NextSDS Logo
Safety Data Sheet EN

Delo Syn-TDL SAE 75W-90

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Delo Syn-TDL SAE 75W-90
Product Code
804131

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Axle Oil

Manufacturers & Suppliers

C

Chevron Belgium BVBA

manufacturer

Technologiepark-Zwijnaarde 88 B-9052 Gent Belgium

Emergency Contacts

CHEMTREC

+1 703 527 3887

Europe

0044/(0)18 65 407333

EN

Chevron Emergency Information Center

+1 510 231 0623

24 hours

Europe

0044/(0)18 65 407333

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Dec-1-ene, homopolymer, hydrogenated EC: 500-183-1 68037-01-4 40 - 70% Yes
Polysulfides, di-tert-Bu --- 1 - 5% Yes
Highly refined mineral oil (C15-C50) --- 1 - 5% No
Phosphoric acid ester, amine salt EC: 931-384-6 --- 1 - 2.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If exposed to excessive levels of material in the air, move the exposed person to fresh air. If exposure to hydrogen sulfide (H2S) gas is possible during an emergency, move the exposed person to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.

Symptoms: Not expected to be harmful if inhaled. Contains a synthetic hydrocarbon oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing. Hydrogen sulfide has a strong rotten-egg odor. However, with continued exposure and at high levels, H2S may deaden a person's sense of smell. If the rotten egg odor is no longer noticeable, it may not necessarily mean that exposure has stopped. At low levels, hydrogen sulfide causes irritation of the eyes, nose, and throat. Moderate levels can cause headache, dizziness, nausea, and vomiting, as well as coughing and difficulty breathing. Higher levels can cause shock, convulsions, coma, and death. After a serious exposure, symptoms usually begin immediately.

Skin contact

Remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

Symptoms: Contact with the skin is not expected to be harmful.

Eye contact

Remove contact lenses, if worn, and flush eyes with water.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

Do not induce vomiting.

Symptoms: Not expected to be harmful if swallowed.

Immediate Medical Attention

Get medical attention if coughing or respiratory discomfort occurs. Get immediate medical attention.

Medical Treatment

Administration of 100% oxygen and supportive care is the preferred treatment for poisoning by hydrogen sulfide gas.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Specific hazards

A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion. Combustion may form oxides of: Sulfur, Phosphorus, Nitrogen.

Instructions

For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

Firefighter Protection

Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Eliminate all sources of ignition in vicinity of spilled material. Refer to Sections 5 and 8 for more information.

Environmental

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.

Cleanup methods

Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe gas. Wash thoroughly after handling. Toxic quantities of hydrogen sulfide (H2S) may be present in storage tanks and bulk transport vessels which contain or have contained this material. Persons opening or entering these compartments should first determine if H2S is present. Do not attempt rescue of a person over exposed to H2S without wearing approved supplied-air or self-contained breathing equipment. If there is a potential for exceeding one-half the occupational exposure standard, monitoring of hydrogen sulfide levels is required. Since the sense of smell cannot be relied upon to detect the presence of H2S, the concentration should be measured by the use of fixed or portable devices.

Storage

Not Applicable

Hygiene

Wash thoroughly after handling.

Fire prevention

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere and use appropriate mitigating procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Suggested materials for protective gloves include: 4H (PE/EVAL), Nitrile Rubber, Silver Shield, Viton.

Eyes

No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.

Respiratory

No respiratory protection is normally required. If material is heated and emits hydrogen sulfide, determine if airborne concentrations are below the occupational exposure limit for hydrogen sulfide. If not, wear an approved positive pressure air-supplying respirator. For more information on hydrogen sulfide, see Chevron MSDS No. 301. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.

Skin/Body

No special protective clothing is normally required. Where splashing is possible, select protective clothing depending on operations conducted, physical requirements and other substances in the workplace.

Environmental

See relevant Community environmental protection legislation or the Annex, as applicable.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Amber
Colour
Amber
Colour Intensity
---
Form
---
Odor
Petroleum odor
Odor Threshold
No data available
Ph
Not Applicable
Melting Point
No data available
Boiling Point
No data available
Flash Point
(Cleveland Open Cup) 198 °C (388 °F) (Typical)
Freezing Point
Not Applicable
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
---
Bulk Density
---
Density
0.86 kg/l @ 15°C (59°F) (Typical)
Flammability
Not Applicable
Upper Explosive Limit
Not Applicable
Lower Explosive Limit
Not Applicable
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Soluble in hydrocarbons; insoluble in water
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
98 mm2/s @ 40°C (104°F) (Typical)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Not applicable

Incompatible

Not applicable

Decomposition

Hydrogen Sulfide (Elevated temperatures), Alkyl Mercaptans (Elevated temperatures)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

This material is not expected to be harmful to aquatic organisms. The product has not been tested. The statement has been derived from the properties of the individual components.

12.2 Persistence and degradability

This material is not expected to be readily biodegradable. The product has not been tested. The statement has been derived from the properties of the individual components.

12.3 Bioaccumulative potential

Bioconcentration Factor: No Data Available Octanol/Water Partition Coefficient: No data available

12.4 Mobility in soil

No data available.

12.5 Results of PBT and vPvB assessment

This product is not, or does not contain, a substance that is a potential PBT or a vPvB.

The product is not, or does not contain, a substance that is a potential PBT or a vPvB.

12.1 Toxicity

Acute Toxicity: Dec-1-ene,homopolymer,hydrogenated | Based on available data, the classification criteria are not met

12.1 Toxicity

Polysulfides, di-tert-Bu Test Qualifier: LC50 Test Result: >100mg/l mg/l Species: Fish Duration:96hour(s)

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

Highlyrefinedmineraloil(C15-C50) Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met.

Acute Toxicity

Phosphoric acid ester, amine salt Test Qualifier: LC50 Test Result: 2-10 mg/l Species: Fish Duration:96hour(s)

12.1 Toxicity

Long-term Toxicity: Dec-1-ene,homopolymer,hydrogenated: Based on available data, the classification criteria are not met

12.1 Toxicity

Long-term Toxicity: Polysulfides, di-tert-Bu: No test data available

12.1 Toxicity

Highlyrefinedmineraloil(C15-C50) Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

12.1 Toxicity

Long-term Toxicity: No test data available

12.2 Persistence and degradability

Biodegradation: Based on available data, the classification criteria are not met

Persistence and degradability

Biodegradation: 0% | Protocol: 40CFR796.3200-Closed Bottle Test Result: Not readily biodegradable

12.2 Persistence and degradability

Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

Biodegradation

Phosphoric acid ester, amine salt | Protocol: OECD 301B-Modified Sturm Test | Result: Not readily biodegradable. Biodegradation: 9.4%

The substance is not readily biodegradable (9.4% biodegradation).

Bioaccumulative Potential

Based onavailable data, the classificationcriteria arenotmet

Based on available data, the classification criteria are not met

Bioaccumulative Potential

Polysulfides, di-tert-Bu | No test data available

No test data available

Bioaccumulative Potential

Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

Bioaccumulative Potential

Phosphoric acid ester, amine salt: No test data available

No test data available

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.

Disposal

Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.

Waste Codes

13 02 08 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No components of this material were found on the regulatory lists searched (EU Directives 76/769/EEC, 90/394/EEC, 92/85/EEC, 96/82/EC, 98/24/EC, 2004/37/EC, EU Regulations 689/2008, 850/2004, REACH Annex XVII, and REACH Annex XIV).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Delo Syn-TDL SAE 75W-90?

The signal word is no signal word.

What is the physical form of Delo Syn-TDL SAE 75W-90?

Delo Syn-TDL SAE 75W-90 is a liquid appearing as amber with amber color. It has petroleum odor odor.

What is the solubility of Delo Syn-TDL SAE 75W-90?

Soluble in hydrocarbons; insoluble in water

What is Delo Syn-TDL SAE 75W-90 used for?

Axle Oil

What is the melting point of Delo Syn-TDL SAE 75W-90?

The melting point is No data available and the boiling point is No data available.