Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AZD6765 dihydrochloride
- Product Code
- SML0635
Regulatory Identifiers
- CAS Number
- 153322-06-6 Check regulations →
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| AZD6765 dihydrochloride | 153322-06-6 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
If swallowed: give water to drink (two glasses at most). Seek medical advice immediately. In exceptional cases only, if medical care is not available within one hour, induce vomiting (only in persons who are wide awake and fully conscious), administer activated charcoal (20 - 40 g in a 10% slurry) and consult a doctor as quickly as possible.
Immediate Medical Attention
Seek medical advice immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Nitrogen oxides (NOx), Hydrogen chloride gas. Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up carefully. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Y-27632 (Dihydrochloride)
---
Y-27632 (Dihydrochloride)
---
Y-27632 (dihydrochloride)
CAS: 129830-38-2
PH-797804
CAS: 586379-66-0
E122 AZORUBINE GRANULAR HT
CAS: 3567-69-9
TRIS (HYDROXYMETHYL) AMINOMETHANE HYDROCHLORIDE SALT
CAS: 1185-53-1
1-(1-adamantyl)piperazine dihydrochloride
CAS: 30537-92-9
Ziprasidone Hydrochloride Monohydrate
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P3. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
No data available
no information available
Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture does not contain PBT or vPvB components at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
No data available
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2811
- Shipping Name
- TOXIC SOLID, ORGANIC, N.O.S. (AZD6765 dihydrochloride)
- Transport Class
- 6.1
- Packing Group
- III
Tunnel restriction code : (E)
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AZD6765 dihydrochloride?
The signal word is danger.
What is the physical form of AZD6765 dihydrochloride?
AZD6765 dihydrochloride is a solid with no data available color. It has no data available odor.
What is AZD6765 dihydrochloride used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for AZD6765 dihydrochloride?
This substance has 1 hazard statement:
- H301: Toxic if swallowed.
What is the melting point of AZD6765 dihydrochloride?
The melting point is No data available and the boiling point is No data available.