Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Q8 Formula Exclusive C3 5W-30
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricating oil for automotive engines
Manufacturers & Suppliers
Kuwait Petroleum Companies in the Benelux
national supplier
Brusselstraat 59, 2018 Antwerp, Belgium
+32 3 247 38 11
Kuwait Petroleum Belgium N.V./S.A.
manufacturer
Petroleumkaai 7, B-2020 Antwerp, Belgium
Q8Oils Italia S.r.l.
manufacturer
Via Volpedo 2, 15050 Castellar Guidobono (AL), Italy
Emergency Contacts
CARECHEM24
+44 (0) 1235 239 670
CARECHEM24
+44 (0) 1865 407 333
EN
Poisons Information Centre
+43 1 406 43 43
Poison Centre
+32 (0)70 245 245
National Toxicology Centre
+359 (0)2 9154 233
Poison Control Centre
+385 (0)1 23-48-342
Poison Centre
1401
Toxicological Information Centre
+420 224 919 293
Toxicological Information Centre
+420 224 915 402
Bispebjerg Hospital - poison line
+45 8212 1212
Emergency Contact
112
Poison Information Centre, Health Board
16662
Poison Information Centre, Health Board
+372 7943 794
Emergency Contact
112
Poison Information Center
+358 (0)9 471 977
Poison Control Centre (ORFILA)
+33 (0)1 45 42 59 59
Emergency Poison Centre telephone number, Aglaia Kyriakou Children's Hospital
+30 210 779 3777
Health Toxicological Information Service
+36 (06) 80 201-199
Poison Information Centre
+354 543 2222
NPIC Beaumont Hospital
+353 (0)1 809 2166
8am-10pm, 7 days a week
CAV "Osp. Pediatrico Bambino Gesù" Dip. Emergenza e Accettazione DEA (ROMA)
06 68593726
Az. Osp. Univ. Foggia (FOGGIA)
800183459
Az. Osp. "A. Cardarelli" (NAPOLI)
081-5453333
CAV Policlinico "Umberto I" (ROMA)
06-49978000
CAV Policlinico "A. Gemelli" (ROMA)
06-3054343
Az. Osp. "Careggi" U.O. Tossicologia Medica (FIRENZE)
055-7947819
CAV Centro Nazionale di Informazione Tossicologica (PAVIA)
0382-24444
Osp. Niguarda Ca' Granda (MILANO)
02-66101029
Azienda Ospedaliera Papa Giovanni XXII (BERGAMO)
800883300
Azienda Ospedaliera Integrata Verona (VERONA)
800011858
Emergency Contact
112
State Toxicology Center, Poisoning and Drug Information Center
+371 67042473
Tox InfoSuisse
145
Tox InfoSuisse
+41 44 251 51 51
Emergency Contact
112
Poison Information Office
+370 (8)5 236 20 52
Poison Information Office
+370 (8)6 875 33 78
Belgian Poison Centre
8002 5500
Emergency Contact
112
Poison Centre
+356 2545 6504
Nationaal Vergiftigingen Informatie Centrum
+31 (0)88 755 8000
Poison Centre
+47 22 59 13 00
Poison Information Centre
+351 800 250 250
National Institute of Public Health
+40 (0)21 318 36 06
08:00 - 15:00
National Toxicological Information Centre
+421 (0)2 54 774 166
Emergency Contact
112
Toxicological Information Service
+34 91 562 04 20
Emergency Contact
112
Tox Info Suisse
145
Tox Info Suisse
+41 44 251 51 51
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Severely refined mineral oil (C15 - C50) | --- | 75 - 90% | No |
| Severely refined mineral oil (C15 - C50) | --- | 10 - 25% | Yes |
| Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 | 68784-26-9 | 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Adverse symptoms may include the following: irritation, dryness, cracking
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Immediate Medical Attention
Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, alcohol-resistant foam or water spray (fog).
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist.
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant or proceed as follows.
Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8).
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Wear suitable gloves tested to EN374. Recommended: < 1 hour (breakthrough time): nitrile rubber 0.17 mm. Provide employee with skin care programmes.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: Boiling point > 65 °C: A1; Boiling point < 65 °C: AX1; Hot material: A1P2.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
No specific data.
Strong oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
Not available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The mixture does not contain any substances that are assessed to be a PBT or a vPvB.
12.6 Endocrine disrupting properties
Not available.
12.7 Other adverse effects
No known significant effects or critical hazards.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulatory information for Q8 Formula Exclusive C3 5W-30
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Q8 Formula Exclusive C3 5W-30?
The signal word is no signal word.
What is the physical form of Q8 Formula Exclusive C3 5W-30?
Q8 Formula Exclusive C3 5W-30 is a liquid. [oily liquid.] appearing as clear. with brown. [light] color. It has not available. odor.
What is Q8 Formula Exclusive C3 5W-30 used for?
Lubricating oil for automotive engines
What are the hazard statements for Q8 Formula Exclusive C3 5W-30?
This substance has 1 hazard statement:
- No known significant effects or critical hazards.
What is the melting point of Q8 Formula Exclusive C3 5W-30?
The melting point is Not applicable. and the boiling point is >200°C (>392°F).