Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ADP Reagent
- Product Code
- 101312
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
IVD In vitro diagnostic reagent used in light transmission platelet aggregation testing.
Manufacturers & Suppliers
Bio/Data Corporation
manufacturer
155 Gibraltar Road, Horsham, PA 19044 USA
+1 215-441-4000
http://www.biodatacorp.com
Emergency Contacts
Emergency Contact
+1 215-441-4000
Monday–Friday, 8:30 AM – 5:00 PM EST
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Adenosine-5’-diphosphate Sodium Salt | 20398-34-9 | --- | No |
| Sodium Chloride EC: 231-598-3 | 7647-14-5 | 0.85% | No |
| Water, Purified (Reagent Grade) EC: 231-791-2 | 7732-18-5 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Not an expected route of exposure.
Wash with water. Seek medical attention if irritation persists.
Rinse cautiously with water. Seek medical attention if needed.
Rinse mouth. Seek medical attention if symptoms occur.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, CO₂, dry chemical, or foam.
Non-flammable.
Firefighter Protection
Standard chemical fire PPE.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid runoff and prevent discharge into waterways.
Absorb with inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use per standard laboratory practice. Avoid contamination. Reconstitute the ADP Reagent using purified water.
Upon receipt, store at 2–8 °C in original packaging. Once reconstituted, the reagent is stable for 30 days in a tightly capped vial at 2–8 °C. Avoid light and repeated freeze-thaw cycles.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area or within a biosafety cabinet as appropriate.
Laboratory gloves (e.g., nitrile or latex)
Safety goggles or face shield
Not required under normal use conditions
Standard laboratory coat
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions.
No known reactivity hazards under normal conditions.
No hazardous polymerization or decomposition expected.
Excessive heat, light exposure, or repeated freeze-thaw cycles.
Strong oxidizing agents
None under normal use
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Persistence and Degradability
Bioaccumulation Potential
Mobility in Soil
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other Adverse Effects
Ecotoxicity
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of unused reagent and contaminated packaging in accordance with local, regional, or national regulations. Follow procedures for laboratory chemical disposal.
Dispose of unused reagent in accordance with local, regional, or national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
CE-marked under Regulation (EU) 2017/746. Product is exempt from REACH and TSCA requirements. Not classified as hazardous under CLP or OSHA HCS.
This SDS supports documentation requirements for ISO 15189 and ISO 17025 accredited laboratories. UKAS accreditation does not apply directly to SDS content. Complies with FDA Quality Management System Regulation (21 CFR Part 820).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ADP Reagent?
The signal word is no signal word.
What is the physical form of ADP Reagent?
ADP Reagent is a reagent: lyophilized cake/pellet; reconstituted reagent: liquid appearing as reagent (lyophilized): white lyophilized cake/pellet; reconstituted reagent: clear, colorless . It has odorless odor.
What is the solubility of ADP Reagent?
Soluble in water
What is ADP Reagent used for?
IVD In vitro diagnostic reagent used in light transmission platelet aggregation testing.
What is the melting point of ADP Reagent?
The melting point is Not applicable and the boiling point is Not applicable.