Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMA THINNER 90-53
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
solvent based, paint thinner
Manufacturers & Suppliers
SigmaKalon
manufacturer
Tweemontstraat 104, 2100 Deurne-Antwerpen
+32 3 3606311
Emergency Contacts
Emergency Contact
+31 20 4075210
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| xylene EC: 215-535-7 | 1330-20-7 | 25 - 50% | Yes |
| ethylbenzene EC: 202-849-4 | 100-41-4 | 10 - 25% | Yes |
| 1-methoxy-2-propanol EC: 203-539-1 | 107-98-2 | 25 - 50% | Yes |
| 2-methoxypropanol EC: 216-455-5 | 1589-47-5 | 0.1 - 0.5% | Yes |
Notes
If multiple components with identical identifiers appear, these have different hazardous properties, e.g. flashpoint.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep patient warm and at rest. If breathing is irregular or stopped, administer artificial respiration. If unconscious place in recovery position and seek medical advice.
Take off all contaminated clothing immediately. Wash skin thoroughly with soap and water or use recognized skin cleanser. Do NOT use solvents or thinners.
Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart. Remove contact lenses. Seek medical advice.
If accidentally swallowed obtain immediate medical attention. Keep at rest. Do NOT induce vomiting.
Immediate Medical Attention
Seek medical advice if symptoms persist or in all cases of doubt. If accidentally swallowed obtain immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Keep containers and surroundings cool with water spray.
Do NOT use water jet.
As the product contains combustible organic components, fire will produce dense black smoke containing hazardous products of combustion (see section 10). Exposure to decomposition products may be a hazard to health.
Cool closed containers exposed to fire with water spray.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Ventilate the area. Refer to protective measures listed in sections 7 and 8. Wear respiratory protection. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Try to prevent the material from entering drains or water ways. If the product contaminates rivers and lakes or drains inform respective authorities.
Clean with detergents. Avoid solvents. Contain and collect spillage with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
Materials: detergents, non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid exceeding of the given occupational exposure limits. Use only in area provided with appropriate exhaust ventilation. Avoid contact with skin, eyes and clothing. Smoking, eating and drinking should be prohibited in the application area. Avoid inhalation of vapour or mist.
Store between 5 and 25°C (41 - 77 F) in a dry, well ventilated place away from sources of heat, ignition and direct sunlight. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Smoking, eating and drinking should be prohibited in the application area.
Prevent the creation of flammable or explosive concentrations of vapour in air. When transferring from one container to another apply earthing measures and use conductive hose material. No sparking tools should be used. Take necessary action to avoid static electricity discharge. The product should only be used in areas from which all naked lights and other sources of ignition have been excluded. No smoking. Good housekeeping standards, regular safe removal of waste materials and regular maintenance of spray booth filters will minimise the risks of spontaneous combustion.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Minimum ventilated air quantity for 1 liter of product: TO REACH 10 % LEL : 184 m3/l
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Keep away from oxidising agents, strongly alkaline and strongly acid materials in order to avoid exothermic reactions.
Avoid temperatures above 60°C (140 F), direct sunlight and contact with sources of heat.
oxidising agents, strongly alkaline and strongly acid materials
In case of fire hazardous decomposition products may be produced such as: Carbon dioxide (CO2), carbon monoxide (CO), oxides of nitrogen (NOx), dense black smoke.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The product should not be allowed to enter drains, water courses or the soil. Disposal together with normal waste is not allowed. Special disposal required according to local regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT RELATED MATERIAL
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is classified and labelled in accordance with Directive 1999/45/EC. The information contained in this safety data sheet does not constitute the user's own assessment of workplace risks, as required by other health and safety legislation. The provisions of the national health and safety at work regulations apply to the use of this product at work.
R-phrase(s): R10, R20/21, R38. S-phrase(s): S 2, S23, S36/37, S38, S46.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SIGMA THINNER 90-53?
The signal word is na: r-phrases.
What is the physical form of SIGMA THINNER 90-53?
SIGMA THINNER 90-53 is a liquid with colourless color. It has hydrocarbon-like strong odor.
What is SIGMA THINNER 90-53 used for?
solvent based, paint thinner