NextSDS Logo
Safety Data Sheet EN

CHROMOL

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CHROMOL
Product Code
108899E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Stainless steel care. Spray and wipe manual process Floor cleaner. Manual process

Manufacturers & Suppliers

E

Ecolab Ltd.

manufacturer

David Murray John Building, UK-SN1 1NH Swindon, Wiltshire, England

+44 (0)1793 511221

Emergency Contacts

National advisory body/Poison Centre

0870 600 6266

Manufacturer/ Distributor/ Importer

01793 511221

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear proper protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Put on appropriate personal protective equipment.

Small spill

Dilute with water and mop up if water-soluble or absorb with an inert dry material and place in an appropriate waste disposal container.

Large spill

Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see section 13).

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble or absorb with an inert dry material

Materials: sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. If this product contains ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

Hands

No special recommendations.

Eyes

No special recommendations.

Respiratory

A respirator is not needed under normal and intended conditions of product use.

Skin/Body

Body protection (EN 14605): Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Other skin protection: Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless to light yellow
Colour Intensity
---
Form
---
Odor
Floral
Odor Threshold
Not applicable and/or not determined for the mixture.
Ph
6.9 to 7.1 [Conc. (% w/w): 100%]
Melting Point
Not applicable and/or not determined for the mixture.
Boiling Point
Not applicable and/or not determined for the mixture.
Flash Point
> 100°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable and/or not determined for the mixture.
Vapor Pressure
Not applicable and/or not determined for the mixture.
Vapor Density
Not applicable and/or not determined for the mixture.
Relative Density
0.84 to 0.86
Bulk Density
---
Density
---
Flammability
Not applicable and/or not determined for the mixture.
Upper Explosive Limit
Not applicable and/or not determined for the mixture.
Lower Explosive Limit
Not applicable and/or not determined for the mixture.
Explosive Limits
---
Auto Ignition Temperature
Not applicable and/or not determined for the mixture.
Decomposition Temperature
Not applicable and/or not determined for the mixture.
Solubility
Very slightly soluble in the following materials: cold water and hot water.
Partition Coefficient
Not applicable and/or not determined for the mixture.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Conclusion/Summary : Not determined for the mixture.

Not determined for the mixture.

12.2 Persistence and degradability

Conclusion/Summary : The total of the organic components contained in the product achieve > 60% BOD/COD or CO2 liberation, or > 70% DOC reduction in tests for ease of degradability - threshold values for 'readily degradable' (e.g. to OECD method 301).

The total of the organic components contained in the product achieve > 60% BOD/COD or CO2 liberation, or > 70% DOC reduction in tests for ease of degradability - threshold values for 'readily degradable' (e.g. to OECD method 301).

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

Conclusion/Summary : Not determined for the mixture.

Not determined for the mixture.

12.4 Mobility in soil

Soil/water partition : Not determined for the mixture. coefficient (Koc) Mobility : Not determined for the mixture.

Not determined for the mixture.

12.5 Results of PBT and vPvB assessment

PBT : Not applicable. vPvB : Not applicable.

The substance is not considered to be PBT or vPvB.

12.6 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimised wherever possible. Significant quantities of waste product residues should not be disposed of via the foul sewer but processed in a suitable effluent treatment plant.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Waste Codes

20 01 30 detergents other than those mentioned in 20 01 29 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

EU Regulation (EC) No. 1907/2006 (REACH)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CHROMOL?

The signal word is no signal word.

What is the physical form of CHROMOL?

CHROMOL is a liquid. with colourless to light yellow color. It has floral odor.

What is the solubility of CHROMOL?

Very slightly soluble in the following materials: cold water and hot water.

What is CHROMOL used for?

Stainless steel care. Spray and wipe manual process Floor cleaner. Manual process

What is the melting point of CHROMOL?

The melting point is Not applicable and/or not determined for the mixture. and the boiling point is Not applicable and/or not determined for the mixture..