Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Split Vent Cartridge
Product Code
5188-6495, G1544-80530

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Analytical chemistry. Sealed cartridge ( 3 ml ) 0.75 g

Manufacturers & Suppliers

A

Agilent Technologies, Inc.

manufacturer

5301 Stevens Creek Blvd Santa Clara, CA 95051, USA

800-227-9770

Emergency Contacts

CHEMTREC®

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Self-heat. Cat. 2 H252

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H252 Self-heating in large quantities; may catch fire.

Precautionary Statements

P407 Maintain air gap between stacks or pallets.
P413 Store bulk masses greater than 0.75 kg/1.65 lbs at temperatures not exceeding 40 °C/104 °F.
P420 Store separately.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

This article, when used under reasonable conditions and in accordance with the directions for use, should not present a health hazard. The substance or mixture is encapsulated in the article. Only if released due to use or processing of the article in a manner not in accordance with the product's directions for use it may present potential health and safety hazards.

Chemical Name CAS Number Concentration Hazardous
Carbon, Activated 7440-44-0 100% No

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: Exposure to airborne concentrations above statutory or recommended exposure limits may cause irritation of the nose, throat and lungs. Adverse symptoms may include the following: respiratory tract irritation, coughing.

Skin contact

Wash contaminated skin with soap and water. Remove contaminated clothing and shoes.

Symptoms: No known significant effects or critical hazards. No specific data.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses.

Symptoms: Exposure to airborne concentrations above statutory or recommended exposure limits may cause irritation of the eyes. Adverse symptoms may include the following: irritation, redness.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.

Symptoms: No known significant effects or critical hazards. No specific data.

Immediate Medical Attention

Get medical attention if irritation occurs (eye contact). Get medical attention if symptoms occur (skin contact).

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Self-heating material when in large quantities. May catch fire. May form explosive dust-air mixture if dispersed.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing dust.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Move containers from spill area. Vacuum or sweep up material and place in a designated, labeled waste container.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing dust. May form explosive dust-air mixture if dispersed. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Eliminate all ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Engineering controls may be required to control the primary or secondary risks associated with this product. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields. If operating conditions cause high dust concentrations to be produced, use dust goggles.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Solid.
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Solid.
Colour
Black.
Colour Intensity
---
Form
---
Odor
Odorless.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
>500°C (>932°F)
Boiling Point
4000°C (7232°F)
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
1.8 to 3.51
Bulk Density
---
Density
1.78 g/cm³ [25°C (77°F)]
Flammability
Flammable in the presence of the following materials or conditions: open flames, sparks and static discharge and heat. May catch fire.
Upper Explosive Limit
Not applicable.
Lower Explosive Limit
Not applicable.
Explosive Limits
---
Auto Ignition Temperature
<200°C (<392°F) [UN N.4]
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
0 g/l [OECD 105]
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

This product, by reaction with air and without energy supply, is liable to self-heat and will ignite when in large amounts and after long periods of time. The spontaneous ignition temperature will be ≤ 50°C for a volume of 27 m³.

Hazardous reactions

Hazardous reactions or instability may occur under certain conditions of storage or use. Conditions may include the following: extended contact with air in bulk storage Reactions may include the following: risk of causing fire spontaneous flammability

Avoid

No specific data.

Incompatible

May react or be incompatible with oxidizing materials.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | | Carbon, Activated | Acute LC50 >100 mg/l Fresh water | Fish | 96 hours |

12.2 Persistence and degradability

Not available.

12.3 Bioaccumulative potential

Not available.

12.4 Mobility in soil

Soil/water partition coefficient (Koc) : Not available.

12.5 Other adverse effects

: No known significant effects or critical hazards.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Split Vent Cartridge?

The signal word is warning.

What is the physical form of Split Vent Cartridge?

Split Vent Cartridge is a solid. appearing as solid. with black. color. It has odorless. odor.

What is Split Vent Cartridge used for?

Analytical chemistry. Sealed cartridge ( 3 ml ) 0.75 g

What are the hazard statements for Split Vent Cartridge?

This substance has 1 hazard statement:

  • H252: Self-heating in large quantities; may catch fire.

What is the melting point of Split Vent Cartridge?

The melting point is >500°C (>932°F) and the boiling point is 4000°C (7232°F).