Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 46002 Diesel Fuel Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- W7JN-P0EC-K00V-DAMP
Identified Uses
Industrial. Formulation and blending of fuel additives and fuels.
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical S.R.L. (Feluy Plant)
manufacturer
Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Emergency Contacts
Emergency Contact
+43-13649237
24 hours a day, 7 days a week
Emergency Contact
+32-28083237
24 hours a day, 7 days a week
Emergency Contact
+359-32570104
24 hours a day, 7 days a week
Emergency Contact
+385-17776920
24 hours a day, 7 days a week
Emergency Contact
+420-228880039
24 hours a day, 7 days a week
Emergency Contact
+45-69918573
24 hours a day, 7 days a week
Emergency Contact
+358-942419014
24 hours a day, 7 days a week
Emergency Contact
+33-975181407
24 hours a day, 7 days a week
Emergency Contact
+49-69-6435-08409
24 hours a day, 7 days a week
Emergency Contact
+36-18088425
24 hours a day, 7 days a week
Emergency Contact
+353-19014670
24 hours a day, 7 days a week
Emergency Contact
+39-0245557031
24 hours a day, 7 days a week
Emergency Contact
+352-20202416
24 hours a day, 7 days a week
Emergency Contact
+31-858880596
24 hours a day, 7 days a week
Emergency Contact
+47-21930678
24 hours a day, 7 days a week
Emergency Contact
+48-223988029
24 hours a day, 7 days a week
Emergency Contact
+351-308801773
24 hours a day, 7 days a week
Emergency Contact
+421-233057972
24 hours a day, 7 days a week
Emergency Contact
+38-618888016
24 hours a day, 7 days a week
Emergency Contact
+46-852503403
24 hours a day, 7 days a week
Emergency Contact
+41-435082011
24 hours a day, 7 days a week
Emergency Contact
+380-947101374
24 hours a day, 7 days a week
Emergency Contact
+44-8708200418
24 hours a day, 7 days a week
Emergency Contact
+1-703-527-3887
24 hours a day, 7 days a week
Emergency Contact
+65-3158-1349
24 hours a day, 7 days a week
Emergency Contact
+61-290372994
24 hours a day, 7 days a week
Emergency Contact
4001-204937
24 hours a day, 7 days a week
Emergency Contact
+(91)-22-3354 3594
24 hours a day, 7 days a week
Emergency Contact
+81-345209637
24 hours a day, 7 days a week
Emergency Contact
00-308-13-2549
24 hours a day, 7 days a week
Emergency Contact
+1-703-741-5979
24 hours a day, 7 days a week
Emergency Contact
1-800-424-9300
24 hours a day, 7 days a week
Emergency Contact
+32 (0)70 245 245
Emergency Contact
+45 8212 1212
Emergency Contact
+33 (0)1 45 42 59 59
Emergency Contact
+30 210 779 3777
Emergency Contact
+371 67042473
Emergency Contact
+43-13649237
Emergency Contact
+31 (0)30 2748888
Emergency Contact
+47 22 59 13 00
Emergency Contact
+351 800 250 250
Emergency Contact
+40 (0)21 318 36 06
8am – 3pm
Emergency Contact
+34 91 562 04 20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-ethylhexyl nitrate EC: 248-363-6 | 27247-96-7 | 75 - 85% | Yes |
| 2-ethylhexan-1-ol EC: 203-234-3 | 104-76-7 | 10 - 14% | Yes |
| Long-chain alkenyl amido alkyl ammonio acetate EC: 947-523-9 | --- | 1 - 3% | Yes |
| methyl-1H-benzotriazole EC: 249-596-6 | 29385-43-1 | 1 - 3% | Yes |
| amides, C18-unsatd., N-[3-(dimethylamine) propyl] EC: 800-353-8 | --- | 0.1 - 0.3% | Yes |
| Hydrocarbons, C10, aromatics, > 1% naphthalene EC: 919-284-0 | --- | 0.1 - 0.3% | Yes |
| Amines, polyethylenepoly-, tetraethylenepentamine fraction EC: 292-587-7 | --- | 0.1 - 0.3% | Yes |
| octamethylcyclotetrasiloxane EC: 209-136-7 | 556-67-2 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.
Symptoms: Harmful if inhaled. Inhalation of vapors may cause a sharp decrease in blood pressure with resulting loss of consciousness.
Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Get medical attention. If necessary, call a poison center or physician. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse. Continue to rinse for at least 15 minutes.
Symptoms: Harmful in contact with skin. Causes skin irritation. May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness.
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms: Causes serious eye irritation. Adverse symptoms may include the following: pain or irritation, watering, redness.
Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: Harmful if swallowed.
Immediate Medical Attention
Get medical attention if adverse health effects persist or are severe. If necessary, call a poison center or physician. If unconscious, get medical attention immediately.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO₂.
Do not use water jet.
Risk of explosion if heated under confinement. In a fire or if heated, a pressure increase will occur and the container may burst. This material is very toxic to aquatic life with long lasting effects.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. First move people out of line-of-sight of the scene and away from windows. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool. Fight fire from protected location or maximum possible distance. Do not fight fire when it reaches the material. Withdraw from fire and let it burn. Spray storage vessels with water to maintain temperature below 100°C/212°F.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents. Fire-fighters' protective clothing will only provide limited protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities. Collect spillage.
Collect spillage.
Materials: inert dry material, sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 46002 Diesel Fuel Additive
UFI: W7JN-P0EC-K00V-DAMP
HiTEC® 46200 Diesel Fuel Additive
UFI: AF47-HXKP-CV6W-5NG3
HiTEC® 46000 Fuel Additive
---
HiTEC® 46014 Fuel Additive
UFI: 1UUM-JX47-H68J-MESM
HiTEC 4678 Diesel Fuel Additive
---
HiTEC® 46100 Fuel Additive
UFI: 76EP-M050-S008-3HKX
HiTEC® 4247 Diesel Fuel Additive
UFI: QKWW-S7FV-P20W-G9JK
HiTEC® 4247 Diesel Fuel Additive
UFI: QKWW-S7FV-P20W-G9JK
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Keep away from heat. Empty containers retain product residue and can be hazardous. Do not reuse container. Do not heat the product.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep away from heat. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Do not heat the product.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Keep away from heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant. Approved/certified respirator with organic vapor cartridge.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Unstable at temperatures greater than 100°C/212°F.
No specific test data related to reactivity available for this product or its ingredients.
Hazardous reactions or instability may occur under certain conditions of storage or use. Conditions may include the following: heating under confinement Reactions may include the following: risk of explosion
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
Based on available data, the classification criteria are not met.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.5 Results of PBT and vPvB assessment
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (2-ethylhexyl nitrate)
- Transport Class
- 9
- Packing Group
- III
Do not heat the product.
Do not heat the product.
Do not heat the product.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product contains only components that have been either registered, are exempt from registration, are regarded as registered or are not subject to registration according to Regulation (EC) No.1907/2006 (REACH) and amendments.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 46002 Diesel Fuel Additive?
The signal word is warning.
What is the physical form of HiTEC® 46002 Diesel Fuel Additive?
HiTEC® 46002 Diesel Fuel Additive is a liquid. with pale. amber. color. It has characteristic. odor.
What is the solubility of HiTEC® 46002 Diesel Fuel Additive?
Not available.
What is HiTEC® 46002 Diesel Fuel Additive used for?
Industrial. Formulation and blending of fuel additives and fuels.
What are the hazard statements for HiTEC® 46002 Diesel Fuel Additive?
This substance has 5 hazard statements:
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of HiTEC® 46002 Diesel Fuel Additive?
The melting point is Not available. and the boiling point is Not available..