Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- STEEL-IT 1002B Polyurethane Aerosol – Steel Gray
- Product Code
- FGAE1002B (14 oz.), FGAE1002C (4.5 oz.), CASE1002B (case of 12 FGAE1002B), CASE1002C (case of 12 FGAE1002C)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Paint / Industrial coating (topcoat). Category: Pigmented metallic coating.
Uses advised against
Uses other than the recommended use. Do not spray on an open flame or other ignition source.
Manufacturers & Suppliers
Stainless Steel Coatings, Inc.
manufacturer
835 Sterling Road Lancaster, MA 01523-2915 United States of America
978-365-9828
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS04
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Benzene, 1-chloro-4-(trifluoromethyl)- | 98-56-6 | 15 - 25% | No |
| Propane | 74-98-6 | 10 - 20% | No |
| Acetone | 67-64-1 | 5 - 15% | No |
| Distillates (petroleum), hydrotreated light | 64742-47-8 | 5 - 15% | No |
| Butane | 106-97-8 | 5 - 10% | No |
| Chromium | 7440-47-3 | 2% | No |
| C.I. Pigment black 028 | 68186-91-4 | 2% | No |
| Xylene | 1330-20-7 | 2% | No |
| Nickel | 7440-02-0 | 2% | No |
| Ethylbenzene | 100-41-4 | 0.4% | No |
| C.I. Pigment blue 28 | 1345-16-0 | 0.3% | No |
| Butanone oxime | 96-29-7 | 0.2% | No |
Notes
All concentrations are in percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume. Components not listed are either non-hazardous or are below reportable limits.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation. Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention immediately.
Symptoms: respiratory tract irritation, dizziness, nausea, or unconsciousness
Remove contaminated clothing immediately and wash skin with soap and water. In case of eczema or other skin disorders: Seek medical attention and take along these instructions.
Symptoms: Skin irritation. May cause redness and pain. May cause an allergic skin reaction. Dermatitis. Rash.
Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.
Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.
In the unlikely event of swallowing contact a physician or poison control center. Rinse mouth. Do not induce vomiting without advice from poison control center. If vomiting occurs, keep head low so that stomach content doesn't get into the lungs.
Symptoms: Nausea, vomiting
Immediate Medical Attention
Get medical attention immediately (inhalation). Seek medical attention (skin). Get medical attention if irritation develops and persists (eye). Contact a physician or poison control center (ingestion). Keep victim under observation.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Alcohol resistant foam. Dry chemical powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
Contents under pressure. Pressurized container may explode when exposed to heat or flame.
In case of fire: Stop leak if safe to do so. Move containers from fire area if you can do so without risk. Containers should be cooled with water to prevent vapor pressure build up. Fight fire from protected location or safe distance. For massive fire in cargo area, use unmanned hose holder or monitor nozzles, if possible. If not, withdraw and let fire burn out.
Firefighter Protection
Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the leak is irreparable. Isolate area until gas has dispersed. Ventilate closed spaces before entering them.
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into drains, water courses or onto the ground.
Pick up undamaged aerosol cans mechanically. Absorb in vermiculite, dry sand or earth and place into containers. Scoop up used absorbent into drums or other appropriate container. Following product recovery, flush area with water.
Materials: vermiculite, dry sand or earth
Related Products
Similar products with comparable safety profiles
STEEL-IT 4907A Epoxy Topcoat, Part A
---
STEELGUARD 651 WHITE
---
Dykem® Transparent Stain Aerosol - Steel Blue and Steel Red
---
Premium Polyurethane Construction Adhesive Sealant - Gray
---
Interthane 990 Aerosol RAL7045 Telegrey Part A
---
Interthane 990 Aerosol RAL9005 Jet Black Part A
---
SHER-WOOD VINYL BASECOAT DT SW 7075 WEB GRAY
---
DIRECT TO RUST METAL PAINT SMOOTH AEROSOL BLACK
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Pressurized container: Do not pierce or burn, even after use. Do not use if spray button is missing or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the product must be grounded. Avoid breathing mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Avoid prolonged exposure. When using, do not eat, drink or smoke. Persons susceptible for allergic reactions should not handle this product. Pregnant or breastfeeding women must not handle this product. Should be handled in closed systems, if possible. Mechanical ventilation or local exhaust ventilation may be required. Do not enter storage areas or confined spaces unless adequately ventilated. Use only outdoors or in a well-ventilated area. Oxygen concentration should not fall below 19.5 % at sea level (pO2 = 135 mmHg). Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Avoid release to the environment. Observe good industrial hygiene practices.
Store locked up. Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50°C/122 °F. Keep away from heat, sparks and open flame. Store in original tightly closed container. Store in a well-ventilated place. Stored containers should be periodically checked for general condition and leakage. Store away from incompatible materials.
When using, do not eat, drink or smoke. Wash hands thoroughly after handling. Observe good industrial hygiene practices.
Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the product must be grounded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Contents under pressure. Do not puncture. Protect against direct sunlight. Avoid heat, sparks, open flames and other ignition sources. In a fire or if heated, a pressure increase will occur and the container may burst or explode. Contact with incompatible materials.
Strong oxidizing agents. Strong acids. Halogens. Chlorine.
Thermal decomposition of this product can generate carbon monoxide and carbon dioxide. Fumes of metal oxides. Chlorine compounds. Fluorine compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Mobility in soil
The product is insoluble in water and is not expected to be mobile in soil.
Other adverse effects
The product contains volatile organic compounds with photochemical ozone creation potential and is identified as containing hazardous air pollutants (HAPs) under the US Federal Clean Air Act.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Incinerate the material under controlled conditions in an approved incinerator.
Collect and reclaim or dispose in sealed containers at licensed waste disposal site.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- Aerosols, flammable
- Transport Class
- 2.1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for STEEL-IT 1002B Polyurethane Aerosol – Steel Gray?
The signal word is danger.
What is the physical form of STEEL-IT 1002B Polyurethane Aerosol – Steel Gray?
STEEL-IT 1002B Polyurethane Aerosol – Steel Gray is a aerosol with gray. color. It has characteristic of solvents. odor.
What is STEEL-IT 1002B Polyurethane Aerosol – Steel Gray used for?
Paint / Industrial coating (topcoat). Category: Pigmented metallic coating.
What are the hazard statements for STEEL-IT 1002B Polyurethane Aerosol – Steel Gray?
This substance has 11 hazard statements:
- H222: Extremely flammable aerosol.
- H280: Contains gas under pressure; may explode if heated.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H350: May cause cancer.
- H361: Suspected of damaging fertility or the unborn child by inhalation.
- H372: Causes damage to organs (respiratory tract) through prolonged or repeated exposure by inhalation.
- H411: Toxic to aquatic life with long lasting effects.
- May displace oxygen and cause rapid suffocation.
What is the melting point of STEEL-IT 1002B Polyurethane Aerosol – Steel Gray?