Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIAMULS LACTEM 2950K
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Fit for use in foodstuffs
Uses advised against
No additional information available
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
SGS ERS; Oleon contract nr 76858
+32 3 575 55 55
24/7
SGS ERS; Oleon contract nr 76858
+1 888 765 6554
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Rinse with water. Soap may be used. Take victim to a doctor if irritation persists.
Rinse with water. Take victim to an ophthalmologist if irritation persists.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Fire hazard : DIRECT FIRE HAZARD: Not easily combustible. In finely divided state: increased fire hazard. INDIRECT FIRE HAZARD: Temperature above flashpoint: higher fire/explosion hazard. Explosion hazard : DIRECT EXPLOSION HAZARD: Fine dust is explosive with air. INDIRECT EXPLOSION HAZARD: Dust cloud can be ignited by a spark.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Prevent dust cloud formation, e.g. by wetting. Dust production: have neighbourhood close doors and windows. Exposure to heat: have neighbourhood close doors and windows.
Related Products
Similar products with comparable safety profiles
RADIAMULS LACTEM 2951K
CAS: 1338-10-9
RADIAMULS LACTEM 2949K
CAS: 1338-10-9
RADIAMULS CITREM 2935K
CAS: 91052-20-9
RADIAMULS SL 2990K
CAS: 25383-99-7
RADIAMULS ACETEM 2050K
CAS: 93572-32-8
RADIAMULS SORB 2160K
---
RADIAMULS SL 2992K
CAS: 25383-99-7
RADIAMULS CITREM 2932K
CAS: 91744-38-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep substance away from: ignition sources, (strong) acids, (strong) bases.
Store at a temperature <18°C (above 18°C enhanced caking may occur). Store in a well-ventilated place.
Keep substance away from ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber
In case of dust production: protective goggles.
Dust production: dust mask with filter type P2.
Protective clothing. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
According to literature: no environmental hazard. The substance is not classified for acute or chronic aquatic toxicity.
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Scoop solid spill into closing containers, Powdered: do not use compressed air for pumping over spills, Clean contaminated surfaces with a soap solution
Remove to an authorized waste treatment plant.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No additional information available
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIAMULS LACTEM 2950K?
The signal word is no signal word.
What is the physical form of RADIAMULS LACTEM 2950K?
RADIAMULS LACTEM 2950K is a solid appearing as solid in various shapes. with white to light yellow. color. It has characteristic odour. almost odourless. odor.
What is the solubility of RADIAMULS LACTEM 2950K?
Soluble in oils/fats. soluble in most organic solvents. Insoluble in water.
What is RADIAMULS LACTEM 2950K used for?
Fit for use in foodstuffs
What is the melting point of RADIAMULS LACTEM 2950K?
The melting point is > 40 °C and the boiling point is > 250 °C.