NextSDS Logo
Safety Data Sheet EN

RADIA 3812

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIA 3812
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial use wide dispersive use

Uses advised against

No additional information available

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2 9940 Ertvelde - Belgium

+32 9 341 10 11

http://www.oleon.com

Emergency Contacts

24/7 EMERGENCY NUMBER (SGS ERS; Oleon contract nr 76858)

+32 3 575 55 55

24/7

24/7 EMERGENCY NUMBER (SGS ERS; Oleon contract nr 76858)

+1 888 765 6554

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H315 Causes skin irritation.
H318 Causes serious eye damage.

Precautionary Statements

P264 Wash hands, forearms and face thoroughly after handling.
P280 Wear face shield, protective clothing, protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call emergency phone number.
P321 Specific treatment (see specific cleansing agent(s) on this label).

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Glycerin --- 50% No
Fatty acids, C8-18 and C18-unsatd. (archive from 12.2016) EC: 266-929-0 67701-05-7 50% Yes

Notes

Composition of product is highly variable

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Skin contact

Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.

Eye contact

Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.

Ingestion

Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.

Unsuitable media

Solid water jet ineffective as extinguishing medium.

Specific hazards

DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.

Environmental

Prevent soil and water pollution.

Cleanup methods

Clean contaminated surfaces with an excess of water and soap solution. Take up liquid spill into inert absorbent material, e.g.: dry sand/earth/vermiculite or powdered limestone.

Materials: water and soap solution, dry sand/earth/vermiculite or powdered limestone

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling temperature : ≥ 10 °C above melting point

Storage

Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.

Fire prevention

KEEP SUBSTANCE AWAY FROM: ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves

Eyes

Safety glasses

Skin/Body

Protective clothing. GIVE GOOD RESISTANCE: nitrile rubber

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
No supplementary information available.
Colour
No supplementary information available.
Colour Intensity
---
Form
---
Odor
Characteristic odour. Sweet odour.
Odor Threshold
No data available
Ph
No data available
Melting Point
No supplementary information available
Boiling Point
> 150 °C
Flash Point
> 120 °C
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
No data available
Evaporation Rate
No data available
Vapor Pressure
No supplementary information available
Vapor Density
No data available
Relative Density
No data available
Bulk Density
---
Density
ca. 906 kg/m³ (20°C)
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
> 250 °C
Decomposition Temperature
> Flash point
Solubility
Insoluble in water. Soluble in oils/fats. soluble in most organic solvents.
Partition Coefficient
No data available
Solubility In Water
Insoluble in water.
Solubility In Fat
Soluble in oils/fats.
Molecular Weight
---
Voc Content
not determined (1999/13/EC; 2004/42/EC; 2010/75/EU)
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

On burning: release of (carbon monoxide - carbon dioxide).

Hazardous reactions

No additional information available

Avoid

No supplementary information available.

Incompatible

No supplementary information available.

Decomposition

No supplementary information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Ecology - general : No supplementary information available. Ecology - air : No supplementary information available. Ecology - water : No supplementary information available Acute aquatic toxicity : Not classified Chronic aquatic toxicity : Not classified Glycerin LC50 fish 1 54000 mg/l (96 h, SALMO GAIRDNERI/ ONCORHYNCHUS MYKISS) LC50 fish 2 > 1000 mg/l (96 h, PISCES) LC50 other aquatic organisms 1 > 1000 mg/l (96 h) EC50 Daphnia 2 > 10000 mg/l (24 h, DAPHNIA MAGNA, LOCOMOTOR EFFECT) EC50 other aquatic organisms 1 > 1000 mg/l (BACTERIA, ACTIVATED SLUDGE) TLM fish 1 > 1000 ppm (96 h, PISCES) TLM other aquatic organisms 1 > 1000 ppm (96 h) Threshold limit other aquatic organisms 1 2900 mg/l (192 h, MICROCYSTIS AERUGINOSA, TOXICITY TEST) Threshold limit other aquatic organisms 2 > 10000 mg/l (16 h, PSEUDOMONAS PUTIDA, TOXICITY TEST) Threshold limit algae 1 > 10000 mg/l (168 h, SCENEDESMUS QUADRICAUDA, TOXICITY TEST)

12.1. Toxicity

Ecology - general : No supplementary information available. Ecology - air : No supplementary information available. Ecology - water : No supplementary information available Acute aquatic toxicity : Not classified Chronic aquatic toxicity : Not classified Fatty acids, C8-18 and C18-unsatd. (archive from 12.2016) (67701-05-7) LC50 fish 1 ca. 300 mg/l 96h (Danio rerio)

The substance is not classified for acute or chronic aquatic toxicity. The LC50 for fish (Danio rerio) is approximately 300 mg/L.

12.2. Persistence and degradability

12.2. Persistence and degradability

12.2. Persistence and degradability

Glycerin Biochemical oxygen demand (BOD) 0,87 g O2/g substance Chemical oxygen demand (COD) 1,16 g O2/g substance (ISO 15705) ThOD 1,217 g O2/g substance BOD (% of ThOD) 71 % ThOD

12.2. Persistence and degradability

Fatty acids, C8-18 and C18-unsatd. (archive from 12.2016) (67701-05-7) ThOD 2,9 g O2/g substance

12.3. Bioaccumulativepotential

12.3. Bioaccumulativepotential

Log Pow -1,75 (Experimental value, Equivalent or similar to OECD 107, 25 °C)

12.3. Bioaccumulativepotential

Fatty acids, C8-18 and C18-unsatd. (archive from 12.2016) (67701-05-7) Log Pow > 5 (est.)

12.4. Mobility in soil

|**12.4. Mobility in soil**|| |**Glycerin**|| |Surface tension|0,063 N/m (20°C)| |Ecology - soil|Biodegradability in soil: no data available.| |**Fatty acids, C8-18 and C18-unsatd. (archive f**|**rom 12.2016) (67701-05-7)**| |---|---| |Surface tension|ca. 0,03 N/m (20°C)| |Ecology - soil|Biodegradability in soil: no data available.|

12.5. Results of PBT and vPvB assessment

No additional information available

No additional information available

12.6. Other adverse effects

No additional information available

No additional information available

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling

Disposal

Remove to an authorized waste treatment plant.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Safety, health and environmental regulations/legislation specific for the substance or mixture

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIA 3812?

The signal word is danger.

What is the physical form of RADIA 3812?

RADIA 3812 is a liquid appearing as no supplementary information available. with no supplementary information available. color. It has characteristic odour. sweet odour. odor.

What is the solubility of RADIA 3812?

Insoluble in water. Soluble in oils/fats. soluble in most organic solvents.

What is RADIA 3812 used for?

Industrial use wide dispersive use

What are the hazard statements for RADIA 3812?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.

What is the melting point of RADIA 3812?

The melting point is No supplementary information available and the boiling point is > 150 °C.