Argon

CAS 7440-37-1
EC 231-147-0

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Argon
Chemical Name
Argon

Regulatory Identifiers

CAS Number
7440-37-1 Check regulations →
EC Number
231-147-0 Check regulations →

Identified Uses

Industrial and professional. Perform risk assessment prior to use Test gas/Calibration gas Purge gas, diluting gas, inerting gas Purging Laboratory use Use for manufacture of electronic/photovoltaic components Shield gas for welding processes Contact supplier for more information on uses

Manufacturers & Suppliers

M

Messer Tehnogas AD

national supplier

Banjicki put 62, 11090 Beograd Serbia

+38 111 353 7210

Emergency Contacts

Emergency Contact

+381(0) 11 360 8440

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Press. Gas (Comp.) H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P403 Store in a well-ventilated place

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Contains no other components or impurities which will influence the classification of the product.

Chemical Name CAS Number Concentration Hazardous
Argon EC: 231-147-0 7440-37-1 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped

Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

Skin contact

Adverse effects not expected from this product

Eye contact

Adverse effects not expected from this product

Ingestion

Ingestion is not considered a potential route of exposure

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray or fog

Unsuitable media

Do not use water jet to extinguish

Specific hazards

Exposure to fire may cause containers to rupture/explode

Instructions

Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. If leaking do not spray water onto container. Water surrounding area (from protected position) to contain fire. Move containers away from the fire area if this can be done without risk.

Firefighter Protection

Use self-contained breathing apparatus. Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Standard EN 469 - Protective clothing for firefighters. Standard - EN 659: Protective gloves for firefighters.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Try to stop release. Act in accordance with local emergency plan. Stay upwind.

Environmental

Try to stop release

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Do not breathe gas. Avoid release of product into atmosphere. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect cylinders from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating cylinder valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the cylinder contents. Suck back of water into the container must be prevented.

Storage

Observe all regulations and local requirements regarding storage of containers. Containers should not be stored in conditions likely to encourage corrosion. Containers should be stored in the vertical position and properly secured to prevent them from falling over. Keep container below 50°C in a well ventilated place.

Hygiene

The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product.

Fire prevention

Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate general and local exhaust ventilation. Systems under pressure should be regularly checked for leakages. Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities

Hands

Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk

Eyes

Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications

Respiratory

Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask

Skin/Body

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear

Environmental

None necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Gas
Physical State Data
gas
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
---
Odor
No odour warning properties
Odor Threshold
Odour threshold is subjective and inadequate to warn of overexposure
Ph
Not applicable
Melting Point
-189 °C
Boiling Point
-186 °C
Flash Point
Not applicable for gases and gas mixtures
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable for gases and gas mixtures
Vapor Pressure
Not applicable
Vapor Density
---
Relative Density
Not applicable
Bulk Density
---
Density
---
Flammability
Non flammable
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not applicable for inorganic gases
Solubility In Water
67.3 mg/l
Solubility In Fat
---
Molecular Weight
40 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions

Reactivity

No reactivity hazard other than the effects described in sub-sections below

Avoid

None under recommended storage and handling conditions (see section 7)

Incompatible

For additional information on compatibility refer to ISO 11114

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Assessment : No ecological damage caused by this product.

No ecological damage caused by this product.

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.2. Persistence and degradability

Assessment : No ecological damage caused by this product.

No ecological damage caused by this product.

12.3. Bioaccumulative potential

Assessment : No ecological damage caused by this product.

No ecological damage caused by this product.

12.4. Mobility in soil

Assessment : No ecological damage caused by this product.

No ecological damage caused by this product.

12.5. Results of PBT and vPvB assessment

Assessment : Not classified as PBT or vPvB

Not classified as PBT or vPvB

12.6. Other adverse effects

Effect on the ozone layer : None Effect on global warming : None

The substance has no known effect on the ozone layer or global warming.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

May be vented to atmosphere in a well ventilated place

Disposal

Do not discharge into any place where its accumulation could be dangerous

Waste Codes

16 05 05 Gases in pressure containers other than those mentioned in 16 05 04 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1006
Shipping Name
ARGON, COMPRESSED
Transport Class
2.2
Packing Group
Not applicable
ADR

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: Ensure there is adequate ventilation, Ensure that containers are firmly secured, Ensure cylinder valve is closed and not leaking, Ensure valve outlet cap nut or plug (where provided) is correctly fitted, Ensure valve protection device (where provided) is correctly fitted.

IMDG

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: Ensure there is adequate ventilation, Ensure that containers are firmly secured, Ensure cylinder valve is closed and not leaking, Ensure valve outlet cap nut or plug (where provided) is correctly fitted, Ensure valve protection device (where provided) is correctly fitted.

IATA

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: Ensure there is adequate ventilation, Ensure that containers are firmly secured, Ensure cylinder valve is closed and not leaking, Ensure valve outlet cap nut or plug (where provided) is correctly fitted, Ensure valve protection device (where provided) is correctly fitted.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Ensure all national/local regulations are observed.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Argon?

The signal word is warning.

What is the physical form of Argon?

Argon is a gas with colourless color. It has no odour warning properties odor.

What is Argon used for?

Industrial and professional. Perform risk assessment prior to use Test gas/Calibration gas Purge gas, diluting gas, inerting gas Purging Laboratory use Use for manufacture of electronic/photovoltaic components Shield gas for welding processes Contact supplier for more information on uses

What are the hazard statements for Argon?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of Argon?

The melting point is -189 °C and the boiling point is -186 °C.