01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MPG USP
Product Code
61510
Synonyms
1,2-propanediol; alpha-propylene glycol; monopropylene glycol; propane-1,2-diol

Regulatory Identifiers

CAS Number
57-55-6 Check regulations →
EC Number
200-338-0 Check regulations →
REACH No.
01-2119456809-23-0006

Identified Uses

Manufacture of substance Distribution of substance Formulation & (re)packing of substances and mixtures Use in coatings Use in coatings Use in coatings Use in Cleaning Agents Use in Cleaning Agents Use in Cleaning Agents Functional Fluids Functional Fluids Functional Fluids Use in/as de-icing/anti-icing applications/agents Use in/as de-icing/anti-icing applications/agents Other Consumer Uses Use in laboratories Use in laboratories Mining chemicals Use as binders and release agents Use as binders and release agents Water treatment Water treatment Water treatment Production of polymers Rubber production and processing Use of fuel Use of fuel Agrochemical uses Agrochemical uses Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use

Uses advised against

No uses advised against known

Manufacturers & Suppliers

I

INEOS N.V.

global supplier

Haven 1053 - Nieuwe Weg 1, B-2070 Zwijndrecht

+32 3 250 91 11

I

INEOS Manufacturing Deutschland GmbH

manufacturer

Alte Strasse 201, D-50769 Köln

+49 221 35 55 22 22

Emergency Contacts

BIG

+32 14 58 45 45

24h/24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
propane-1,2-diol EC: 200-338-0 57-55-6 99% No

Notes

(2) Substance with a Community workplace exposure limit

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Symptoms: EXPOSURE TO HIGH CONCENTRATIONS: Dry/sore throat.

Skin contact

Rinse with water. Do not apply (chemical) neutralizing agents without medical advice. Take victim to a doctor if irritation persists.

Symptoms: Slight irritation. ON CONTINUOUS EXPOSURE/CONTACT: Red skin. Dry skin.

Eye contact

Rinse with water. Remove contact lenses, if present and easy to do. Continue rinsing. Do not apply (chemical) neutralizing agents without medical advice. Take victim to an ophthalmologist if irritation persists.

Symptoms: Redness of the eye tissue. Slight irritation.

Ingestion

Rinse mouth with water. Do not apply (chemical) neutralizing agents without medical advice. Consult a doctor/medical service if you feel unwell.

Symptoms: AFTER INGESTION OF HIGH QUANTITIES: Cramps/uncontrolled muscular contractions. Nausea. Abdominal pain.

Immediate Medical Attention

Depending on the victim's condition: doctor/hospital. Respiratory problems: consult a doctor/medical service. Take victim to a doctor if irritation persists. Take victim to an ophthalmologist if irritation persists. Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Small fire: Quick-acting ABC powder extinguisher, Quick-acting BC powder extinguisher, Quick-acting class B foam extinguisher, Quick-acting CO2 extinguisher. Major fire: Class B foam (alcohol-resistant), Water spray if puddle cannot expand.

Unsuitable media

Small fire: Water (quick-acting extinguisher, reel); risk of puddle expansion. Major fire: Water; risk of puddle expansion.

Specific hazards

Upon combustion: CO and CO2 are formed.

Instructions

Cool tanks/drums with water spray/remove them into safety.

Firefighter Protection

Gloves. Protective clothing. Heat/fire exposure: compressed air/oxygen apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Contain released product, pump into suitable containers. Plug the leak, cut off the supply.

Cleanup methods

Scoop absorbed substance into closing containers. Clean contaminated surfaces with an excess of water.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Gas/vapour heavier than air at 20°C. Observe normal hygiene standards. Keep container tightly closed.

Storage

Keep container tightly closed.

Hygiene

Observe normal hygiene standards.

Fire prevention

Keep away from naked flames/heat. Finely divided: keep away from ignition sources/sparks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Measure the concentration in the air regularly. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.

Hands

Protective gloves against chemicals (EN374). - materials (good resistance) Nitrile rubber, butyl rubber, natural rubber, polyethylene, PVC, polyethylene/ethylenevinylalcohol.

Eyes

Safety glasses.

Respiratory

Respiratory protection not required in normal conditions.

Skin/Body

Protective clothing.

Environmental

See headings 6.2, 6.3 and 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colourless
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Almost odourless
Odor Threshold
No data available
Ph
6.5 - 7.5 ; 50 %
Melting Point
< -20 °C ; Test data
Boiling Point
184 °C ; 1003.2 hPa ; Test data
Flash Point
104 °C ; Test data ; 1000.1 hPa
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
< 0.1 ; Butyl acetate
Vapor Pressure
0.2 hPa ; 20 °C ; Test data
Vapor Density
---
Relative Density
1.03 ; 20 °C ; Test data
Bulk Density
---
Density
1038 kg/m³
Flammability
Non-flammable
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
> 400 °C ; Test data ; 1000.1 hPa - 1014 hPa
Decomposition Temperature
No data available
Solubility
Water ; complete; Ethanol ; complete; Acetone ; complete; Ether ; 12 g/100 ml
Partition Coefficient
-1.07 ; Test data ; Equivalent to OECD 107 ; 20.5 °C
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
0.0434 Pa.s ; 25 °C
Kinematic Viscosity
Not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Hygroscopic.

Reactivity

Temperature above flashpoint: higher fire/explosion hazard.

Hazardous reactions

Reacts violently with (strong) oxidizers: (increased) risk of fire. Violent to explosive reaction with (strong) acids.

Avoid

Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks.

Incompatible

Oxidizing agents, reducing agents, (strong) acids, water/moisture.

Decomposition

Upon combustion: CO and CO2 are formed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

### MPG USP

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

No data available

12.6 Endocrine disrupting properties

No data available

12.7 Other adverse effects

No data available

12.1. Toxicity

12.1. Toxicity | | Parameter | Method | Value | Duration | Species | Test design | Fresh/salt water | Value determination | | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Acute toxicity fishes | LC50 | | 40613 mg/l | 96 h | Oncorhynchus mykiss | Static system | Fresh water | Experimental value | | Acute toxicity crustacea | LC50 | EPA 600/4-90/027 | 18340 mg/l | 48 h | Ceriodaphnia dubia | Static system | Fresh water | Experimental value | | Acute toxicity crustacea | LC50 | FIFRA 72-3 | 18800 mg/l | 96 h | Americamysis bahia | Static system | Salt water | Experimental value | | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Toxicity algae and other aquatic plants | EC50 | OECD 201 | 19000 mg/l | 96 h | Pseudokirchneriella subcapitata | Static system | Fresh water | Experimental value | | | EC50 | OECD 201 | 19100 mg/l | 96 h | Skeletonema costatum | Static system | Salt water | Experimental value | | Long-term toxicity fish | ChV | ECOSAR | 2500 mg/l | 30 day(s) | | | Fresh water | QSAR | | Long-term toxicity aquatic crustacea | NOEC | EPA 600/4-89/001 | 13020 mg/l | 7 day(s) | Ceriodaphnia sp. | Semi-static system | Fresh water | Experimental value | | Toxicity aquatic micro-organisms | NOEC | | 20000 mg/l | 18 day(s) | Pseudomonas putida | | Fresh water | Experimental value | | Toxicity sediment organisms | LC50 | | 6983 mg/kg sediment dw | 10 day(s) | Corophium volutator | Static system | Salt water | Experimental value |

12.1. Toxicity

12.1. Toxicity | | Parameter | Method | Value | Duration | Species | Test design | Fresh/salt water | Value determination | | --- | --- | --- | --- | --- | --- | --- | --- | --- | | Acute toxicity fishes | LC50 | | 40613 mg/l | 96 h | Oncorhynchus mykiss | Static system | Fresh water | Experimental value | | Acute toxicity crustacea | LC50 | EPA 600/4-90/027 | 18340 mg/l | 48 h | Ceriodaphnia dubia | Static system | Fresh water | Experimental value | | | LC50 | FIFRA 72-3 | 18800 mg/l | 96 h | Americamysis bahia | Static system | Salt water | Experimental value | | Toxicity algae and other aquatic plants | EC50 | OECD 201 | 19000 mg/l | 96 h | Pseudokirchneriella subcapitata | Static system | Fresh water | Experimental value | | | EC50 | OECD 201 | 19100 mg/l | 96 h | Skeletonema costatum | Static system | Salt water | Experimental value | | Long-term toxicity fish | ChV | ECOSAR | 2500 mg/l | 30 day(s) | | | Fresh water | QSAR | | Long-term toxicity aquatic crustacea | NOEC | EPA 600/4-89/001 | 13020 mg/l | 7 day(s) | Ceriodaphnia sp. | Semi-static system | Fresh water | Experimental value | | Toxicity aquatic micro-organisms | NOEC | | 20000 mg/l | 18 day(s) | Pseudomonas putida | | Fresh water | Experimental value | | Toxicity sediment organisms | LC50 | | 6983 mg/kg sediment dw | 10 day(s) | Corophium volutator | Static system | Salt water | Experimental value |

12.2. Persistence and degradability

MPG USP ### Biodegradation water

12.2. Persistence and degradability

### Biodegradation water | Method | Value | Duration | Value determination | | --- | --- | --- | --- | | OECD 301F: Manometric Respirometry Test | 81.7 % | 28 day(s) | Experimental value |

12.1 Toxicity

Not specified.

12.2. Persistence and degradability

Phototransformation air (DT50 air) | Method | Value | Conc. OH-radicals | Value determination | | --- | --- | --- | --- | | AOPWIN v1.92 | 0.834 day(s) | 1500000 /cm³ | QSAR |

12.3 Bioaccumulative potential

Not specified.

12.4 Mobility in soil

Not specified.

12.5 Results of PBT and vPvB assessment

Not specified.

12.6 Endocrine disrupting properties

Not specified.

12.7 Other adverse effects

Not specified.

12.2. Persistence and degradability

Phototransformation water (DT50 water) | Method | Value | Conc. OH-radicals | Value determination | | --- | --- | --- | --- | | | 2.3 year(s) | | Calculated value |

12.2. Persistence and degradability

### Biodegradation soil | Method | Value | Duration | Value determination | | --- | --- | --- | --- | | | 98 % | 105 day(s) | Experimental value |

12.2. Persistence and degradability

Biodegradation water | Method | Value | Duration | Value determination | | --- | --- | --- | --- | | OECD 301F: Manometric Respirometry Test | 81.7 % | 28 day(s) | Experimental value |

12.2. Persistence and degradability

Phototransformation air (DT50 air) | Method | Value | Conc. OH-radicals | Value determination | | --- | --- | --- | --- | | AOPWIN v1.92 | 0.834 day(s) | 1500000 /cm³ | QSAR |

12.2. Persistence and degradability

### Phototransformation water (DT50 water) | Method | Value | Conc. OH-radicals | Value determination | | --- | --- | --- | --- | | | 2.3 year(s) | | Calculated value |

12.2. Persistence and degradability

### Biodegradation soil | Method | Value | Duration | Value determination | | --- | --- | --- | --- | | | 98 % | 105 day(s) | Experimental value |

12.2 Persistence and degradability

Readily biodegradable in water Photodegradation in water occurs slowly Biodegradable in the soil under anaerobic conditions

12.3. Bioaccumulative potential

BCF fishes

12.3. Bioaccumulative potential

BCF fishes | Parameter | Method | Value | Duration | Species | Value determination | | --- | --- | --- | --- | --- | --- | | BCF | | 0.09 | | | Calculated value |

12.3. Bioaccumulative potential

Log Kow | Method | Remark | Value | Temperature | Value determination | | --- | --- | --- | --- | --- | | Equivalent to OECD 107 | | -1.07 | 20.5 °C | Test data |

12.3. Bioaccumulative potential

BCF fishes | Parameter | Method | Value | Duration | Species | Value determination | | --- | --- | --- | --- | --- | --- | | BCF | | 0.09 | | | Calculated value |

12.3. Bioaccumulative potential

Log Kow | Method | Remark | Value | Temperature | Value determination | | --- | --- | --- | --- | --- | | Equivalent to OECD 107 | | -1.07 | 20.5 °C | Test data |

12.4. Mobility in soil

### MPG USP Volatility (Henry's Law constant H) | Value | Method | Temperature | Remark | Value determination | | --- | --- | --- | --- | --- | | 0.00566 atm m³/mol | EUSES calculation | 12 °C | | Estimated value | Percent distribution | Method | Fraction air | Fraction biota | Fraction sediment | Fraction soil | Fraction water | Value determination | | --- | --- | --- | --- | --- | --- | --- | | Mackay level III | 2.98 % | | 0.07 % | 48.1 % | 48.8 % | Calculated value | propane-1,2-diol Volatility (Henry's Law constant H) | Value | Method | Temperature | Remark | Value determination | | --- | --- | --- | --- | --- | | 0.00566 atm m³/mol | EUSES calculation | 12 °C | | Estimated value | Percent distribution | Method | Fraction air | Fraction biota | Fraction sediment | Fraction soil | Fraction water | Value determination | | --- | --- | --- | --- | --- | --- | --- | | Mackay level III | 2.98 % | | 0.07 % | 48.1 % | 48.8 % | Calculated value |

12.5. Results of PBT and vPvB assessment

Substance does not meet the criteria of PBT, nor the criteria of vPvB according to Annex XIII of Regulation (EC) No 1907/2006, so is neither PBT nor vPvB.

12.6. Other adverse effects

MPG USP Fluorinated greenhouse gases (Regulation (EU) No 517/2014) Not included in the list of fluorinated greenhouse gases (Regulation (EU) No 517/2014) Ozone-depleting potential (ODP) Not classified as dangerous for the ozone layer (Regulation (EC) No 1005/2009) Groundwater Groundwater pollutant propane-1,2-diol Groundwater Groundwater pollutant

The substance is not a fluorinated greenhouse gas and is not classified as dangerous for the ozone layer. It is identified as a groundwater pollutant.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Remove to an authorized waste incinerator for solvents with energy recovery.

Disposal

Remove waste in accordance with local and/or national regulations.

Waste Codes

07 01 99 wastes from the manufacture, formulation, supply and use (MFSU) of basic organic chemicals: wastes not otherwise specified EWC
15 01 04 metallic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is MPG USP known by?

MPG USP is also known as: 1,2-propanediol; alpha-propylene glycol; monopropylene glycol; propane-1,2-diol

What is the hazard signal word for MPG USP?

The signal word is no signal word.

What is the physical form of MPG USP?

MPG USP is a liquid appearing as colourless with colourless color. It has almost odourless odor.

What is the solubility of MPG USP?

Water ; complete; Ethanol ; complete; Acetone ; complete; Ether ; 12 g/100 ml

What is MPG USP used for?

Manufacture of substance Distribution of substance Formulation & (re)packing of substances and mixtures Use in coatings Use in coatings Use in coatings Use in Cleaning Agents Use in Cleaning Agents Use in Cleaning Agents Functional Fluids Functional Fluids Functional Fluids Use in/as de-icing/anti-icing applications/agents Use in/as de-icing/anti-icing applications/agents Other Consumer Uses Use in laboratories Use in laboratories Mining chemicals Use as binders and release agents Use as binders and release agents Water treatment Water treatment Water treatment Production of polymers Rubber production and processing Use of fuel Use of fuel Agrochemical uses Agrochemical uses Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use

What is the melting point of MPG USP?

The melting point is < -20 °C ; Test data and the boiling point is 184 °C ; 1003.2 hPa ; Test data.