Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC 4666 Fuel Additive
- Product Code
- H4666
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Petrochemical industry: Fuel additive.
Manufacturers & Suppliers
Afton Chemical Corporation
manufacturer
500 Spring St. Richmond, VA 23219
+1-804-788-5800
Afton Chemical Japan Corporation
manufacturer
Sumitomo Fudousan Sanbancho Bldg. 5F 6-26 Sanbancho, Chiyoda-ku Tokyo 102-0075 Japan
+81-3-5210-4890
Afton Chemical Limited
manufacturer
Euro-Tech Centre London Road, Bracknell, Berkshire RG12 2UW, England
+44 1344-304141
Afton Chemical Asia Pacific Company
manufacturer
Level 9, 20 Berry Street North Sydney, NSW 2060 Australia
+02-9923-1588
Emergency Contacts
Emergency Contact
+1-800-403-0044
Emergency Contact
+1-804-648-7727
Emergency Contact
+32-2-507-20-64
Emergency Contact
+81-3-5210-4890
Afton Chemical Japan Corporation
+81-3-5210-4890
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS06
GHS08
GHS09
Hazard Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-Ethylhexyl nitrate | 27247-96-7 | 60 - 100% | Yes |
| Solvent naphtha (petroleum), heavy aromatic | 64742-94-5 | 1 - 4.9% | Yes |
| 2-Ethyl hexanol | 104-76-7 | 1 - 4.9% | Yes |
| Benzene, 1,2,4-trimethyl- | 95-63-6 | 0.1 - 0.5% | Yes |
| Naphthalene | 91-20-3 | 0.1 - 0.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention immediately.
In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Get medical attention immediately.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention immediately.
Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. If affected person is fully conscious, give one glass of water to drink. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get medical attention immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO2.
COMBUSTIBLE. - United States and Canada. VAPOR MAY CAUSE FLASH FIRE. Vapors may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Runoff to sewer may create fire or explosion hazard. When heated above 100°C/212°F may undergo a self-accelerating, exothermic reaction which causes a rapid rise in temperature and pressure. Rupture of storage vessels and fire should be anticipated in case of such temperature.
Spray storage vessels with water to maintain temperature below 100°C/212°F.
Firefighter Protection
Fire-fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Immediately contact emergency personnel. Eliminate all ignition sources. Keep unnecessary personnel away. Use suitable protective equipment (section 8). Follow all fire-fighting procedures (section 5). Do not touch or walk through spilled material.
For small spills, add absorbent (soil may be used in the absence of other suitable materials) and use a non-sparking or explosion-proof means to transfer material to a sealable, appropriate container for disposal.
For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway. Place spilled material in an appropriate container for disposal.
Avoid contact of spilled material with soil and prevent runoff entering surface waterways.
use a non-sparking or explosion-proof means to transfer material to a sealable, appropriate container for disposal.
Materials: absorbent (soil may be used in the absence of other suitable materials)
Related Products
Similar products with comparable safety profiles
HiTEC 4679 Fuel Additive
---
HiTEC® 4682 Fuel Additive
UFI: DUW8-H8FF-TM6Y-D36R
HiTEC® 47600 Fuel Additive
UFI: K10T-107H-6005-37W7
HiTEC® 46014 Fuel Additive
UFI: 1UUM-JX47-H68J-MESM
HiTEC® 47004 Fuel Additive
UFI: SMTS-40RG-V00Y-ER65
HiTEC® 47004 Fuel Additive
UFI: SMTS-40RG-V00Y-ER65
HiTEC® 47004 Fuel Additive
UFI: SMTS-40RG-V00Y-ER65
HiTEC® 46000 Fuel Additive
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and breathing vapor or mist. Keep away from heat, sparks and flame. Wash thoroughly after handling. Keep container closed.
Wash thoroughly after handling.
Keep away from heat, sparks and flame. To avoid fire or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before transferring material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Unstable at temperatures greater than 100°C/212°F.
High temperatures, sparks, and open flames.
Strong oxidizing and reducing agents.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Harmful to aquatic organisms with potential long-term effects.
12.2 Persistence and degradability
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste must be disposed of in accordance with federal, state and local environmental control regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (2-ethylhexyl nitrate)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
EU: Harmful. Risk phrases: R44, R20/21, R52/53. Safety phrases: S15, S23, S36/37/39, S61. Contains: 2-Ethylhexyl nitrate.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC 4666 Fuel Additive?
The signal word is warning.
What is the physical form of HiTEC 4666 Fuel Additive?
HiTEC 4666 Fuel Additive is a liquid appearing as clear. brown. with clear. brown. color. It has characteristic. odor.
What is HiTEC 4666 Fuel Additive used for?
Petrochemical industry: Fuel additive.
What are the hazard statements for HiTEC 4666 Fuel Additive?
This substance has 7 hazard statements:
- EUH066: VAPOR MAY CAUSE FLASH FIRE.
- EUH206: COMBUSTIBLE.
- H304: ASPIRATION HAZARD IF SWALLOWED.
- H311: HARMFUL IF ABSORBED THROUGH SKIN OR IF INHALED.
- H335: CAUSES RESPIRATORY TRACT, EYE AND SKIN IRRITATION.
- H402: Harmful to aquatic organisms.
- H411: May cause long-term adverse effects in the aquatic environment.