Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MAP® AQ PUK durcisseur
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
See the Technical Data Sheet of the product.
Uses advised against
Any use not described in the Technical Data Sheet of the product.
Manufacturers & Suppliers
MAP SPACE COATINGS S.A.S.
manufacturer
ZI de Bonzom 1 rue Paul MAES 09270 MAZERES - FRANCE
+33 5 34 01 27 00
Emergency Contacts
National Poisons Information Service (NPIS)
(+44) 844 892 0111
National Poisons Information Service (NPIS)
0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyisocyanate aliphatique hydrophile | 666723-27-9 | 70 - 80% | Yes |
| Acétate de 2-méthoxy-1-méthyléthyle EC: 203-603-9 | 108-65-6 | 25 - 30% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is irregular or stopped, administer artificial respiration.
Immediately take off all contaminated clothing. Areas of the body that have - or are only even suspected of having - come into contact with the product must be rinsed immediately with plenty of running water and possibly with soap. Wash thoroughly the body (shower or bath). Remove contaminated clothing immediately and dispose off safely.
In case of contact with eyes, rinse immediately with plenty of water.
Do NOT induce vomiting.
Immediate Medical Attention
In case of contact with eyes, seek medical advice. In case of inhalation, consult a doctor immediately and show him packing or label.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide ( CO2), Sprayed(Pulverized) water or fog of water, Foam, Multi-purpose(Versatile) powders ABC. In case of fire: use some dry chemical powder, the CO2, the sprayed(pulverized) water or the foam(moss) for the extinction.
Do not inhale explosion and combustion gases. Burning produces heavy smoke.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove all sources of ignition. Wear breathing apparatus if exposed to vapours/dusts/aerosols. Provide adequate ventilation. Use appropriate respiratory protection. See protective measures under point 7 and 8.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Wash with plenty of water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists. Don't use empty container before they have been cleaned. Before making transfer operations, assure that there aren't any incompatible material residuals in the containers.
Cool and adequately ventilated.
Contaminated clothing should be changed before entering eating areas. Do not eat or drink while working.
Keep away from unguarded flame, sparks, and heat sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
One-time gloves.
Eye glasses with side protection.
protective mask A2P2
Lab coat.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Sensitive to the humidity
Stable under normal conditions
Exothermic reaction with Amines and alcohols; with the water progressive release (clearance) of CO2; in closed bowls, increase of the pressure, where from the risk of explosion of bowls.
Heat, Humidity
Avoid contact with combustible materials. The product could catch fire.
Carbon dioxide, Isocyanates, Carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1. Toxicity
12.1. Toxicity
12.1. Toxicity
12.5. Results of PBT and vPvB assessment
The substance is not considered to be PBT or vPvB.
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recover, if possible. Send to authorised disposal plants or for incineration under controlled conditions.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MAP® AQ PUK durcisseur?
The signal word is warning.
What is the physical form of MAP® AQ PUK durcisseur?
MAP® AQ PUK durcisseur is a liquid appearing as n.a. with n.a. color. It has solvantée odor.
What is MAP® AQ PUK durcisseur used for?
See the Technical Data Sheet of the product.
What are the hazard statements for MAP® AQ PUK durcisseur?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapour.
- H317: May cause an allergic skin reaction.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of MAP® AQ PUK durcisseur?
The melting point is Not available and the boiling point is Not available.