Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 7420 Performance Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- D0V4-CUTT-RM60-YV6X
Identified Uses
Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical S.R.L. (Feluy Plant)
manufacturer
Rue de Scouffény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Afton Chemical India PVT Ltd
manufacturer
Lotus Corporate Park, 7th Floor, A Wing, Ram Mandir Lane, Western Express Highway, Goregaon East, Mumbai 400063 India
+91 22 6728 0200
Emergency Contacts
Emergency Contact
+43 1 364 92 37
24 hours a day, 7 days a week
Emergency Contact
+32 2 808 32 37
24 hours a day, 7 days a week
Emergency Contact
+359 32 570 104
24 hours a day, 7 days a week
Emergency Contact
+385 1 7776 920
24 hours a day, 7 days a week
Emergency Contact
+420 228 880 039
24 hours a day, 7 days a week
Emergency Contact
+45 69 91 85 73
24 hours a day, 7 days a week
Emergency Contact
+358 9 42725036
24 hours a day, 7 days a week
Emergency Contact
+33 9 75 18 14 07
24 hours a day, 7 days a week
Emergency Contact
0800 1817059
24 hours a day, 7 days a week
Emergency Contact
+30 21 1176 8478
24 hours a day, 7 days a week
Emergency Contact
+36 1 808 8425
24 hours a day, 7 days a week
Emergency Contact
+91 8071 279 207
24 hours a day, 7 days a week
Emergency Contact
+353 1 901 4670
24 hours a day, 7 days a week
Emergency Contact
+39 02 4555 7031
24 hours a day, 7 days a week
Emergency Contact
+352 20 20 24 16
24 hours a day, 7 days a week
Emergency Contact
+31 85 888 0596
24 hours a day, 7 days a week
Emergency Contact
+234 2012 278 883
24 hours a day, 7 days a week
Emergency Contact
+48 22 398 80 29
24 hours a day, 7 days a week
Emergency Contact
+351 308 801 773
24 hours a day, 7 days a week
Emergency Contact
+421 2330 579 72
24 hours a day, 7 days a week
Emergency Contact
+386 1 888 80 16
24 hours a day, 7 days a week
Emergency Contact
080 001 4676
24 hours a day, 7 days a week
Emergency Contact
+34 931 768 545
24 hours a day, 7 days a week
Emergency Contact
+46 8 525 034 03
24 hours a day, 7 days a week
Emergency Contact
+41 435 082 011
24 hours a day, 7 days a week
Emergency Contact
+44 20 3807 3798
24 hours a day, 7 days a week
Emergency Contact
+1 703 527 3887
24 hours a day, 7 days a week
Emergency Contact
+44 20 3885 0382
24 hours a day, 7 days a week
Emergency Contact
+65 3163 8374
24 hours a day, 7 days a week
Emergency Contact
+55 55 8526 4930
24 hours a day, 7 days a week
Emergency Contact
+55-11 4349 1359
24 hours a day, 7 days a week
Emergency Contact
+1 800 424 9300
24 hours a day, 7 days a week
Emergency Contact
+43 1 406 43 43
Emergency Contact
+32 (0)70 245 245
Emergency Contact
+359 2 9154 233
Emergency Contact
+3851 2348 342
Emergency Contact
+357 1401
Emergency Contact
+420 224 91 92 93
Emergency Contact
+45 8212 1212
Emergency Contact
+372 16662
Emergency Contact
+33 (0)1 45 42 59 59
Emergency Contact
+30 210 779 3777
Emergency Contact
+36 80 201 199
Emergency Contact
+354 112
Emergency Contact
+39 800 883 300
Emergency Contact
+39 055 794 7819
Emergency Contact
+39 800 183 459
Emergency Contact
+39 02 6610 1029
Emergency Contact
+39 081 545 3333
Emergency Contact
+39 0382 24444
Emergency Contact
+39 06 305 4343
Emergency Contact
+39 06 4997 8000
Emergency Contact
+39 06 6859 3726
Emergency Contact
+39 800 011 858
Emergency Contact
+371 67042473
Emergency Contact
+370 (85) 236 2052
Emergency Contact
+352 8002 5500
Emergency Contact
+31 (0)88 755 8000
Emergency Contact
+47 22 59 13 00
Emergency Contact
+351 800 250 250
Emergency Contact
+40 (0)21 318 36 06
8am – 3pm
Emergency Contact
+421 2 5477 4166
Emergency Contact
+386 112
Emergency Contact
+34 91 562 04 20
Emergency Contact
+46 112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 | 122384-87-6 | 55 - 65% | Yes |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 10 - 15% | No |
| Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 | 64742-56-9 | 10 - 15% | No |
| Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 | 64742-55-8 | 10 - 15% | No |
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | 64742-65-0 | 10 - 15% | Yes |
| phenol, (tetrapropenyl) derivatives EC: 616-100-8 | 74499-35-7 | 1 - 2.5% | Yes |
| ethane-1,2-diol EC: 203-473-3 | 107-21-1 | 1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: May cause damage to organs following a single exposure if inhaled. Adverse symptoms may include the following: reduced fetal weight, increase in fetal deaths, skeletal malformations.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Get medical attention. If necessary, call a poison center or physician. Wash clothing before reuse. Clean shoes thoroughly before reuse. Continue to rinse for at least 15 minutes.
Symptoms: May cause damage to organs following a single exposure in contact with skin. Adverse symptoms may include the following: reduced fetal weight, increase in fetal deaths, skeletal malformations.
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes.
Symptoms: No known significant effects or critical hazards. No specific data.
Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: May cause damage to organs following a single exposure if swallowed. Adverse symptoms may include the following: reduced fetal weight, increase in fetal deaths, skeletal malformations.
Immediate Medical Attention
Get medical attention following exposure or if feeling unwell. If necessary, call a poison center or physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO₂.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst. This material may cause long lasting harmful effects to aquatic life.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Collect spillage.
Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 9450 Performance Additive
UFI: FFP9-JQE2-QK67-P46W
HiTEC® 9450 Performance Additive
UFI: FFP9-JQE2-QK67-P46W
HiTEC® 8768 Performance Additive
UFI: RC8K-UD6N-635K-5RYX
HiTEC® 9325H Performance Additive
---
HiTEC® 9325H Performance Additive
UFI: P39T-98W4-KP35-QME5
HiTEC® 9490 Performance Additive
UFI: 72TV-F4UF-T15P-4NEG
HiTEC® 9490 Performance Additive
---
HiTEC® 2240S Performance Additive
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Avoid exposure during pregnancy. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Hydrogen sulfide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Results of PMT and vPvM assessment
The product does not meet the criteria to be considered as a PMT or vPvM.
12.5 Results of PBT and vPvB assessment
The product does not meet the criteria to be considered as a PBT or vPvB.
12.6 Endocrine disrupting properties
May cause endocrine disruption in the environment.
12.7 Other adverse effects
No known significant effects or critical hazards.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (Dodecylphenol)
- Transport Class
- 9
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product contains only components that have been either registered, are exempt from registration, are regarded as registered or are not subject to registration according to Regulation (EC) No. 1907/2006 (REACH) and amendments.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 7420 Performance Additive?
The signal word is danger.
What is the physical form of HiTEC® 7420 Performance Additive?
HiTEC® 7420 Performance Additive is a liquid. [viscous] appearing as liquid. [viscous] with brown. [dark] color. It has petroleum. odor.
What is the solubility of HiTEC® 7420 Performance Additive?
Not soluble (cold water)
What is HiTEC® 7420 Performance Additive used for?
Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial
What are the hazard statements for HiTEC® 7420 Performance Additive?
This substance has 5 hazard statements:
- EUH380: May cause endocrine disruption in humans.
- EUH430: May cause endocrine disruption in the environment.
- H360F: May damage fertility.
- H370: May cause damage to organs.
- H413: May cause long lasting harmful effects to aquatic life.
What is the melting point of HiTEC® 7420 Performance Additive?
The melting point is Not available. and the boiling point is Not available..