Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MPG USP
- Product Code
- 61510
- Synonyms
- 1,2-propanediol; alpha-propylene glycol; monopropylene glycol; propane-1,2-diol
Regulatory Identifiers
- CAS Number
- 57-55-6 Check regulations →
- EC Number
- 200-338-0 Check regulations →
- REACH No.
- 01-2119456809-23-0006
Identified Uses
Manufacture of substance Distribution of substance Formulation & (re)packing of substances and mixtures Use in coatings Use in coatings Use in coatings Use in Cleaning Agents Use in Cleaning Agents Use in Cleaning Agents Functional Fluids Functional Fluids Functional Fluids Use in/as de-icing/anti-icing applications/agents Use in/as de-icing/anti-icing applications/agents Other Consumer Uses Use in laboratories Use in laboratories Mining chemicals Use as binders and release agents Use as binders and release agents Water treatment Water treatment Water treatment Production of polymers Rubber production and processing Use of fuel Use of fuel Agrochemical uses Agrochemical uses Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use
Uses advised against
No uses advised against known
Manufacturers & Suppliers
INEOS N.V.
global supplier
Haven 1053 - Nieuwe Weg 1, B-2070 Zwijndrecht
+32 3 250 91 11
INEOS Manufacturing Deutschland GmbH
manufacturer
Alte Strasse 201, D-50769 Köln
+49 221 35 55 22 22
Emergency Contacts
BIG
+32 14 58 45 45
24h/24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propane-1,2-diol EC: 200-338-0 | 57-55-6 | 99% | No |
Notes
(2) Substance with a Community workplace exposure limit
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Symptoms: EXPOSURE TO HIGH CONCENTRATIONS: Dry/sore throat.
Rinse with water. Do not apply (chemical) neutralizing agents without medical advice. Take victim to a doctor if irritation persists.
Symptoms: Slight irritation. ON CONTINUOUS EXPOSURE/CONTACT: Red skin. Dry skin.
Rinse with water. Remove contact lenses, if present and easy to do. Continue rinsing. Do not apply (chemical) neutralizing agents without medical advice. Take victim to an ophthalmologist if irritation persists.
Symptoms: Redness of the eye tissue. Slight irritation.
Rinse mouth with water. Do not apply (chemical) neutralizing agents without medical advice. Consult a doctor/medical service if you feel unwell.
Symptoms: AFTER INGESTION OF HIGH QUANTITIES: Cramps/uncontrolled muscular contractions. Nausea. Abdominal pain.
Immediate Medical Attention
Depending on the victim's condition: doctor/hospital. Respiratory problems: consult a doctor/medical service. Take victim to a doctor if irritation persists. Take victim to an ophthalmologist if irritation persists. Consult a doctor/medical service if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Small fire: Quick-acting ABC powder extinguisher, Quick-acting BC powder extinguisher, Quick-acting class B foam extinguisher, Quick-acting CO2 extinguisher. Major fire: Class B foam (alcohol-resistant), Water spray if puddle cannot expand.
Small fire: Water (quick-acting extinguisher, reel); risk of puddle expansion. Major fire: Water; risk of puddle expansion.
Upon combustion: CO and CO2 are formed.
Cool tanks/drums with water spray/remove them into safety.
Firefighter Protection
Gloves. Protective clothing. Heat/fire exposure: compressed air/oxygen apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contain released product, pump into suitable containers. Plug the leak, cut off the supply.
Scoop absorbed substance into closing containers. Clean contaminated surfaces with an excess of water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Gas/vapour heavier than air at 20°C. Observe normal hygiene standards. Keep container tightly closed.
Keep container tightly closed.
Observe normal hygiene standards.
Keep away from naked flames/heat. Finely divided: keep away from ignition sources/sparks.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Measure the concentration in the air regularly. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.
Protective gloves against chemicals (EN374). - materials (good resistance) Nitrile rubber, butyl rubber, natural rubber, polyethylene, PVC, polyethylene/ethylenevinylalcohol.
Safety glasses.
Respiratory protection not required in normal conditions.
Protective clothing.
See headings 6.2, 6.3 and 13
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
Temperature above flashpoint: higher fire/explosion hazard.
Reacts violently with (strong) oxidizers: (increased) risk of fire. Violent to explosive reaction with (strong) acids.
Keep away from naked flames/heat. At temperature > flashpoint: use spark-/explosionproof appliances. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks.
Oxidizing agents, reducing agents, (strong) acids, water/moisture.
Upon combustion: CO and CO2 are formed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
12.1 Toxicity
12.2. Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2 Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
The substance is not a fluorinated greenhouse gas and is not classified as dangerous for the ozone layer. It is identified as a groundwater pollutant.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Remove to an authorized waste incinerator for solvents with energy recovery.
Remove waste in accordance with local and/or national regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is MPG USP known by?
MPG USP is also known as: 1,2-propanediol; alpha-propylene glycol; monopropylene glycol; propane-1,2-diol
What is the hazard signal word for MPG USP?
The signal word is no signal word.
What is the physical form of MPG USP?
MPG USP is a liquid appearing as colourless with colourless color. It has almost odourless odor.
What is the solubility of MPG USP?
Water ; complete; Ethanol ; complete; Acetone ; complete; Ether ; 12 g/100 ml
What is MPG USP used for?
Manufacture of substance Distribution of substance Formulation & (re)packing of substances and mixtures Use in coatings Use in coatings Use in coatings Use in Cleaning Agents Use in Cleaning Agents Use in Cleaning Agents Functional Fluids Functional Fluids Functional Fluids Use in/as de-icing/anti-icing applications/agents Use in/as de-icing/anti-icing applications/agents Other Consumer Uses Use in laboratories Use in laboratories Mining chemicals Use as binders and release agents Use as binders and release agents Water treatment Water treatment Water treatment Production of polymers Rubber production and processing Use of fuel Use of fuel Agrochemical uses Agrochemical uses Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use Use in oilfield chemicals - marine and offshore Use in oilfield chemicals - onshore use
What is the melting point of MPG USP?
The melting point is < -20 °C ; Test data and the boiling point is 184 °C ; 1003.2 hPa ; Test data.