Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 33630 Performance Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical S.R.L. (Feluy Plant)
manufacturer
Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Emergency Contacts
Emergency Contact
+43-13649237
Emergency Contact
+351-308801773
Emergency Contact
+32-28083237
Emergency Contact
+421-233057972
Emergency Contact
+359-32570104
Emergency Contact
+38-618888016
Emergency Contact
+385-17776920
Emergency Contact
+46-852503403
Emergency Contact
+420-228880039
Emergency Contact
+41-435082011
Emergency Contact
+45-69918573
Emergency Contact
+380-947101374
Emergency Contact
+358-942419014
Emergency Contact
+44-8708200418
Emergency Contact
+33-975181407
Emergency Contact
+1-703-527-3887
Emergency Contact
+49-69-6435-08409
Emergency Contact
+65-3158-1349
Emergency Contact
+36-18088425
Emergency Contact
+61-290372994
Emergency Contact
+353-19014670
Emergency Contact
4001-204937
Emergency Contact
+39-0245557031
Emergency Contact
+(91)-22-3354 3594
Emergency Contact
+352-20202416
Emergency Contact
+81-345209637
Emergency Contact
+31-858880596
Emergency Contact
00-308-13-2549
Emergency Contact
+47-21930678
Emergency Contact
+1-703-741-5979
Emergency Contact
+48-223988029
Emergency Contact
1-800-424-9300
Emergency Contact
+43 1 406 43 43
Emergency Contact
+32 (0)70 245 245
Emergency Contact
+359 2 9154 233
Emergency Contact
+3851 2348 342
Emergency Contact
+357 1401
Emergency Contact
+420 224 91 92 93
Emergency Contact
+45 8212 1212
Emergency Contact
+372 16662
Emergency Contact
+33 (0)1 45 42 59 59
Emergency Contact
+30 210 779 3777
Emergency Contact
+36 80 201 199
Emergency Contact
+371 67042473
Emergency Contact
+370 (85) 236 2052
Emergency Contact
+352 8002 5500
Emergency Contact
+31 (0)88 755 8000
Emergency Contact
+47 22 59 13 00
Emergency Contact
+351 800 250 250
Emergency Contact
+40 (0)21 318 36 06
8am – 3pm
Emergency Contact
+421 2 5477 4166
Emergency Contact
+386 112
Emergency Contact
+34 91 562 04 20
Emergency Contact
+354 112
Emergency Contact
+46 112
Emergency Contact
+39 800 883 300
Emergency Contact
+39 055 794 7819
Emergency Contact
+39 800 183 459
Emergency Contact
+39 02 6610 1029
Emergency Contact
+39 081 545 3333
Emergency Contact
+39 0382 24444
Emergency Contact
+39 06 305 4343
Emergency Contact
+39 06 4997 8000
Emergency Contact
+39 06 6859 3726
Emergency Contact
+39 800 011 858
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polysulfides, di-tert-Bu EC: 273-103-3 | 68937-96-2 | 25 - 35% | Yes |
| Polysulfides, di-tert-Bu EC: 273-103-3 | 68937-96-2 | 15 - 25% | Yes |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 5 - 10% | No |
| Distillates (petroleum), solvent-refined heavy paraffinic EC: 265-090-8 | 64741-88-4 | 5 - 10% | No |
| Reaction products of bis(4-methylpentan-2-yl) dithiophosphoric acid with phosphorus oxide, propylene oxide and amines, C12-14-alkyl (branched) EC: 931-384-6 | 141904-03-2 | 3 - 5% | Yes |
| 1,3,4-Thiadiazolidine-2,5-dithione, reaction products with hydrogen peroxide and tert-nonanethiol EC: 293-927-7 | 89347-09-1 | 1 - 3% | Yes |
| N-methyl-N-[C18-(unsaturated)alkanoyl]glycine EC: 701-177-3 | --- | 0.1 - 0.3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.
Symptoms: In case of inhalation of decomposition products in a fire, symptoms may be delayed.
Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Get medical attention. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse. Continue to rinse for at least 15 minutes.
Symptoms: May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness.
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.
Symptoms: No known significant effects or critical hazards. No specific data.
Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: No known significant effects or critical hazards. No specific data.
Immediate Medical Attention
Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO₂.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst. This material is harmful to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.
Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 336 Performance Additive
UFI: 1GS9-20KJ-W006-S92D
HiTEC® 33880 Performance Additive
UFI: MTV9-K0JW-0877-7HT0
HiTEC® 34022 Performance Additive
UFI: 1D6P-M0MN-K005-UJJU
HiTEC® 3301 Performance Additive
UFI: MAQJ-VQGV-6N2N-PH6R
HiTEC® 340 Performance Additive
UFI: FFRA-A9AQ-HT21-VCP5
HiTEC® 340 Performance Additive
UFI: FFRA-A9AQ-HT21-VCP5
HiTEC® 33321 Performance Additive
UFI: GKUN-U0NM-Y00T-GJ4Q
HiTEC® 339 Performance Additive
UFI: GUX9-Q8KS-P750-D94Q
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Hydrogen sulfide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
Not available.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The mixture does not contain any substances that are assessed to be a PBT or a vPvB.
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2020/878 and United Kingdom
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 33630 Performance Additive?
The signal word is warning.
What is the physical form of HiTEC® 33630 Performance Additive?
HiTEC® 33630 Performance Additive is a liquid. appearing as liquid. [clear.] with amber. color. It has not available. odor.
What is the solubility of HiTEC® 33630 Performance Additive?
Not available.
What is HiTEC® 33630 Performance Additive used for?
Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional
What are the hazard statements for HiTEC® 33630 Performance Additive?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of HiTEC® 33630 Performance Additive?
The melting point is Not available. and the boiling point is Not available..