Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Appretan N9616 liq RT
- Product Code
- 124644
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Textile processing industry Textile finish
Manufacturers & Suppliers
Archroma Distrib.&Mgt. GmbH, Sede sec.IT
distributor
Via Gabriele D'Annunzio 2 – 21010 Vizzola Ticino (VA).
+39 031 8123180
Emergency Contacts
Emergency Contact
+33 1 7211 0003
NCEC (EU)
+44 1235 239670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 5-Chloro-2-methyl-2,3-dihydroisothiazol-3-one and 2-Methyl-2,3-dihydroisothiazol-3-one (3:1) EC: 911-418-6 | 55965-84-9 | 0.0002 - 0.0015% | Yes |
| Formaldehyde EC: 200-001-8 | 50-00-0 | 0.02 - 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. Get medical advice/ attention.
If on skin, rinse well with water.
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Call in a physician immediately and show him the Safety Data Sheet.
Immediate Medical Attention
Get medical advice/ attention for inhalation, seek medical advice for eye contact, and call in a physician immediately for ingestion.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray jet, Alcohol-resistant foam, Dry powder, Carbon dioxide (CO2)
High volume water jet
In case of fire hazardous decomposition products may be produced such as: Carbon monoxide and carbon dioxide
Firefighter Protection
Self-contained breathing apparatus, Full protective suit
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. The product should not be allowed to enter drains, water courses or the soil.
Soak up with inert absorbent material
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. It cannot be ruled out, that traces of following substances are present. Formaldehyde
Protect against frost. The product after freezing is no longer usable. Protect from extreme heat and cold.
Wash hands before breaks and at the end of workday. Use protective skin cream before handling the product. Take off immediately all contaminated clothing and wash it before reuse. Do not eat, drink or smoke when using this product. Observe the usual precautions for handling chemicals.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Local ventilation recommended - mechanical ventilation may be used.
Nitrile rubber gloves. These types of protective gloves are offered by various manufacturers. Please note the manufacturers' detailed statements, especially about the minimum thickness and the minimum breakthrough time. Consider also the particular working conditions under which the gloves are being used.
Safety glasses. see respiratory protection
Use respiratory protection in case of insufficient exhaust ventilation or prolonged exposure. Filter A (organic gases and vapours) to standard DIN EN 141
Wear suitable protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
See section 10.3. "Possibility of hazardous reactions"
No dangerous reaction known under conditions of normal use.
freezing
not known
No hazardous decomposition products if stored and handled as prescribed
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
12.3. Bioaccumulative potential
No information is available on the mixture as is.
12.3. Bioaccumulative potential
Method : OECD Guide-line 305 E
12.3. Bioaccumulative potential
12.4. Mobility in soil
Koc : 7,7
Method : OECD Test Guideline 106 Information related to the component: Formaldehyde Transport and distribution between environmental compartments: adsorption (Soil)
Koc : 15,9
log Koc : 1,202
12.5. Results of PBT and vPvB assessment
The mixture is not assessed as a whole. The components 5-Chloro-2-methyl-2,3-dihydroisothiazol-3-one and 2-Methyl-2,3-dihydroisothiazol-3-one (3:1) and Formaldehyde are not identified as PBT or vPvB substances.
12.6. Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.
12.7. Other adverse effects
Avoid release to the environment.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Appretan N9616 liq RT?
The signal word is no signal word.
What is the physical form of Appretan N9616 liq RT?
Appretan N9616 liq RT is a liquid with milky white color. It has slight, of acrylate odor.
What is Appretan N9616 liq RT used for?
Textile processing industry Textile finish