NextSDS Logo
Safety Data Sheet EN

Medidrug® DOA S

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Medidrug® DOA S
Product Code
24SL01GF, 24SL03GF
Synonyms
Drugs of Abuse in serum

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For in vitro diagnostic use

Manufacturers & Suppliers

M

MEDICHEM Diagnostica GmbH

manufacturer

Kringstraße 3-5, 71144 Steinenbronn

Emergency Contacts

Emergency Contact

+49 7157 / 5304-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product does not contain any hazardous constituents in appreciable concentrations.

Chemical Name CAS Number Concentration Hazardous
Human serum --- --- No
Stabilizing substance --- --- No
Spiked substances: Drugs of Abuse --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Not applicable

Skin contact

Immediately wash off the affected skin areas using plenty of soap and water. Disinfection.

Symptoms: May cause irritation to skin.

Eye contact

Widen eyelids and immediately and extensively (15 minutes) rinse eyes under running water (protect unaffected eye, remove contact lenses).

Symptoms: May cause irritation to eyes.

Ingestion

After swallowing immediately rinse out mouth with suitable disinfectant solution.

Immediate Medical Attention

Ophthalmologist. Medical help.

Medical Treatment

Appropriate symptomatic treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All known extinguishing agents, adjust to suit environment. The usual measures for clinical chemical laboratories apply.

Unsuitable media

Not applicable

Specific hazards

Special hazards are not to be feared.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

To treat like potentially infectious patient samples.

Environmental

Special hazards are not to be feared.

Cleanup methods

Clean up area using plenty of water. Disinfection.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

May only be used by competent specialist, inducted staff.

Storage

Store at temperatures between 2° - 8°C

Fire prevention

Not combustible.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Yes

Eyes

Yes

Respiratory

Not applicable

Skin/Body

Laboratory coat

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Yellowish
Colour Intensity
---
Form
Lyophilizate
Odor
Odourless
Odor Threshold
---
Ph
Approx. 7 after reconstitution
Melting Point
Not applicable
Boiling Point
105°C
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
like H₂O
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Approx. 1.02 g/cm³ after reconstitution
Flammability
---
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Very good
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Not applicable

Reactivity

Not known, if handled correctly by competent specialist, inducted staff.

Hazardous reactions

Not applicable

Avoid

High temperatures

Incompatible

Not applicable

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Not determined

12.2 Persistence and degradability

Not determined

Not determined

12.3 Bioaccumulative potential

Not determined

Not determined

Mobility in soil

Not determined

Not determined

12.5 Results of PBT and vPvB assessment

Not determined

12.6 Other harmful effects

Not determined

Not determined

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Appropriate laws or directives of the EU member states respectively control the disposal of such waste. Please contact the applicable office (authority or waste disposal company) and they will inform you regarding disposal.

Disposal

As a rule, residual materials of human origin are regarded as hazardous waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Designation according to EU regulations: Not applicable

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Medidrug® DOA S known by?

Medidrug® DOA S is also known as: Drugs of Abuse in serum

What is the hazard signal word for Medidrug® DOA S?

The signal word is no signal word.

What is the physical form of Medidrug® DOA S?

Medidrug® DOA S is a solid with yellowish color. It has odourless odor.

What is Medidrug® DOA S used for?

For in vitro diagnostic use

What is the melting point of Medidrug® DOA S?

The melting point is Not applicable and the boiling point is 105°C.