Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 5777D Performance Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 89JP-S5MY-FW24-7UHA
Identified Uses
Petrochemical industry: Viscosity Index Improver
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Alma Court, 50 London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Lenneke Marelaan, 8, B-1932 St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical SRL (Feluy Plant)
manufacturer
Rue de Scoufflény, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Emergency Contacts
Emergency Contact
+43-13649237
Emergency Contact
+351-308801773
Emergency Contact
+32-28083237
Emergency Contact
+421-233057972
Emergency Contact
+359-32570104
Emergency Contact
+38-618888016
Emergency Contact
+385-17776920
Emergency Contact
+46-852503403
SV
Emergency Contact
+420-228880039
Emergency Contact
+41-435082011
Emergency Contact
+45-69918573
Emergency Contact
+380-947101374
Emergency Contact
+358-942419014
Emergency Contact
+44-8708200418
Emergency Contact
+33-975181407
Emergency Contact
+1-703-527-3887
Emergency Contact
+49-69-6435-08409
Emergency Contact
+65-3158-1349
Emergency Contact
+36-18088425
Emergency Contact
+61-290372994
Emergency Contact
+353-19014670
Emergency Contact
4001-204937
Emergency Contact
+39-0245557031
Emergency Contact
+(91)-22-3354 3594
Emergency Contact
+352-20202416
Emergency Contact
+81-345209637
Emergency Contact
+31-858880596
Emergency Contact
00-308-13-2549
Emergency Contact
+47-21930678
Emergency Contact
+1-703-741-5979
Emergency Contact
+48-223988029
Emergency Contact
1-800-424-9300
Emergency Contact
+32 (0)70 245 245
Emergency Contact
+31 (0)30 2748888
Emergency Contact
+45 8212 1212
Emergency Contact
+47 22 59 13 00
Emergency Contact
+33 (0)1 45 42 59 59
Emergency Contact
+351 800 250 250
Emergency Contact
+30 210 779 3777
Emergency Contact
+40 (0)21 318 36 06
8am – 3pm
Emergency Contact
+34 91 562 04 20
Emergency Contact
+371 67042473
Emergency Contact
+43-13649237
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | 64742-65-0 | 45 - 55% | Yes |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 35 - 45% | No |
| Alcohols, C12-14, ethoxylated(even numbered) 1-2.5EO EC: 500-213-3 | --- | 1 - 3% | Yes |
The mineral oils in the product contain < 3% DMSO extract (IP 346).
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.
Symptoms: No known significant effects or critical hazards. No specific data.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes.
Symptoms: No known significant effects or critical hazards. No specific data.
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses.
Symptoms: No known significant effects or critical hazards. No specific data.
Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.
Symptoms: No known significant effects or critical hazards. No specific data.
Immediate Medical Attention
Get medical attention if symptoms occur.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical orCO₂.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for firefighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material.
Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 5777D Performance Additive
---
HiTEC® 5777D Performance Additive
UFI: 89JP-S5MY-FW24-7UHA
HiTEC® 5777E Performance Additive
UFI: FFDK-S469-UJ2C-QMNQ
HiTEC® 5777 Performance Additive
UFI: KT6G-7445-WJ2R-PD3K
HiTEC® 5777 Performance Additive
UFI: KT6G-7445-WJ2R-PD3K
HiTEC® 5739 Performance Additive
---
HiTEC® 5754A Performance Additive
UFI: PA7C-66DK-893A-E4CQ
HiTEC® 5754A Performance Additive
UFI: PA7C-66DK-893A-E4CQ
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8).
Store in original container protected from direct sunlight in a dry, cool and wellventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.
Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer’s directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Under recommended handling and storage conditions the product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Toxic to aquatic life.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
Based on available data, the classification criteria are not met.
12.4 Mobility in soil
Not available.
12.5 Results of PBT and vPvB assessment
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3257
- Shipping Name
- Elevated temperature liquid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product contains only components that have been either registered, are exempt from registration, are regarded as registered or are not subject to registration according to Regulation (EC) No.1907/2006 (REACH) and amendments.
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 5777D Performance Additive?
The signal word is no signal word.
What is the physical form of HiTEC® 5777D Performance Additive?
HiTEC® 5777D Performance Additive is a liquid. [clear to slightly hazy liquid. viscous liquid.] appearing as clear to slightly hazy liquid. viscous liquid. with brown. color. It has petroleum odor.
What is the solubility of HiTEC® 5777D Performance Additive?
Not available.
What is HiTEC® 5777D Performance Additive used for?
Petrochemical industry: Viscosity Index Improver
What is the melting point of HiTEC® 5777D Performance Additive?
The melting point is Not available. and the boiling point is Not available..