contact

+43-13649237

Emergency Contact

+421-233057972

Emergency Contact

+32-28083237

Emergency Contact

+38-618888016

Emergency Contact

+359-32570104

Emergency Contact

+46-852503403

Emergency Contact

+385-17776920

Emergency Contact

+41-435082011

Emergency Contact

+420-228880039

Emergency Contact

+380-947101374

Emergency Contact

+45-69918573

Emergency Contact

+44-8708200418

Emergency Contact

+358-942419014

Emergency Contact

+1-703-527-3887

Emergency Contact

+33-975181407

Emergency Contact

+65-3158-1349

Emergency Contact

+36-18088425

Emergency Contact

+61-290372994

Emergency Contact

+353-19014670

Emergency Contact

4001-204937

Emergency Contact

+39-0245557031

Emergency Contact

+(91)-22-3354 3594

Emergency Contact

+352-20202416

Emergency Contact

+81-345209637

Emergency Contact

+31-858880596

Emergency Contact

00-308-13-2549

Emergency Contact

+47-21930678

Emergency Contact

+1-703-741-5979

Emergency Contact

+48-223988029

Emergency Contact

1-800-424-9300

Emergency Contact

+351-308801773

Emergency Contact

+32 (0)70 245 245

Emergency Contact

+31 (0)30 2748888

Emergency Contact

+45 8212 1212

Emergency Contact

+47 22 59 13 00

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

+351 800 250 250

Emergency Contact

+30 210 779 3777

Emergency Contact

+40 (0)21 318 36 06

8am – 3pm

Emergency Contact

+34 91 562 04 20

Emergency Contact

+371 67042473

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P403 Store in a well-ventilated place.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 25 - 35% No
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 15 - 25% Yes
Phosphorodithioic acid, mixed O,O-bis (2-ethylhexyl and iso-Bu and iso-Pr) esters, zinc salts EC: 288-917-4 85940-28-9 5 - 10% Yes
Alkyl esters of alkyl phenate alkanoic acid --- 5 - 10% Yes
Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 --- 3 - 5% Yes
Alcohols, C12-14, ethoxylated(even numbered) EC: 500-213-3 --- 0.3 - 0.5% Yes
phenol, (tetrapropenyl) derivatives EC: 616-100-8 74499-35-7 0.1 - 0.3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Get medical attention if irritation occurs. Get medical attention if adverse health effects persist or are severe. If unconscious, get medical attention immediately.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical orCO₂.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst. This material is harmful to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Take precautions to limit storage vessel surface temperature to below 121°C (250°F).

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate personnel surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and wellventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer’s directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid. [Viscous]
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown. [Dark]
Colour Intensity
---
Form
---
Odor
Not available.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Closed cup: 135°C [Pensky-Martens. Minimum]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
0.948
Bulk Density
---
Density
0.947 g/cm³
Flammability
Not applicable (liquid).
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Not available.
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C): 19.97 cm²/s (1997 cSt); 108 cSt @ 100°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Under recommended handling and storage conditions the product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

High temperatures, sparks and open flames.

Incompatible

Strong oxidizing and reducing agents.

Decomposition

Hydrogen sulfide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Product/ingredient name: Distillates (petroleum), hydrotreated heavy paraffinic Result: Acute EL50 >10000 mg/l, Species: Daphnia - Daphnia magna, Exposure: 48 hours, Remarks: Based on data for a similar substance. Result: Acute LL50 >100 mg/l, Species: Fish - Pimephales promelas, Exposure: 96 hours, Remarks: Based on data for a similar substance. Result: Chronic NOEL ≥100 mg/l, Species: Algae - Pseudokirchneriella subcapitata, Exposure: 72 hours, Remarks: Based on data for a similar substance. Result: Chronic NOEL 10 mg/l, Species: Daphnia - Daphnia magna, Exposure: 21 days, Remarks: Based on data for a similar substance. Result: Chronic NOEL 1000 mg/l, Species: Fish - Oncorhynchus mykiss, Exposure: 14 days, Remarks: QSAR result.

12.1 Toxicity

Product/ingredient name: Distillates (petroleum), solvent-dewaxed heavy paraffinic Acute EL50 >10000 mg/l, Daphnia - Daphnia magna, 48 hours, Based on data for a similar substance. Acute LL50 >100 mg/l, Fish - Pimephales promelas, 96 hours, Based on data for a similar substance. Chronic NOEL ≥100 mg/l, Algae - Pseudokirchneriella subcapitata, 72 hours, Based on data for a similar substance. Chronic NOEL 10 mg/l, Daphnia - Daphnia magna, 21 days, Based on data for a similar substance. Chronic NOEL 1000 mg/l, Fish - Oncorhynchus mykiss, 14 days, QSAR result.

12.1 Toxicity

Product/ingredient name: Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Bu and iso-Pr) esters, zinc salts Acute EL50 2.1 mg/l, Algae - Selenastrum capricornutum, 96 hours, Based on data for a similar substance. Acute EL50 5.4 mg/l, Daphnia - Daphnia magna, 48 hours, Based on data for a similar substance. Acute EL50 >10000 mg/l, Micro-organism, 3 hours, Based on data for a similar substance. Acute LL50 4.5 mg/l, Fish - Oncorhynchus mykiss, 96 hours, Based on data for a similar substance. Chronic NOEL 1 mg/l, Algae - Selenastrum capricornutum, 96 hours, Based on data for a similar substance. Chronic NOEL 0.4 mg/l, Daphnia - Daphnia magna, 21 days, Based on data for a similar substance.

12.1 Toxicity

|Product/ingredient name|Result|Species|Exposure|Remarks| |Alkyl esters of alkyl phenate alkanoic acid|Acute EL50 >3 mg/l|Algae - Desmodesmus subspicatus|72 hours|No effects at saturation.| ||Acute EL50 >0.9 mg/l|Daphnia - Daphnia magna|48 hours|No effects at|

12.1 Toxicity

Acute IC50 >100 mg/l (Micro-organism, 3 hours); Acute LC50 >74 mg/l (Fish - Danio rerio, 96 hours); Chronic NOEL >3 mg/l (Algae - Desmodesmus subspicatus, 72 hours); Chronic NOEL >0.001 mg/l (Fish - Danio rerio, 36 days). No effects at saturation.

12.1 Toxicity

Product/ingredient name: Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased Result: Acute EL50 >500 mg/l, Species: Algae - Pseudokirchneriella subcapitata, Exposure: 96 hours Result: Acute EL50 >1000 mg/l, Species: Daphnia - Daphnia magna, Exposure: 48 hours Result: Acute EL50 >10000 mg/l, Species: Micro-organism, Exposure: 3 hours (Based on data for a similar substance.) Result: Acute LL50 >1000 mg/l, Species: Fish - Pimephales promelas, Exposure: 96 hours

12.1 Toxicity

Product/ingredient name: Alcohols, C12-14, ethoxylated (even numbered) 1-2.5EO Acute EL50 0.41 mg/l, Algae - Pseudokirchneriella subcapitata, 72 hours, Based on data for a similar substance. Acute EL50 0.39 mg/l, Daphnia - Daphnia magna, 48 hours, Based on data for a similar substance. Acute EL50 >2 mg/l, Micro-organism, 5 hours, Based on data for a similar substance. Acute LC50 0.876 mg/l, Fish - Danio rerio, 96 hours, Based on data for a similar substance. Chronic NOEC 0.77 mg/l, Daphnia - Daphnia magna, 21 days, Based on data for a similar substance. Chronic NOEC 0.16 mg/l, Fish - Pimephales promelas, 10 days, Based on data for a similar substance. Chronic NOEL 0.31 mg/l, Algae - Pseudokirchneriella subcapitata, 72 hours, Based on data for a similar substance.

12.1 Toxicity

Product/ingredient name: phenol, (tetrapropenyl)derivatives Result: Acute EL50 0.36 mg/l, Species: Algae - Desmodesmus subspicatus, Exposure: 72 hours Result: Acute EL50 0.037 mg/l, Species: Daphnia - Daphnia magna, Exposure: 48 hours Result: Acute EL50 >1000 mg/l, Species: Micro-organism, Exposure: 3 hours Result: Acute LL50 40 mg/l, Species: Fish - Pimephales promelas, Exposure: 96 hours Result: Chronic NOEL 0.07 mg/l, Species: Algae - Desmodesmus subspicatus, Exposure: 72 hours Result: Chronic NOEL 0.0037 mg/l, Species: Daphnia - Daphnia magna, Exposure: 21 days

12.2 Persistence and degradability

|**Product/ingredient name**|**Test**|**Result**|**Remarks**| |Distillates (petroleum), hydrotreated heavy paraffinic Distillates (petroleum), solvent- dewaxed heavy paraffinic|OECD 301F Ready Biodegradability - Manometric Respirometry Test OECD 301F Ready Biodegradability - Manometric Respirometry Test|31 % - Not readily - 28 days 31 % - Not readily - 28 days|Based on data for a similar substance. Based on data for a similar substance.|

12.2 Persistence and degradability

Distillates (petroleum), solvent-dewaxed heavy paraffinic|OECD 301F Ready Biodegradability - Manometric Respirometry Test OECD 301F Ready Biodegradability - Manometric Respirometry Test|31 % - Not readily - 28 days 31 % - Not readily - 28 days|Based on data for a similar substance. Based on data for a similar substance.

12.2 Persistence and degradability

|Product/ingredient name|Test|Result|Remarks| |Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Bu and iso-Pr) esters, zinc salts|OECD 301B Ready Biodegradability - CO₂ Evolution Test|1.5 % - Not readily - 28 days|Based on data for a similar substance.|

12.2 Persistence and degradability

|Product/ingredient name|Test|Result|Remarks| |Alkyl esters of alkyl phenate alkanoic acid|OECD 301B Ready Biodegradability - CO₂Evolution Test|2 % - Not readily - 28 days|-|

12.2 Persistence and degradability

|**Product/ingredient name**|**Test**|**Result**|**Remarks**| |Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased|OECD 301B Ready Biodegradability - CO₂Evolution Test|13.4 % - Not readily - 28 days|Based on data for a similar substance.|

12.2 Persistence and degradability

Alcohols, C12-14, ethoxylated (even numbered) 1-2.5EO | OECD 301F Ready Biodegradability - Manometric Respirometry Test | 95 % - Readily - 28 days | Based on data for a similar substance.

12.2 Persistence and degradability

|Product/ingredient name|Test|Result|Remarks| |phenol, (tetrapropenyl) derivatives|OECD 301B Ready Biodegradability - CO₂Evolution Test|6 to 25 % - Not readily - 28 days|-|

12.3 Bioaccumulative potential

Conclusion/Summary : Based on available data, the classification criteria are not met. |Product/ingredient name|LogPow|BCF||Potential|

12.3 Bioaccumulative potential

Product/ingredient name: Alkyl esters of alkyl phenate alkanoic acid; LogPow: 9.2; BCF: 260; Potential: low

12.3 Bioaccumulative potential

|**Product/ingredient name**|**LogPow**|**BCF**||**Potential**| Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased phenol, (tetrapropenyl) derivatives|9.2 9.5 -|260 - 289 to 1601||low high high|

Based on available data, the classification criteria are not met.

12.3 Bioaccumulative potential

|**Product/ingredient name**|**LogPow**|**BCF**||**Potential**| phenol, (tetrapropenyl) derivatives|9.2 9.5 -| 260 - 289 to 1601||low high high|

Based on available data, the classification criteria are not met.

12.4 Mobility in soil

Mobility: Not available. Soil/water partition coefficient (KOC): Not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

13 02 05* mineral-based non-chlorinated engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 12210M Performance Additive?

The signal word is no signal word.

What is the physical form of HiTEC® 12210M Performance Additive?

HiTEC® 12210M Performance Additive is a liquid. [viscous] with brown. [dark] color. It has not available. odor.

What is the solubility of HiTEC® 12210M Performance Additive?

Not available.

What is HiTEC® 12210M Performance Additive used for?

Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional

What are the hazard statements for HiTEC® 12210M Performance Additive?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of HiTEC® 12210M Performance Additive?

The melting point is Not available. and the boiling point is Not available..