Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIA 6114
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial use wide dispersive use
Uses advised against
No additional information available
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2, 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
Emergency Contact
+32 3 575 55 55
24/7
Emergency Contact
+1 888 765 6554
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| SDS from supplier (purchased material; Refined Linseed oil) EC: 232-278-6 | 8001-26-1 | 80% | No |
| Fatty acids, tall-oil EC: 263-107-3 | 61790-12-3 | 20% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.
Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.
Symptoms: Slight irritation.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Symptoms: AFTER INGESTION OF HIGH QUANTITIES: Diarrhoea.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.
Solid water jet ineffective as extinguishing medium.
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard.
Cool tanks/drums with water spray/remove them into safety.
Firefighter Protection
Heat/fire exposure: compressed air/oxygen apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes. No naked flames.
Prevent soil and water pollution.
Clean contaminated surfaces with an excess of water and soap solution. Take up liquid spill into inert absorbent material.
Materials: dry sand/earth/vermiculite or powdered limestone
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from naked flames/heat. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Carry operations in the open/under local exhaust/ventilation or with respiratory protection. Comply with the legal requirements. Remove contaminated clothing immediately. Clean contaminated clothing. Thoroughly clean/dry the installation before use. Do not discharge the waste into the drain. Keep container tightly closed.
Keep container tightly closed.
Remove contaminated clothing immediately. Clean contaminated clothing.
Keep away from naked flames/heat. Finely divided: keep away from ignition sources/sparks.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves (nitrile rubber)
Safety glasses
Respiratory protection not required in normal conditions
Protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
Biodegradability in water: no data available.
12.3. Bioaccumulative potential
Not bioaccumulative.
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling
Remove waste in accordance with local and/or national regulations. Remove to an authorized incinerator equipped with an afterburner and a flue gas scrubber with energy recovery. Dissolve or mix with a combustible solvent.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Compliant with AICS, DSL, ECST, IECSC, INSQ, KECL, NZIoC, PICCS, TSCA, EC inventories.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIA 6114?
The signal word is no signal word.
What is the physical form of RADIA 6114?
RADIA 6114 is a liquid appearing as liquid. with light yellow or yellow-brown. on exposure to air: turns dark. color. It has characteristic odour. sweet odour. odor.
What is the solubility of RADIA 6114?
Insoluble in water. Soluble in ether. Soluble in other organic solvents.
What is RADIA 6114 used for?
Industrial use wide dispersive use
What is the melting point of RADIA 6114?
The melting point is ca. -15 °C and the boiling point is > 150 °C.