NextSDS Logo
Safety Data Sheet EN

030PCXX

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
030PCXX
Product Code
A03936

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Engine oil

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'ile 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

Emergency Contacts

France - ORFILA (INRS)

+33 (0)1 45 42 59 59

ANGERS

02 41 48 21 21

BORDEAUX

05 56 96 40 80

LILLE

08 00 59 59 59

LYON

04 72 11 69 11

MARSEILLE

04 91 75 25 25

NANCY

03 83 22 50 50

PARIS

01 40 05 48 48

STRASBOURG

03 88 37 37 37

TOULOUSE

05 61 77 74 47

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 75 - 90% Yes
Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based EC: 276-738-4 72623-87-1 10% Yes
Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based EC: 276-737-9 72623-86-0 10% Yes
bis(nonylphenyl)amine EC: 253-249-4 36878-20-3 3% Yes
C14-16-18 Alkyl phenol EC: 931-468-2 --- 3% Yes

Mineral oil of petroleum origin Product containing mineral oil with less than 3% DMSO extract as measured by IP 346

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No specific data.

Skin contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: Adverse symptoms may include the following: irritation dryness cracking

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No specific data.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical,CO₂,water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material.

Materials: sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves, nitrile rubber, Fluorinated rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with EN 420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0,38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Respirator with combination filter for vapor/particulate Type A/P1 Warning ! filters have a limited use duration The use of breathing apparatus must comply strictly with the manufacturer's instructions and the regulations governing their choices and uses None under normal use conditions

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid. [limpid]
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Not available.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Open cup: 232°C [ISO 2592]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
0.842 [ASTM D 4052]
Bulk Density
---
Density
---
Flammability
Not available.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Insoluble in the following materials: cold water and hot water.
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C): 0.45 cm2/s [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

Strong oxidizing agents

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Product/substance: Distillates (petroleum), hydrotreated heavy paraffinic Acute EC50 >100 mg/l, Algae - Pseudokirchnerella subcapitata, 48 hours, OECD 201 Acute EC50 >10000 mg/l, Daphnia - Daphnia magna, 48 hours, OECD 202 Chronic NOEL 10 mg/l, Daphnia - Daphnia magna, 21 days Chronic NOEL >1000 mg/l, Fish - Oncorhynchus mykiss, 21 days

12.1 Toxicity

Product/substance: Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based Acute EC50 >100 mg/l, Algae - Pseudokirchnerella subcapitata, 48 hours, OECD 201 Acute EC50 >10000 mg/l, Daphnia - Daphnia magna, 48 hours, OECD 202 Acute LC50 >10000 mg/l, Daphnia - Gammarus pulex, 24 hours, OECD 202 Acute LC50 >10000 mg/l, Daphnia - Gammarus pulex, 48 hours, OECD 202 Acute LC50 >10000 mg/l, Daphnia - Gammarus pulex, 72 hours, OECD 202 Acute LC50 >10000 mg/l, Daphnia - Gammarus pulex, 96 hours, OECD 202 Acute NOEL 101 mg/l, Algae, 72 hours, OECD 201 Acute NOEL >100 mg/l, Fish - Pimephales promelas, 96 hours, OECD 203 Chronic NOEL 10 mg/l, Daphnia - Daphnia magna, 21 days, OECD 211 Chronic NOEL >1000 mg/l, Fish - Oncorhynchus mykiss, 21 days

12.1 Toxicity

Product/substance: Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based. Result: Acute EC50 >1000 mg/l, Species: Daphnia, Exposure: 48 hours, Test: OECD 202. Result: Chronic NOEL 10 mg/l, Species: Daphnia, Exposure: 21 days, Test: OECD 202. Result: Chronic NOEL >1000 mg/l, Species: Fish, Exposure: 14 days, Test: -.

12.2 Persistence and degradability

Not available

12.3 Bioaccumulative potential

Not available

12.4 Mobility in soil

Not available

12.5 Results of PBT and vPvB assessment

Not available

12.6 Endocrine disrupting properties

Not available

12.7 Other adverse effects

Not available

12.1 Toxicity

Acute EC50 600 mg/l Algae - Selenastrum capricornutum 72 hours - Acute EC50 >100 mg/l Daphnia - Daphnia magna 48 hours OECD 202 Acute EC50 >1000 mg/l Micro-organism 0.1 days -

12.1 Toxicity

|**Product/substance**|**Result**|**Species**|**Exposure**|**Test**| |C14-16-18 Alkyl phenol|Acute EC50 >100 mg/l|Daphnia - Daphnia magna|48 hours|OECD 202|

12.2 Persistence and degradability

Conclusion/Summary : Not available.

Not available.

12.1 Toxicity

12.2 Persistence and degradability

Not readily

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

No data available.

12.2 Persistence and degradability

|**Product/substance**|**Aquatic half-life**|**Photolysis**|**Biodegradability**| |C15-30, hydrotreated neutral oil-based||||

12.3 Bioaccumulative potential

No data available.

12.4 Mobility in soil

No data available.

12.5 Results of PBT and vPvB assessment

No data available.

12.6 Endocrine disrupting properties

No data available.

12.7 Other adverse effects

No data available.

12.2 Persistence and degradability

bis(nonylphenyl)amine: Not readily

12.3 Bioaccumulative potential

|**Product/substance**|**LogKow**|**BCF**|**Potential**| |---|---|---|---|

12.3 Bioaccumulative potential

Product/substance LogKow BCF Potential Distillates (petroleum), hydrotreated heavy paraffinic Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based|>4 4.1 6.1|- - -|high high high

12.3 Bioaccumulative potential

|**Product/substance**|**LogKow**|**BCF**|**Potential**| Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based|>4 4.1 6.1|- - -|high high high|

12.3 Bioaccumulative potential

|**Product/substance**|**LogKow**|**BCF**|**Potential**| Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based|>4 4.1 6.1|- - - |high high high|

12.3 Bioaccumulative potential

|**Product/substance**|**LogKow**|**BCF**|**Potential**| |bis(nonylphenyl)amine|7.7|1584.89|high|

12.4 Mobility in soil

Soil/water partition coefficient (KOC): Not available. Mobility: Not available. Mobility in soil: Given its physical and chemical characteristics, the product generally shows low soil mobility The product is insoluble and floats on water Loss by evaporation is limited

The product generally shows low soil mobility, is insoluble, floats on water, and has limited evaporation.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances that are assessed to be a PBT or a vPvB.

12.6 Other adverse effects

No known significant effects or critical hazards.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and nonrecyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and nonrecyclable products via a licensed waste disposal contractor.

Waste Codes

13 02 05* Waste codes are not product specific, but application specific; this is a suggestion. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Safety, health and environmental regulations/legislation specific for the substance or mixture

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 030PCXX?

The signal word is no signal word.

What is the physical form of 030PCXX?

030PCXX is a liquid. [limpid] with not available. color. It has characteristic. odor.

What is the solubility of 030PCXX?

Insoluble in the following materials: cold water and hot water.

What is 030PCXX used for?

Engine oil

What are the hazard statements for 030PCXX?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of 030PCXX?

The melting point is Not available. and the boiling point is Not available..