Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
N-Acetyl-L-phenylalanine
Product Code
B23812

Regulatory Identifiers

CAS Number
2018-61-3 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

A

Avocado Research Chemicals Ltd.

manufacturer

Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom

+44 (0) 1524 850506

Emergency Contacts

Emergency Contact

001-800-227-6701

Emergency Contact

+32 14 57 52 11

Emergency Contact

001-201-796-7100

Emergency Contact

+32 14 57 52 99

CHEMTREC

001-800-424-9300

CHEMTREC

001-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
L-Phenylalanine, N-acetyl- EC: 217-959-8 2018-61-3 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from exposure, lie down. Remove to fresh air.

Skin contact

Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Clean mouth with water.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO₂). Dry chemical. Chemical foam.

Unsuitable media

No information available.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapors.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

See Section 12 for additional Ecological Information.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Materials: suitable containers

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Do not breathe dust.

Storage

Keep in a dry, cool and well-ventilated place. Keep container tightly closed.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

None under normal use conditions.

Hands

Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. (minimum requirement)

Eyes

Wear safety glasses with side shields (or goggles) (European standard - EN 166)

Respiratory

No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation

Skin/Body

Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Powder Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Off-white
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No data available
Ph
No information available
Melting Point
165 - 167 °C / 329 - 332.6 °F
Boiling Point
No information available
Flash Point
No information available Method - No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
No data available
Vapor Density
Not applicable Solid
Relative Density
---
Bulk Density
No data available
Density
No data available
Flammability
Not applicable Solid
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
No information available
Solubility In Fat
---
Molecular Weight
207.23
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

No information available.

Avoid

Incompatible products.

Incompatible

Strong oxidizing agents.

Decomposition

Carbon monoxide (CO). Carbon dioxide (CO₂).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Ecotoxicity effects Contains no substances known to be hazardous to the environment or that are not degradable in waste water treatment plants.

Contains no substances known to be hazardous to the environment or that are not degradable in waste water treatment plants.

12.2. Persistence and degradability

No information available

12.3. Bioaccumulative potential

No information available

12.4. Mobility in soil

No information available

12.5. Results of PBT and vPvB assessment

No data available for assessment.

No data available for assessment.

12.6. Endocrine disrupting properties

Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors

This product does not contain any known or suspected endocrine disruptors.

12.7. Other adverse effects

Persistent Organic Pollutant Ozone Depletion Potential This product does not contain any known or suspected substance This product does not contain any known or suspected substance

The product does not contain any known or suspected substances related to Persistent Organic Pollutants or Ozone Depletion Potential.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. Consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.

Disposal

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Safety, health and environmental regulations/legislation specific for the substance or mixture

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for N-Acetyl-L-phenylalanine?

The signal word is no signal word.

What is the physical form of N-Acetyl-L-phenylalanine?

N-Acetyl-L-phenylalanine is a powder solid appearing as off-white . It has odorless odor.

What is N-Acetyl-L-phenylalanine used for?

Laboratory chemicals.

What is the melting point of N-Acetyl-L-phenylalanine?

The melting point is 165 - 167 °C / 329 - 332.6 °F and the boiling point is No information available.