Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIANOL 1990
- Product Form
- Substance (UVCB)
- Chemical Name
- Fatty acids, C18-unsatd., dimers, di-Me esters, hydrogenated
Regulatory Identifiers
- CAS Number
- 147853-32-5 Check regulations →
- EC Number
- 604-608-2 Check regulations →
- REACH No.
- 01-2119976280-36
Identified Uses
Uses at industrial sites of transported intermediates Manufacturing of transported intermediates Formulation of transported intermediates
Uses advised against
No additional information available
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2, 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
SGS ERS
+32 3 575 55 55
SGS ERS
+1 888 765 6554
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Dimer diol EC: 604-608-2 | 147853-32-5 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Symptoms: No effects known.
Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.
Symptoms: Tingling/irritation of the skin.
Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.
Symptoms: No effects known.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Symptoms: No effects known.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.
Solid water jet ineffective as extinguishing medium.
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. No direct explosion hazard.
No specific fire-fighting instructions required.
Firefighter Protection
Heat/fire exposure: compressed air/oxygen apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes. No naked flames.
Prevent soil and water pollution.
Clean contaminated surfaces with an excess of water and soap solution. Take up liquid spill into inert absorbent material, e.g.: dry sand/earth/vermiculite or powdered limestone.
Materials: dry sand/earth/vermiculite or powdered limestone
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from naked flames/heat. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks. Carry operations in the open/under local exhaust/ventilation or with respiratory protection. Comply with the legal requirements. Clean contaminated clothing. Keep container tightly closed.
Keep container tightly closed.
Clean contaminated clothing.
Keep away from naked flames/heat. In finely divided state: use spark-/explosionproof appliances. Finely divided: keep away from ignition sources/sparks.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gloves
Not required for normal conditions of use
Respiratory protection not required in normal conditions
Protective clothing. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Take up liquid spill into absorbent material, Scoop absorbed substance into closing containers, Carefully collect the spill/leftovers, Clean contaminated surfaces with an excess of water, Wash clothing and equipment after handling
Use appropriate containment to avoid environmental contamination. Remove waste in accordance with local and/or national regulations. Recycle/reuse.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulatory status for RADIANOL 1990
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIANOL 1990?
The signal word is no signal word.
What is the physical form of RADIANOL 1990?
RADIANOL 1990 is a liquid appearing as viscous. liquid. with colourless to yellow. color. It has mild odour. odor.
What is the solubility of RADIANOL 1990?
Poorly soluble in water. Water: < 0,1 mg/l (pH 6.7; column elution method)
What is RADIANOL 1990 used for?
Uses at industrial sites of transported intermediates Manufacturing of transported intermediates Formulation of transported intermediates
What is the melting point of RADIANOL 1990?
The melting point is < -10 °C and the boiling point is ca. 430 °C (1013 hPa; DSC).