NextSDS Logo
Safety Data Sheet EN

RADIACID 0189

CAS 93165-31-2
EC 296-916-5

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIACID 0189
Product Form
Substance (UVCB)
Chemical Name
Fatty acids, rape-oil, erucic acid-low

Regulatory Identifiers

CAS Number
93165-31-2 Check regulations →
EC Number
296-916-5 Check regulations →

Identified Uses

Industrial use

Uses advised against

No additional information available

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2, 9940 Ertvelde - Belgium

+32 9 341 10 11

http://www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

24/7

SGS ERS

+1 888 765 6554

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb

Substance type : UVCB

Chemical Name CAS Number Concentration Hazardous
Fatty acids, rape-oil, erucic acid-low EC: 296-916-5 93165-31-2 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Symptoms: ON HEATING: Irritation of the respiratory tract.

Skin contact

Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.

Eye contact

Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.

Ingestion

Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.

Unsuitable media

Solid water jet ineffective as extinguishing medium.

Specific hazards

DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. DIRECT EXPLOSION HAZARD: Fine dust is explosive with air. INDIRECT EXPLOSION HAZARD: Dust cloud can be ignited by a spark.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.

Environmental

Prevent soil and water pollution.

Cleanup methods

Carefully collect the spill/leftovers. If melted: allow liquid to solidify before taking it up. Scoop solid spill into closing containers or into synthetic bags. Clean contaminated surfaces with an excess of water and soap solution.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling temperature: ≥ 10 °C above melting point

Storage

Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.

Fire prevention

KEEP SUBSTANCE AWAY FROM: ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves. GIVE GOOD RESISTANCE: nitrile rubber

Eyes

Safety glasses.

Skin/Body

Protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid.
Colour
Light yellow to dark yellow.
Colour Intensity
---
Form
---
Odor
Characteristic odour. Mild odour.
Odor Threshold
No data available
Ph
< 7
Melting Point
ca. 9 °C
Boiling Point
> 250 °C
Flash Point
> 180 °C (ASTM D92)
Freezing Point
ca. 8 °C (4-17)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
< 0,01 hPa (20°C)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 895,1 kg/m³ (20°C) ca. 881,2 kg/m³ (40°C) ca. 839,5 kg/m³ (100°C)
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
> 300 °C
Decomposition Temperature
> Flash point
Solubility
Water: < 0,005 g/100ml (25°C)
Partition Coefficient
> 5 (est.)
Solubility In Water
Poorly soluble in water.
Solubility In Fat
Soluble in oils/fats.
Molecular Weight
---
Voc Content
< 0,1 % (1999/13/EC; 2004/42/EC; 2010/75/EU)
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
ca. 35 mm²/s (30-40)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

On burning: release of (carbon monoxide - carbon dioxide).

Hazardous reactions

No additional information available

Avoid

No supplementary information available.

Incompatible

No supplementary information available.

Decomposition

No supplementary information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Ecology - general : According to literature: no environmental hazard. Ecology - air : No supplementary information available. Ecology - water : No bioaccumulation data available Acute aquatic toxicity : Not classified Chronic aquatic toxicity : Not classified

According to literature: no environmental hazard.

12.2. Persistence and degradability

### RADIACID 0189 (93165-31-2)

12.2. Persistence and degradability

RADIACID 0189 (93165-31-2) | Persistence and degradability | Readily biodegradable, according to appropriate OECD test. | | --- | --- | | ThOD | 2,9 g O2/g substance |

12.3. Bioaccumulative potential

RADIACID 0189 (93165-31-2) | Log Pow | > 5 (est.) |

12.4. Mobility in soil

RADIACID 0189 (93165-31-2) | Surface tension | ca. 0,03 N/m (20°C) |

12.5. Results of PBT and vPvB assessment

No additional information available

12.6. Other adverse effects

No additional information available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Remove to an authorized waste treatment plant.

Disposal

Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Regulatory information for RADIACID 0189 (CAS RN: 85711-54-2)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIACID 0189?

The signal word is no signal word.

What is the physical form of RADIACID 0189?

RADIACID 0189 is a liquid appearing as liquid. with light yellow to dark yellow. color. It has characteristic odour. mild odour. odor.

What is the solubility of RADIACID 0189?

Water: < 0,005 g/100ml (25°C)

What is RADIACID 0189 used for?

Industrial use

What is the melting point of RADIACID 0189?

The melting point is ca. 9 °C and the boiling point is > 250 °C.