Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIA 7112
- Product Form
- Substance (UVCB)
- Chemical Name
- Fatty acids, C10-16 (even numbered), Me esters
Regulatory Identifiers
- CAS Number
- 67762-40-7 Check regulations →
- EC Number
- 267-018-0 Check regulations →
- REACH No.
- 05-2114544859-31-0000
Identified Uses
Industrial use
Uses advised against
No additional information available
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2, 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
SGS ERS
+32 3 575 55 55
SGS ERS
+1 888 765 6554
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty acids, C10-16, Me esters EC: 267-018-0 | 67762-40-7 | --- | No |
| Methyl laurate EC: 203-911-3 | 111-82-0 | 50 - 80% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.
Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.
Solid water jet ineffective as extinguishing medium.
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes. No naked flames.
Prevent soil and water pollution.
Clean contaminated surfaces with an excess of water and soap solution. Take up liquid spill into inert absorbent material.
Materials: dry sand/earth/vermiculite or powdered limestone.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handling temperature: ≥ 10 °C above melting point
Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.
KEEP SUBSTANCE AWAY FROM: ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber
Safety glasses.
Protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The substance is classified as very toxic to aquatic life with long-lasting effects.
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling
Remove to an authorized waste treatment plant.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Methyl laurate)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIA 7112?
The signal word is warning.
What is the physical form of RADIA 7112?
RADIA 7112 is a liquid appearing as liquid. with yellow to amber. color. It has characteristic odour. mild odour. odor.
What is the solubility of RADIA 7112?
Water: ca. 7,8 mg/l (25°C)
What is RADIA 7112 used for?
Industrial use
What are the hazard statements for RADIA 7112?
This substance has 1 hazard statement:
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of RADIA 7112?